GEM is a 2009 tank ship. The Coast Guard has recorded 9 inspections since 2012, most recently in March 2025, along with 1 deficiency and 2 operational controls.

Records from 2012 to 2025. Most recent: inspection, 17 March 2025.

Built
2009
Last inspected
17 March 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9406001 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1099126
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1099126

Inspections, by type

…with no type recorded2
Years with a record 6 calendar years (2012–2025)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it84160 - Convention (Subpart B), Gross Ton
49031 - Convention (Subpart B), Net Ton
156840 - Dead Weight, Metric Ton
182538 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 9

17 March 2025 COC-TVE Annual
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8087620
17 February 2024 COC-TVE Renew
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7856024
28 September 2022 COE-Offshore · PSC B · COC-TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7565174
22 September 2022 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7564774
18 March 2019 ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6644435
4 March 2016 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5826923
11 February 2016 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5812885
22 July 2012 ISPS II Exam · Ballast Water Examination · COC-TVE Annual · COE-Offshore
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4383551
21 July 2012 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4383553

Deficiency record · 1

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 17 March 2025 Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization. PSCO observed 03 cracked lights in the pumproom. 74SOLAS(20) II-1/ 45.11 34AC
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 March 2025
Resolved 17 March 2025