MAURY USCG vessel records
← All vessels

MSC SUAPE VII

MSC SUAPE VII is a 2001 freight ship. The Coast Guard has recorded 39 inspections since 2016, most recently in April 2026, along with 29 deficiencies and 7 operational controls.

Records from 2016 to 2026. Most recent: inspection, 11 April 2026.

Built
2001
Last inspected
11 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 April 2026
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9222285
1100255
Flag
LIBERIA
Maury page id
psix-1100255

Documentation record

Tonnage as PSIX records it73172 - Convention (Subpart B), Gross Ton
104555 - Displacement, Metric Ton
77941 - Dead Weight, Metric Ton
40905 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 39

11 April 2026 PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8345388
15 December 2025 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8283461
10 December 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8278487
10 December 2025 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8281499
24 September 2025 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8239017
17 September 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8235886
15 September 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8234838
7 May 2024 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7907441
23 April 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7900054
5 February 2024 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7860491
29 January 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7857648
17 November 2023 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7826642
15 November 2023 Deficiency Check · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7825091
9 November 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7820681
27 April 2023 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7676583
22 April 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7673351
19 April 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7671763
10 February 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7639407
6 December 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7604905
14 October 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7577453
25 September 2022 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7560398
8 April 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7427121
8 January 2022 PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7377199
6 January 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7376416
1 January 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7374413
23 April 2020 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6942822
21 April 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6941662
17 April 2020 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6940560
9 January 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6885886
23 September 2019 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6817255
18 September 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6814517
11 September 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6809090
1 September 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6810005
1 November 2018 ISPS III Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6572411
1 November 2018 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6577223
4 September 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6531387
26 August 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6523049
15 May 2016 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5878759
17 March 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5834952

Deficiency record · 29

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 December 2025 Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. While conducting mooring operations, the vessel lost means of propulsion.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 11 December 2025
Resolved 11 December 2025
Resolution: Class report received and reviewed. Vessel repaired malfunctioning part and conducted propulsion tests.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2025 Resolved
All electrical apparatus shall be constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed dead-end wires not energized throughout the engine room. Also observed electrical tape on live wires that were not properly housed. 74SOLAS(04) II-1/45.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2025
Resolved 29 October 2025
Resolution: BV Class attestation report with photos received and uploaded by Sector NY.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 24 September 2025 Resolved
The arrangements for the storage, distribution and utilization of other flammable oils employed under pressure in power transmission systems, control and activating systems and heating systems shall be such as to ensure the saftey of the ship and persons on board. PSCO observed oil soaked lagging on the main diesel engine. 74SOLAS(01) II-2/15.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 September 2025
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 September 2025 Resolved
Means shall be provided to contorl leaks of flammable liquids. PSCO observed accumulation of oil by pressure valves. 74SOLAS(04) II-2 Reg 4.1.1.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 September 2025
Resolved 17 September 2025
Resolution: Crew cleaned the area.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 September 2025 Resolved
The following fire protection systems shall br kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire resisting divisions, and protection of openings and penetrations in these divisions. PSCO observed unapproved penetration was made through A/C unit ducting in engin control room. 74SOLAS(04) II-2 Reg 14.2.1.1.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2025
Resolution: Class Survey report
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 September 2025 Resolved
The machinery, boilers, and other pressure vessels associated piping systems and fittings shall be of a design and construction adequate for the service which they are intended and shall be so installed and protected as to reduce to a minimum any danger to the persons on board, due regard being paid to moving part, hot surfaces, and other hazards. PSCO observed excessive leaking on steering gear pump no. 2 during test. 74SOLAS(04)II-2 Reg 26.1.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 September 2025
Resolution: Class Survey report witness tighening of bolts on the steering pump.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 September 2025 Resolved
The machinery, boilers, and other pressure vessels associated piping systems and fittings shall be of a design and construction adequate for the service which they are intended and shall be so installed and protected as to reduce to a minimum any danger to the persons on board, due regard being paid to moving part, hot surfaces, and other hazards. PSCO observed boiler cascade tank over flowing.74SOLAS(04)II-2 Reg 26.1.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 September 2025
Resolved 17 September 2025
Resolution: Engineering Department rectified issue and cleaned.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 February 2024 Resolved
The activation of any detector or manually operated call point shall initiate a visual and audible fire signal at the control panel and indicating units. PSCO observed three inoperable signal columns at three different locations throughout machinery space; forward engine room, STBD side generator room, and purifier room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 April 2024
Resolution: Received RO report that spare parts has been installed and def ractified.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 17 November 2023 Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the administration in accordance with the provisions of regulation XI/1, or with applicable national standards of the administration which provide an equivalent level of safety. PSC officers observed significant wastage and corrosion on elevated walkways and lashing platforms resulting in a safety hazard. Conditions observed to include but not limited to the elevated walkways and lashing platforms forward of bays 01, 04, 09, 38, and 49. Code 40ab
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 January 2024
Resolution: Class survey on 29JAN2024 with report received same day attesting to repairs.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 November 2023 Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevants rules and regulations established by the company. The technical and operational nature of the deficiencies noted on deficiencies 02, 03, and 04 provide objective evidence of a serious failure of the implementation of the ISM Code. An external audit report satisfactory to the OCMI must be submitted prior to clearance of this deficiency. 74 SOLAS (2020) IX/13.1 ISM Part A 10.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 15 November 2023
Resolved 17 November 2023
Resolution: Flag conducted external audit and provided report clearing the def.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 November 2023 Resolved
Fire-extinguishing appliances shall be kept in good order and be ready for immediate use at all times. PSCO observed securing pins installed on three out of 383 vessel's pressure release valves on the fixed CO2 system. The vessel's manual for this system states "The securing pins and the steel wire must always be removed when a system is put into operation." and requires 383 bottles to fight a fire in the vessel E/R. The bottles with the securing pins installed were #8, #50, and #113. With these securing pins installed the required number of CO2 bottles would not have discharged in the case of an emergency. Posing a significant threat to the safety of the vessel and its crew. 74 SOLAS (2001) II-2/21
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 15 November 2023
Resolved 15 November 2023
Resolution: Ship's Crew removed the PINS and verified that no other pressure operated valves of the CO2 System are secured with Safety Pins, see attached class report
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 15 November 2023 Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society which is recognized by the administration in accordance with the provisions of regulastion XI/1, or with applicable national standards of the administration which provide equivalent level of safety. PSCO observed excessive corrosion on the elevated walkways around each container bay and cracks to the hand rails on the starboard stairs leading to the aft mooring deck. 74 SOLAS (2001) II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2023
Resolved 17 November 2023
Resolution: Received mitigation statement from the master in conjunction with class report clearing deficiencies.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 November 2023 Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed excessive F/O leak on cylinder # 14 on the M/E, throughout the purifier room, and auxiliary throughout generator. 74 SOLAS (2001) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2023
Resolved 17 November 2023
Resolution: Received mitigation statement from the master in conjunction with class report clearing deficiencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2023 Resolved
The machinery associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to person on board. PSCO observed excessive cooling water leak from the high temp M/E jacket water cooler. 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2023
Resolution: received class report attesting to proper repairs and operation.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 9 November 2023 Resolved
Every steam pipe and every fitting connected there to through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses. PSCO observed steam leak on cut off valve and pressure regulating valve for control steam to LO purifier. 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2023
Resolution: received class report attesting to proper repairs and operation.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 November 2023 Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons onboard. PSCO observed excessive F/O leak on #2 HFO purifier feeder pump. 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2023
Resolution: received class report attesting to proper repairs and operation.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 November 2023 Resolved
In a ship in which oil fuiel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons onboard. PSCO observed excessive F/O leak form a gasket on the supply line to F/O bunkering pump. 40ac SOLAS II-2/15
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 January 2024
Resolution: Verified by Class surveyor on 18DEC2023 with Class survey and report attesting to repairs received on 29JAN2024.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2023 Resolved
The machinery associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce a minimum any danger to persons on board. PSCO observed excessive salt water leak from main cooling sea water pump. 40ac 74 SOLAS (04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 January 2024
Resolution: Verified by Class surveyor on 18DEC2023 with Class survey and report attesting to repair received on 29JAN2024.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 9 November 2023 Resolved
After any survey of the ship under regulation 10 has been completed, no change shall be made in the structural arrangement covered by the survey, without the sanction of the amdministration. PSCO observed two modified wooden dooors welded to the bulkhead on the 2nd deck. 40ac 74SOLAS (20) I/11 (b)
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 January 2024
Resolution: Verified by Class survey with Class report dated 16NOV2023 attesting to rectification.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 November 2023 Resolved
The machinery associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce a minimum any danger to persons on board. PSCO observed excessive fresh water leak from freshwater line in passageway leading to the paint locker. 50ac SOLAS II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 January 2024
Resolution: Verified by Class surveyor on 18DEC2023 with Class survey and report attesting to repair received on 29JAN2024.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 8 April 2022 Resolved
33 cfr 164.35(d)- Vessel is to provide tech report and repairs on gyro prior to departure.
Action required: 10 - Deficiency Rectified
Due 8 April 2022
Resolved 12 April 2022
Resolution: vsl submitted class report certifying repairs for gyro.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 January 2022 Resolved
The examiner observed serveral CO2 cylinders on the fixed exstinguishing system had a considerable amount of rust despite recent service on 08MAY21. Class and Flag were made aware of the USCG observation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 January 2022
Resolved 19 January 2022
Resolution: Class was on vessel during exam and stated that they were satified with the condition of the bottle, but they would bring the issue up to flag and USCG NY PSC will be included in the email/ conversation.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 September 2019 Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met: Fire protection systems and firefighting systems and appliances shall be maintained ready for use. Activated emergency fie pump and tested fire hose on starboard bridge wing and tested fire hose which discharged oil mixed with firefighting water. Examined fire station’s and found additional 02 to be contaminated with oil on deck and 02 contaminated fire stations in the engine room. Also found hole in main fire pipe leaking water into a 55-gallon drum which filled completely in one hour. Lastly, found 06 fire extinguishers overdue for servicing. Vessel needs to create proposal plan for cleaning entire fire main system, a plan for safely disposing of oil from the fire main system and needs to have adequate firefighting measures in place during the cleaning process.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Due 19 September 2019
Resolved 23 September 2019
Resolution: Reviewed class report from BV stating that the fire main was cleaned by NRC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 September 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. While conducting engine room exam, found 18 inches of oily water mixture in starboard side aft bilge well underneath shaft seal and in starboard side barge well underneath propeller shaft. See first deficiency for oil found in fire main system.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 19 September 2019
Resolved 23 September 2019
Resolution: Received class report from BV stating that the condictioned observed by the PSCO was considered normal operational condition. Port and STBD bilge wells are 4.5 feet deep. The bilge wells were cleaned by the crew as a precautionary measure.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 11 September 2019 Resolved
The safety management system should include procedures ensuring that non-conformities, accidents and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety and pollution prevention. Master explained that vessel sucked up oil from a sheen in the water while sailing through the Persian Gulf two months ago via the ship’s emergency fire pump. One month later, BOSN reported that the pool “reeked” of a fuel oil smell while attempting to fill the pool. Captain failed to report either instance to the company and was not surprised when fire hose on bridge wing discharged oily water mixture. In addition, galley fixed CO2 extinguisher had not been checked since March 2019. Battery room extinguisher has not been checked since June 2019. Engine room had 04 extinguishers overdue for annual servicing but are marked “ok “ or “good” on monthly servicing tag. Recommend full ISM audit.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 19 September 2019
Resolved 24 September 2019
Resolution: BV report states: "surveyor was unable to verify and objectively report on the PSCOs finding as only subjective verbal statement was provided to and reported by the [name withheld] fire insp were proven to be signed off in the vessel's PMS. See documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 11 September 2019 Resolved
THE NAME AND PORT OF REGISTRY OF THE SHIP TO WHICH THE LIFEBOAT BELONGS SHALL BE MARKED ON EACH SIDE OF THE LIFEBOATS BOW IN BLOCK CAPITAL LETTERS OF THE ROMAN ALPHABET. WHILE CONDUCTING THE ABANDON SHIP DRILL, IT WAS OBSERVED THAT NO NAME OF SHIP OR PORT WAS PRESENT ON EITHER OF THE LIFEBOATS.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2019
Resolution: BV surveyor inspected port and stbd lifeboat and confirmed ship's name and port of registry remained originally marked on each lifeboat's bow. See documents for class report.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 11 September 2019 Resolved
EACH OPERATION DESCRIBED IN PARAGRAPH 2 OF THIS REGULATION SHALL BE FULLY RECORDED WITHOUT DELAY IN THE OIL RECORD BOOK PART 1, SO THAT ALL ENTRIES IN THE BOOK APPROPRIATE TO THE OPERATION ARE COMPLETED. WHILE REVIEWING OIL RECORD BOOK PART 1, IT WAS OBSERVED THAT THE ENTRY MADE ON 13JULY2019 EXCEEDED OIL FILTERING EQUIPMENT MAXIMUM RATE OF FILTRATION BY 9M3 OVER A PERIOD OF 6 HOURS.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2019
Resolution: BV surveyor reviewed ORB enrty dd 7/13/19 and noted the op started at 08:00 and with close up examination of C/E handwriting, ended at 17:00. This run time is within paramaters of OWS capicity. See documents for class report.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 11 September 2019 Resolved
After any survey of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery equipment and other items covered by the survey , without the sanction of the administration. Vessel made repairs to the top of port side fuel tank in cargo hold #3 and dod not get classification society approval. USCG requires class report before sailing to next port.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2019
Resolved 23 September 2019
Resolution: BV surveyor reviewed documentation proving acceptable repair to tank. Could not conduct NDT due to containers in hold #3. see BV report in documents.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 September 2019 Resolved
Where it is intended to carry flammable or toxic liquids in enclosed cargo spaces, the bilge pumping system shall be deisgned to ensure against inadvertant pumping of such liquids through machinery space piping or pumps. Fuel oil was observed in the fire main while testing fire hoses on 11SEPT2019. Verify crossover connectionvalve is not leaking when in closed position, preventing fuel oil from inadvertantly entering fire main.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2019
Resolved 23 September 2019
Resolution: E/R cargo hold bilge suction valve port (BG55) dismantaled, tested and found leaking under pressure. Valve overhauled and tested satisfactorily.

Ownership record