Records from 2017 to 2025. Most recent: inspection, 6 October 2025.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 6 January 2017
Resolved
Stairways which penetrate single decks or more than single decks will be protected by self-closing doors. The boundary door to steering and the emergency escape (lower level of engine room) door have had their self closing devices removed (evident from holes in door frame). 2004 SOLAS Cons. Chpt II-2/9.2.3.4.1. 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 February 2017
Resolved 8 June 2017
Resolution: PSC HOU-GAL received report from Class NKK satisfying the requirements.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 6 January 2017
Resolved
Doors fitted in boundary bulkheads of machinery spaces of CAT A chall be self closing. The engine room to provisions flat door and the control room to work space door closure does not work properly and is removed respectfully (evident from holes in door and frame).
2004 SOLAS Cons Chpt II-2/9.4.2.1. 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 February 2017
Resolved 8 June 2017
Resolution: PSC HOU-GAL received report from Class NKK satisfying the requirements.
Electrical › Electric Generation Source (emergency) › Metallic Enclosure/Frame
Issued 6 January 2017
Resolved
Electrical installations shall be such that the safety of the crew and ship are protected from electrical hazards. One set of E-Gen batteries are secured in a temporary manner and not protected.
2009 SOLAS Cons. Chpt II-I/40.1.3. 40ac
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 February 2017
Resolved 8 June 2017
Resolution: PSC HOU-GAL received report from Class NKK satisfying the requirements.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 January 2017
Resolved
Oil filtering equipment shall comply with Para. 6. There is a leak on a pressure line toward the OCM.
MARPOL ANNEX I/14.7. 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 February 2017
Resolved 8 June 2017
Resolution: PSC HOU-GAL received report from Class NKK satisfying the requirements.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 6 January 2017
Resolved
Fire protection systems shall be maintained and ready for use. The heat detector in the E.R. work space was concealled with rags. Unit was tested.
2014 SOLAS Cons. Chpt. II-2/14.1. 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 6 January 2017
Resolution: Deficiency rectified prior to the conclusion of the inspection.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 January 2017
Resolved
Lifebuoys shall be in compliance with LSA Code. Shall be fitted with retro-relfective material. 06 lifebuoys and multiple areas on lifeboats have retro that is peeling and faded.
2014 SOLAS Cons. Chpt III/7.1.3 LSA Code Chpt 1.2.2.7. 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 6 January 2017
Resolution: Deficiency rectified prior to the conclusion of the inspection.