Records from 2016 to 2026. Most recent: inspection, 24 March 2026.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 14.0 ft × 3.1 ft
Registered tonnagegross 49 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAMERICAN REDI-BILT · COLUMBIA · built 2010
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portOCEAN CITY, MD
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 September 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it49 - Simplified, Gross Ton
49 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
24 March 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8331648
11 February 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8309241
18 September 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8237337
24 September 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8011765
18 June 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7937500
27 February 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7873637
28 September 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7800500
27 September 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7567768
11 March 2022
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7411254
9 August 2021
COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7128473
30 September 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7069352
20 February 2020
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6926079
27 August 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6797535
3 October 2018
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6547575
1 March 2018
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6375677
28 August 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6484148
8 August 2017
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6242592
11 August 2016
COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5994396
22 March 2016
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5838306
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 27 February 2024
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Lloyd's Yachts and Small Craft. Cracked and damaged steps #3, #4, and #5 towards the upper deck. Identified steps need to be repaired.
46CFR177.300(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2024
Resolved 13 May 2024
Resolution: All steps were repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 27 February 2024
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. The point and uniform loads do not need to be applied simultaneously.
46CFR177.900(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2024
Resolved 13 May 2024
Resolution: All railings were repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 August 2021
Resolved
Each portable fire extinguisher on a vessel must be of an approved type and minimum number required by the [name withheld] type extinguishers on vessel (03)10-B:C, (01)3-A:60-B:C. Missing (02) 2-A.
46 CFR 181.500(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2021
Resolved 10 August 2021
Resolution: Received proof of purchase of new portable fire extinguishers, (01) 10-B:C, (03) 3-A:60-B:C.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 9 August 2021
Resolved
Rail courses or the equivalent must be installed between top rail and the deck so that no opening space exists that is more than 12 inches high. No courses insalled in bow railing, 39" gap between top rail and deck.
46 CFR 177.900(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2021
Resolved 27 August 2021
Resolution: O/O fabricated removable railing of adequate height with gaps no larger than 4 inches between courses.