PRAIRIE DU ROCHER

PRAIRIE DU ROCHER is a 2002 towing vessel. The Coast Guard has recorded 7 inspections since 2010, most recently in March 2026, along with 20 deficiencies.

Records from 2010 to 2026. Most recent: inspection, 2 March 2026.

Built
2002
Last inspected
2 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

1098978
Flag
UNITED STATES
Maury page id
psix-1098978

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspections, by type

…with no type recorded1
Years with a record 6 calendar years (2010–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it55 - Simplified, Gross Ton
37 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 7

2 March 2026 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8297092
5 March 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8076186
26 February 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7870123
4 May 2023 Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7681926
15 March 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7640746
23 June 2021 Initial Certification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7163600
10 September 2010 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3869819

Deficiency record · 20

04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 5 March 2025 Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crew members are capable of performing the duties expected of them during emergencies. This includes abandoning the vessel, recovering persons from the water, responding to on board fires and flooding, or responding to other threats to life, property, or the environment. Vessel and crew were not up to date on all drills. Conduct and document drills in accordance with 46 CFR 140.420.
Action required: 10 - Deficiency Rectified
Due 5 March 2025
Resolved 14 April 2025
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 March 2025 Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. Test and examination procedures must be in accordance with manufacturer's instructions. There were no records for readiness and testing. Prove required testing is being conducted in accordance with 46 CFR 143.245(b).
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 14 April 2025
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 15 March 2023 Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. Lagging missing from both MDEs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 4 May 2023
Resolution: Lagging on both MDEs was re-installed.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 15 March 2023 Resolved
General alarm (and alternative as described in 46 CFR 143.235(b)(4)) must have a sign that reads: “Attention General Alarm - When Alarm Sounds or Flashes Go to Your Station”. Sign was missing in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 4 May 2023
Resolution: Proper signage posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 March 2023 Resolved
Each life buoy must be marked in block capital letters with the name of the vessel. The lifebuoy located on the starboard side of the pilot house was missing the vessel's name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 4 May 2023
Resolution: Each life buoy properly marked.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 26 June 2021 Resolved
Testing required for main propulsion engines and generator engines (high temperature and low lube oil pressure alarm set points) and low hydraulic steering fluid level. Testing not performed. Perform testing in presence of a USCG Marine Inspector and record in Towing Vessel Record.
Action required: 705 - Other - as specified
Resolved 20 December 2021
Resolution: All sensors checked in presence of a marine inspector; repairs identified were completed and verified by vessel captain who provided report to marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2021 Resolved
Lifebuoy water light required to have lanyard between three and six feet in length, attached around the body of the buoy. Three of the vessel's four water lights were attached with lanyards less that three feet attached to the lifebuoy's grab line. Properly attach water lights to ring buoys.
Action required: 705 - Other - as specified
Resolved 28 September 2021
Resolution: Lifebuoys fitted with proper length waterlight lanyards.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 June 2021 Resolved
Fire detection system is required identify origin of fire. Display panel identified the wrong location of all sensors when tested. Prove proper operation of system.
Action required: 705 - Other - as specified
Resolved 28 September 2021
Resolution: Fire detection control panel displayed the correct information concerning the location of the activated sensor.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 June 2021 Resolved
The design of the fire detection system and its installation on the towing vessel is certified and inspected by a PE, NICET technician, or Authorized Classification Society. Documentation not available for exam. Provide documentation for exam.
Action required: 705 - Other - as specified
Resolved 16 November 2021
Resolution: Vessel rep provided satisfactory documentation showing system certified by PE.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2021 Resolved
Lifebuoy required to be marked with vessel name. One lifebuoy not marked with vessel's name, stencil worn off. Properly re-stencil lifebuoy.
Action required: 705 - Other - as specified
Resolved 28 September 2021
Resolution: All lifebuoys properly marked with vessel's name.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 23 June 2021 Resolved
Fuel shutoff required to operate remotely in the event of a fire or break in the fuel line. Access to remotely operated valve blocked by cap requiring special tool; valve was not exercised during inspection. Special tool was missing from vessel. Prove access and proper operation of remote valve.
Action required: 705 - Other - as specified
Resolved 28 September 2021
Resolution: Emergency fuel shut off valve accessible and crew proved proper operation.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 June 2021 Resolved
All machinery vents required to have means to close. Vessel was not fitted with means to close four of six machinery space vents (located on each stack and either side of compressor room). Properly outfit vessel with means to close all machinery space vents.
Action required: 705 - Other - as specified
Resolved 28 September 2021
Resolution: Crew made internals of machinery space vents (four) available for inspection to show vents are fitted with closure devices.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 June 2021 Resolved
Vessel engine room/tank room is equipped with two means of escape. Forward means of escape (WT hatch to main deck) missing handle to open. Prove proper operation of hatch.
Action required: 705 - Other - as specified
Resolved 28 September 2021
Resolution: Handle was re-connected and hatch function properly.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 23 June 2021 Resolved
Engine/bilge/hydraulic steering alarms required to be audible. Audible alarm failed to function during inspection. Prove proper operation of audible alarms.
Action required: 705 - Other - as specified
Resolved 28 September 2021
Resolution: Crew proved proper operation of high level bilge alarm and low level hydraulic alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 June 2021 Resolved
Vessel fitted with installed bilge dewatering system. Forepeak bilge pick up failed to evacuate water. Prove proper operation of bilge system.
Action required: 705 - Other - as specified
Resolved 28 September 2021
Resolution: Crew proved proper operation of the forepeak bilge system pickup.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 23 June 2021 Resolved
Each integral fuel tank must have a vent fitted with a 30-by-30-mesh corrosion-resistant flame screen. Fuel tank vent flame screen was damaged. Repair or replace vent flame screen.
Action required: 705 - Other - as specified
Resolved 28 September 2021
Resolution: Fuel tank vent properly fitted with new flame screen.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 June 2021 Resolved
Auxiliary generator engines must be equipped with an RPM gauge at the machinery location. The vessel's generators were not equipped with RPM gauges. Properly install RPM gauges for each generator engine at machinery location.
Action required: 705 - Other - as specified
Resolved 17 December 2021
Resolution: Electronic RPM guage installed for both generators.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 June 2021 Resolved
Portable fire extinguishers are required to be inspected or tested once every 12 months IAW 46CFR142.240(a). One CO2 portable fire extinguisher not tested/inspected annually. Extinguisher removed from vessel.
Action required: 10 - Deficiency Rectified
Resolved 23 June 2021
Resolution: Extinguisher removed from vessel.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 23 June 2021 Resolved
Illuminated magnetic compass required on vessel. Vessel not equipped with a magnetic compass. Install an illuminated magnetic compass (or swing meter) at the operating station.
Action required: 705 - Other - as specified
Resolved 28 September 2021
Resolution: Operator's station fitted with illuminated magnetic compass.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 June 2021 Resolved
Vessel required to be operated in a manner to afford protection against hazards to the environment. A small amount of hydraulic fluid leaked from port steering hydraulic ram on to the stern deck of the vessel. Clean fluid and properly repair steering ram.
Action required: 705 - Other - as specified
Resolved 17 November 2021
Resolution: New hydraulic ram installed.