MAURY USCG vessel records Sign in
← All vessels

BUNGA ALAMANDA

BUNGA ALAMANDA is a tank ship. The Coast Guard has recorded 1 inspection in 2018, along with 2 deficiencies.

Records in 2018. Most recent: inspection, 18 July 2018.

Built
Not recorded
Last inspected
18 July 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9389502 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1098839
Flag
MALAYSIA
—
Maury page id
psix-1098839

Inspections, by type

Years with a record 1 calendar year (2018)
The 1 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it25709 - Regulatory (Subpart C or D), Gross Ton
38005 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 1

18 July 2018 ISPS II Exam · Ballast Water Examination · COC-CHEM Annual
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6476791

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 July 2018 Resolved
The number an position of monitors shall be capable of delivering foam to the entire cargo tanks deck area. Fire monitor above tank (slop) inoperable. Station #1. Site: Solas 09 II-2/10.8.1.1 FSS Code 14/2.3.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2018
Resolved 20 July 2018
Resolution: Fire monitor was repaired. Class surveyor attested to repairs. See documents tab for more information.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 July 2018 Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors that are stiffened and fitted so that they are weathertight when closed. Starboard side superstructure entrance to number 1 deck not weather tight. Site: ICLL 66 Reg 12(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2018
Resolved 20 July 2018
Resolution: Door was repaired. Class surveyor attended vessel and confirmed repairs. See documents tab for more details.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.