← All vessels
ALPINE LIBERTY
ALPINE LIBERTY is a 2010 tank ship. The Coast Guard has recorded 16 inspections since 2015, most recently in October 2024, along with 5 deficiencies and 2 operational controls.
Records from 2015 to 2024. Most recent: inspection, 13 October 2024.
- Built
- 2010
- Last inspected
- 13 October 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9478690 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7TT7
1099672
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1099672
Inspections, by type
…with no type recorded4
Years with a record
7 calendar years (2015–2024)
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it29826 - Convention (Subpart B), Gross Ton
13429 - Convention (Subpart B), Net Ton
60976 - Displacement, Ton
50223 - Dead Weight, Ton
13429 - Convention (Subpart B), Net Ton
60976 - Displacement, Ton
50223 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
13 October 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8017714
22 May 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7917293
3 April 2024
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7889267
15 March 2024
PSC B · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7878283
14 March 2024
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7880935
22 December 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7841752
10 March 2023
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7649010
5 December 2020
ISPS Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7106696
1 April 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6934176
30 September 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6824925
25 April 2019
COE-Dockside · ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6669928
25 July 2017
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6214504
24 July 2017
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6218846
19 July 2017
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6214569
8 January 2016
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5793580
22 December 2015
ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5784368
Deficiency record · 5
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 15 March 2024
Resolved
Any discharge into the sea of oil or oily mixtures from the cargo area shall be prohibited except when the instantaneous rate of discharge of oil content does not exceed 30 liters per nautifcal mile and the tanker has in operation an oil dicharge monitoring and control system. PSCO observed rate of dicharge during ODME operation in ORB Part II exceeding that of the ODME Records from the discharge.
MARPOL ANNEX I 34.1 / 16bc
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 15 March 2024
Resolved
The Oil Record Book Part II shall be completed when any of the following cargo operations take place; discharge of water from slop tanks. PSCO observed discharge entry for 74.884m3 but ODME records only approximatley 11.5m3 discharged per flow rate, leaving 63.3m3 unaccounted for. Similiar entries found for discharges on 03OCT2023, 14OCT2023, 10JAN2024.
MARPOL ANNEX I
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 15 March 2024
Resolved
The company should ensure that all personnel involved in the company's safety management system have an adequate understanding of relevant rules, regulations, codes, and guidelines. On completion of tank cleaning operations, as much slop shall be decanted as is possible in full compliance with MARPOL and company's environmental policies, allowing the washings to settle at least 24 hours... (SMS/Management System 06-Cargo and Ballast Operations). All diligence must be carried out in ensuring the accuracy and completeness of entries in the Oil Record Book (SMS/Marine Guideline No.2-13-3). As delineated in deficiencies 1-2, the company failed to ensure that all personnel involved in the companies SMS had adequate understanding of the relevant rules, regulations, codes,and guidelines. An additional internal verification of the vessel's SMS, focusing on record keeping, ODME operation, and discharge operations is required.
74SOLAS(20)IX/3.1 ISM CODE 6.4 50bc
Lifesaving › Launching Appliances › Hand Gear
Issued 22 December 2015
Resolved
0630 - Launch arrangt for survival craft - Hand gear handles or wheels shall not be rotated by moving parts of the winch when the survival craft or rescue boat is being lowered or when it's being hoisted by power. PSCO observed no positive means of disabling power to electrical winch when hand crank was engaged. 74 SOLAS 14 con. III/34 & LSA 6.1.2.6
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 22 December 2015
Resolved
0715 - Detection - The vessel shall maintain and monitor the effectiveness of fire safety systems and functional requirements shall be met with all fire protection systems and firefighting systems ready for use. PSCO observed inoperable gas detection (fixed) system and no annual calibration certificate. 74 SOLAS 04 con. II-2/14.1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.