KODAIJISAN

KODAIJISAN is a 2003 tank ship. The Coast Guard has recorded 6 inspections since 2017, most recently in June 2026, along with 5 deficiencies.

Records from 2017 to 2026. Most recent: inspection, 11 June 2026.

Built
2003
Last inspected
11 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 June 2026
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9249049
1099732
Flag
PANAMA
Maury page id
psix-1099732

Documentation record

Tonnage as PSIX records it47046 - Regulatory (Subpart C or D), Gross Ton
17178 - Regulatory (Subpart C or D), Net Ton
47046 - Convention (Subpart B), Gross Ton
17178 - Convention (Subpart B), Net Ton
58591 - Dead Weight, Ton
77523 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 6

11 June 2026 PSC B · COC-GAS Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8387797
28 February 2025 COC-GAS Renew · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8083502
25 July 2023 PSC B · COC-GAS Renew · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7749688
3 July 2020 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6990255
14 March 2019 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6642012
14 December 2017 Deficiency Check · COC-GAS Renew · ISPS II Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6323006

Deficiency record · 5

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2025 Resolved
No. 01 Code 09209 10.2.5.1 In zones on open decks or non-enclosed spaces on the open deck, within 3M of any cargo tank outlet, gas or vapor outlet, cargo pipe flange, cargo com pressor rooms; .1 certified safe type equipment;and .2 through runs of cables PSCO observed approximately 05 lights in cargo compressor room with improperly installed wiring and missing ground wires. Additionally all remote valve indicators are installed in such a way that operation of cargo valves causes damage to indicator wiring. PSCO observed broken packing nuts and damaged wiring on 50% of cargo valves.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2025
Resolved 28 February 2025
Resolution: Provided class survey and Master's attestation stating satisfactory measures were taken to isolate power to remote valves until permanent repairs are complete.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 14 December 2017 Resolved
1850- Fire protection cargo deck. On ships carrying flammable or toxic products or both, a water spray system for cooling fire prevention and crew protection should be installed to cover exposed cargo tank domes and any exposed parts of cargo tanks. Cargo tank 1 tank dome is not fully covered by deck water spray, in addition, starboard side motor and compressor room is not adaquately covered. 01 water nozzle on port manifold is clogged. 74SOLAS(2014 cons) VII/13.1; IGC Code 11.3.1 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2017
Resolution: PSC HOU received class NKK report satisfying the requirements.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 December 2017 Resolved
0520- Lighting-working spaces. Electrical installations should be such as to minimize the risk of fire and explosion from flammable products. Port state control officers observed 02 deck lights in the cargo area that did not appear to be gas safe. Both lights had foreign debris built up inside the casing. 74SOLAS(2014 cons)VII/13.1; IGC Code 10.1.2 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2017
Resolution: PSC HOU received class NKK report satisfying the requirements.
Engineering › Steering Gear System › Follow-up Assembly
Issued 14 December 2017 Resolved
1510- Navigation equipment. Steering gear control shall be provided where the main steering gear is arranged in accordance with Paragraph 6, by two independent control systems, both operable from the navigation bridge. #2 main stearing gear pump does not work in non-follow up mode when operated from the bridge. 74SOLAS(2004)II-I/27.7.2 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2017
Resolution: PSC HOU received class NKK report satisfying the requirements.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 14 December 2017 Resolved
1730- Oily water separating equipment. The system shall be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15ppm. Crew could not demonstrate proper operation of oily water separator and oil content meter. MARPOL ANNEX I/14.7 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2017
Resolution: PSC HOU received class NKK report satisfying the requirements.