BBC NAPLES is a 2010 freight ship. The Coast Guard has recorded 24 inspections since 2017, most recently in May 2025, along with 18 deficiencies and 4 operational controls, 1 with no removal date recorded.
Records from 2017 to 2025. Most recent: inspection, 30 May 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it6351 - Convention (Subpart B), Gross Ton 3617 - Convention (Subpart B), Net Ton 12837 - Displacement, Metric Ton 9822 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 24
30 May 2025PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8144965
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 21 October 2022Resolved
FIRE PROTECTION SYSTEMS AND FIRE FIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED READY FOR USE. PSCO WITNESSED A PIN INSERTED INTO CO2 CYLINDER, RENDERING IT INOPERABLE. [name withheld] UPON IDENTIFICATION.
74 SOLAS (20) 11-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 October 2022
Resolved 21 October 2022
Resolution: CORRECTED ON THE SPOT
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 October 2022Resolved
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT ALL ELECTRICAL AUXILARY SERVICES NECESSARY FOR MAINTAINING THE SHIP IN NORMAL OPERATIONAL AND HABITABLE CONDITIONS WILL BE ENSURED WITHOUT RECOURSE TO THE EMERGENCY SOURCE OF ELECTRICAL POWER. PSCO IDENTIFIED THE BACK OF THE MAIN ENGINE SWITCHBOARD IN THE ENGINE CONTROL ROOM WAS OFF AND HAD A FAN CRUDELY POSITIONED TO PREVENT OVER-HEATING.
74 SOLAS(09) II-I / 40.1.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2022
Resolved 23 October 2022
Resolution: Received class survey
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 October 2022Resolved
INTERNAL COMBUSTION ENGINES OF 2250KW AND ABOVE OR HAVING CYLINDERS OF MORE THAN 300MM BORE, SHALL BE PROVIDED WITH CRANK CASE OIL MIST DETECTORS. OIL MIST DETECTORS READ A "LOW AIR FLOW" ALARM AT ALL TIMES DURING INSPECTION. [name withheld] THIS IS STANDARD OPERATIONS FOR THE SHIP, WHICH IS CONTRADICTED IN SHIP'S SAFETY MANAGEMENT.
74 SOLAS (09) II-I/47.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2022
Resolved 23 October 2022
Resolution: Received class survey
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 October 2022Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO IDENTIFIED 02 LOCATIONS OF POOLING LUBE OIL COMING DIRECTLY FROM CONNECTION POINTS ON THE MAIN DIESEL ENGINE.
74 SOLAS(20) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2022
Resolved 23 October 2022
Resolution: Received class survey
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 21 October 2022Resolved
THE MACHINERY SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. PSCO IDENTIFIED MAIN ENGINE CRANK BEING EXPOSED WITHOUT A GUARD.
74 SOLAS(09) II-I/26.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2022
Resolved 23 October 2022
Resolution: Received class survey
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 22 August 2022Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company: Appropriate corrective action is taken.
As it relates to deficiency 02, the crew was originally questioned on the nature of oily water in the bilge well, and could not identify the source. It was later stated by the crew that the oily mixture was leaking from the main engine. 02 cookie cans were discovered in the bilge well intended to catch oil leaks, indicating that the crew was aware of the nature of the leaks prior to examination. Port State Control Officer (PSCO) also discovered oil mist detector (OMD) alarm activated on the main engine. Vessel's PMS stated that the crew should follow OMD's manufacturer instructions if alarms were activated. PSCO reviewed instructions and confirmed with the crew that instructions had not been followed when OMD alarm was received 03 times on 22AUG2022. PSCO also discovered the No. 2 generator disabled. The crew stated that the generator had been disabled due to a recurring alarm. Objective evidence exists for lack of corrective actions taken on deficient items and alarms discovered by the crew.
An external ISM audit is required with a focus on fire safety and engine room maintenance.
74 SOLAS (20) IX/3.1
ISM Code 10.1
30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 31 August 2022
Resolution: Vessel submitted Class Report attesting to proper repairs. Document uploaded.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 August 2022Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids.
PSCO discovered a flowing pool of oily water spanning half of the engine room bilge.
74 SOLAS (04) II-2/4.1.1
30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 31 August 2022
Resolution: Vessel submitted Class Report attesting to proper repairs. Document uploaded.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 22 August 2022Resolved
Every ship of 400 gross tonnage and above shall be provided with a tank or tanks of adequate capacity. having regard for to the type of machinery and length of voyage, to receive the oil residues (sludge) which cannot be dealt with otherwise in accordance with the requirements of this Annex.
Vessel has 02 tanks listed on the IOPP Form A for collection of sludge: Sludge Tank and Dirty Oil Tank. The Sludge Tank has a capacity of 7.76 cubic meters, and the Dirty Oil Tank has a capacity of 10.01 cubic meters. 22AUG2022 sounding indicated the Sludge Tank level to be 6.99 cubic meters and th Dirty Oil Tank level to be 9.02 cubic meters. The crew stated that 0.2 cubic meters of sludge is generated per day. Vessel intends to transit to Panama after departing Houston.
73/78 MARPOL I/12.1
60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 August 2022
Resolution: Vessel submitted Class Report attesting to proper repairs. Document uploaded.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 August 2022Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of the fire-fighting systems and appliances.
PSCO observed 02 fire detectors in the engine room missing covers. PSCO observed the Chief Engineer replace a fallen cover onto one of the fire detectors, but the cover would not stay fastened, resulting in the cover falling off and breaking.
74 SOLAS (04) II-2/14.2.2.1
50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2022
Resolution: Vessel submitted Class Report attesting to proper repairs. Document uploaded.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 22 August 2022Resolved
A vessel equipped with ballast water tanks that operates in waters of the United States must maintain a ballast water management plan that has been developed specifically for the vessel and that will allow those responsible for the plan implementation to understand and follow the vessel's ballast water management strategy and comply with requirements of this subpart.
Vessel's ballast water management plan does not include all of the necessary provisions listed in 33 CFR 151 Subpart D. U.S. Regulations not identified.
33 CFR 151.2050(g)
50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2022
Resolution: Vessel submitted Class Report attesting to proper repairs. Document uploaded.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 August 2022Resolved
The master, owner, operator, agent, or persons in charge of a vessel subject to this part that is bound for ports and places in the United States outside of the Great Lakes or Hudson Rover must submit a ballast water report to NBIC no later than 06 hours after arrival at the port or place of destination. Vessel arrived at the dock at 1500 on 20AUG2022.
PSCO's boarded the vessel at 1100 on 22AUG2022, more than 06 hours after arrival. No NBIC report had been submitted.
33 CFR 151.2060(b)(3)
10c
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 6 August 2019Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the relevant roles and regulations and with any additional requirements which may be established by the company. In meeting these requirements the company should ensure that: any non-conformity is reported with its possible causes if known; and ensure appropriate corrective action is taken. A significant leak was found on the lube oil purifier that was being captured in a bucket, the smoke detector above it was operational but held in place with tape, and emergency escape and CO2 room were also found not to close properly. None of these items were reported to the company, low level hydraulic oil and power failure alarms for steering gear where inoperable and had not been tested or identified. Emergency diesel generator fuel cutoff was closed had not been identified rendering it unable to function in emergency. Operational deficiencies collectively provide objective evidence of a serious failure or lack of effectiveness of the implementation of ISM Code. An external audit is recommended to be conducted within 30 days by Flag State or RO. Provide decision to USCG prior to departure. -74SOLAS(14)IX/3.1 &ISM Code Part A 10 (17ABC)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2019
Resolution: The company has agreed to do a SMS audit of the vessel.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 6 August 2019Resolved
Where the emergency source of electrical power is a generator, it shall be: started automatically upon failure of the main source of electrical power supply…PSCO found the FO quick closing valve to be in the closed position, not allowing for the emergency generator to start and run in current state. Engineers were able to open the valve and test functionality in presence of PSCO. 74SOLAS(04) II-1/43.3.1 (10c)
Action required: 30 - Ship detained
Resolved 7 August 2019
Resolution: Emergency Diesel Generator fuel cutoff was reset into the open position.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 August 2019Resolved
The Ignitability of combustible material shall be restricted. Lube oil purifier has a leak in associated piping of one drop per second that is being captured in a bucket. 74SOLAS(04) II-2/4.1.3 60AC
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 August 2019
Resolution: Received a class report that confirmed that required drain hoses on both lube oil and fuel oil purifiers were replaced adn are now working as intended.
Hydraulic power operating steering gear shall be provided with... a low level alarm for each hydraulic reservoir... Audible and visual alarm shall be given on the navigation bridge and in the machinery space. Unable to verify proper operation of low level hydraulic alarm for either steering pump. Additionally PSCO were unable to verify operation of the steering gear's low voltage alarm. 74SOLAS(04) II-1/29.12.2 60AC
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 August 2019
Resolution: Received a class report stating the malfunction of steering alarms was traced to a loose terminal in the power supply strip of the steering gear alarm panel in the wheel house. Both were tested and are working properly.
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. Class A fire door for the engine room, purifier room, and class a fire door for the CO2 Room were unable to close properly. 74SOLAS(04) II-2/9.4.2.1 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2019
Resolution: PSCOs witnessed proper operation of required fire doors.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 August 2019Resolved
Fixed Fire Detection system installations shall be suitable for the nature of the space. Smoke detector above lube oil purifier was held in place with tape, but was operational during test. Improper installation of detector was not reported to company 74SOLAS(04) II-2/7.1.1 16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 August 2019
Resolution: Received class report stating that the smoke detector had been repaired, tested and is working correctly.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 16 January 2017Resolved
001 - 0725- SHIP SHALL KEEP FIRE FIGHTING APPLIANCES READILY AVALIABLE FOR IMMEDIATE USE. VALVE SUPPLYING WATER TO HYPER MIST SYSTEM WAS PARTIALLY CLOSED. -SOLAS 09 CONS II-2/14.2.1 - 10C
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 January 2017
Resolved 16 January 2017