MAURY USCG vessel records Sign in
← All vessels

SEAPACE

SEAPACE is a freight ship. The Coast Guard has recorded 3 inspections in 2014, along with 3 deficiencies and 1 operational control.

Records in 2014. Most recent: inspection, 25 August 2014.

Built
Not recorded
Last inspected
25 August 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9486025 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA2223
1100440
Flag
MALTA
—
Maury page id
psix-1100440

Inspections, by type

…with no type recorded1
Years with a record 1 calendar year (2014)
The 3 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it19270 - Simplified, Net Ton
33036 - Convention (Subpart B), Gross Ton
33036 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 3

25 August 2014 Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4965140
9 May 2014 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4849897
9 May 2014 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4851765

Deficiency record · 3

Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 May 2014 Resolved
Maintenance, testing and inspection shall be carried out based on guidelines developed by the organization. 3 portable fire extinguishers: 02 in the galley and 01 in the engine room did not have a monthly inspection in April and March and April respectively. SOLAS 75/II-2 Part E Reg. 14.2.1
Due 23 May 2014
Resolved 28 August 2014
Resolution: Received class report clearing deficiency.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 May 2014 Resolved
Guard rails or bulwarks shall be fitted around all exposed decks. Fixed stanchions shall be fitted about 1.5 M apart. 01 stanchion located at or about frame 55 starboard side was found to be wasted and disconnected from the main deck. ICLL 1966 05 edition Annex I Reg 25.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 August 2014
Resolution: Received class report stating that proper repairs have been made.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 May 2014 Resolved
After any survey of the ship under MARPOL Annex I regulation 6.1 has been conducted, no changes shall be made to anything covered by the survey without sanction of the administration. It was discovered by the PSCO that the tamper seal for the OCM was broke. Furthermore, wiring in the electrical control cabinet does not match the circuit diagram drawing. MAROL con 2011 Annex I/reg 4.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 August 2014
Resolution: Received technicians report and class reporting stating that OWS is now working correctly.

Ownership record