MAURY USCG vessel records
← All vessels

MSC TOKYO

MSC TOKYO is a 2006 freight ship. The Coast Guard has recorded 8 inspections since 2016, most recently in June 2024, along with 3 deficiencies and 2 operational controls.

Records from 2016 to 2024. Most recent: inspection, 10 June 2024.

Built
2006
Last inspected
10 June 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 June 2024
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9318046
1099090
Flag
LIBERIA
Maury page id
psix-1099090

Documentation record

Tonnage as PSIX records it91649 - Convention (Subpart B), Gross Ton
56693 - Convention (Subpart B), Net Ton
103200 - Dead Weight, Metric Ton
137070 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

10 June 2024 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7931811
10 November 2023 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7822700
9 August 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7764355
8 March 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7647441
5 March 2023 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7644425
1 March 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7643728
16 August 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6242408
16 August 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5968515

Deficiency record · 3

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 1 March 2023 Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the administration...A second source of energy shall be provided for an additional three starts within 30 min unless manual starting can be demonstrated to be effective. During emergency generator test, PSCO observed secondary means of starting fail to start emergency generator.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2023
Resolution: Sector New York received a Flag report attesting to the secondary means to start the emergency generator being fixed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 16 August 2017 Resolved
Def Code: 0720 Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization. Fire extinguishers were not tested during the month of July in accordance with the ships safety management system. SOLAS 74 (2014 CONS.) II-2/14.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 16 August 2017
Resolution: 10C
Documentation › Logs/Records › Logbook (official)
Issued 16 August 2017 Resolved
Def Code: 0696 Inspection of life saving appliances shall be carried out monthly. A report of the inspection shall be entered in the log book. PSCO observed no monthly inspection of EPIRB and SART. SOLAS 74 (2014 CONS.) III/20.7.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 16 August 2017
Resolution: 10C

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.