Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it60578 - Convention (Subpart B), Gross Ton 106992 - Dead Weight, Metric Ton 125881 - Displacement, Metric Ton 33762 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
7 inspections, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 7
27 May 2022PSC B · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7460107
4 May 2021COC-TVE Annual · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7188921
3 May 2020PSC B · COC-TVE Renew
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6933102
21 April 2020Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 6941933
18 April 2020In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6941039
6 April 2020COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6935851
17 July 2016ISPS II Exam · Deficiency Check · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5936918
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 27 May 2022Resolved
Personnel responsible for the operation of an incinerator shall be trained to implement the guidance provided in the manufacturer's operating manual. Refractory brick on both incinerators was severely deteriorated and missing large chunks around the perimeter of the doors. MARPOL VI/16.6.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2022
Resolved 28 May 2022
Resolution: Operator sent satisfactory evidence of fixed areas around deteriorated door.
Deck/Cargo › Inert Gas System › Venting System
Issued 17 July 2016Resolved
74SOLAS09Cons CHII-2 reg 4.5.5.1.2FSS Code CH15.2.3.2.5- Tankers operating with a cargo tank cleaning procedure using crude oil washing shall be fitted with an inert gas system complying with the FSS Code. Piping systems shall be so designed as to prevent the accumulation of cargo or water in the pipelines under all normal conditions. Main IG line is leaking water due to pinholes in 04 bellows.60a
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2016
Resolved 19 July 2016
Resolution: Vessel completed temp repair approved by class.
Fire Fighting › Fire Pumps › Bearings
Issued 17 July 2016Resolved
74SOLAS 09CONS CHII-2 Reg14.2.1.2 - Firefighting systems and appliances shall be readily available for immediate use. Primary Fire/General service pump not functioning.17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2016
Resolved 19 July 2016
Resolution: Recieved class report attesting to repair of fire pump.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 17 July 2016Resolved
74SOLAS2014cons. CHI-11.a - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship will reamin fit to proceed to sea without danger of persons on board. #1S cargo tank sighting port not sealed due to damage from heavy weather. 60ac
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2016
Resolved 19 July 2016
Resolution: Recieved class report attesting to temporary repair.