Records from 2016 to 2026. Most recent: inspection, 11 August 2026.
Inspection history · 18
11 August 2026
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8461592
17 November 2025
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8269702
22 August 2025
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8215671
18 August 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8210592
21 May 2025
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8141064
12 March 2025
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8092444
10 September 2024
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7999982
7 February 2024
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7862022
19 July 2022
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7510947
4 January 2022
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7375390
18 May 2021
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7200111
3 March 2021
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7149580
9 December 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7108820
9 December 2020
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7109139
27 September 2020
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7066030
25 September 2019
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6820411
8 August 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6765948
17 November 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6043440
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 18 August 2025
Resolved
A self-contained emergency source of electrical power shall be provided. PSCO was informed by Chief Engineer that Emergency Generator experienced a malfunction rendering it in-operable.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2025
Resolution: Vessel provided a satisfactory class survey report attesting to satisfactory installation and acceptance of a containerized generator set (CGS) as a temporary measure until emergency generator repair work is completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 8 August 2019
Resolved
Where coamings are providedon cargo hatches, they shall be of substantial construction. The compression bars for cargo holds #2,4, and 5 are wasted and folded in many places.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 September 2019
Resolution: Received, reviewed, and accpeted class report. See Narrative and documents for details.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 November 2016
Resolved
74 SOLAS (2014 CONS.) CH. II-2/14.2.1.1.1; 10C; THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD WORKING ORDER AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS: STRUCTURAL FIRE PROTECTION, INCLUDING FIRE RESISTING DIVISIONS. THE FOLLOWING CLASS "A" CLASS SELF-CLOSING FIRE DOORS DID NOT PROPERLY SHUT: #409, #304, & #307.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 17 November 2016
Resolution: ALL SPECIFIED DOORS FIXED.