MAURY USCG vessel records Sign in
← All vessels

STINNES MISTRAL

STINNES MISTRAL is a 2008 public freight. The Coast Guard has recorded 28 inspections since 2014, most recently in August 2026, along with 8 deficiencies and 5 operational controls.

Records from 2014 to 2026. Most recent: inspection, 19 August 2026.

Built
2008
Last inspected
19 August 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9452218 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1100497
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-1100497

Inspections, by type

…with no type recorded6
Years with a record 9 calendar years (2014–2026)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it9530 - Convention (Subpart B), Gross Ton
11547 - Dead Weight, Metric Ton
16712 - Displacement, Metric Ton
4398 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

19 August 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8468024
22 June 2026 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8410638
6 April 2026 In-Service Inspection · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8340609
3 April 2026 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8341228
3 November 2025 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8261348
14 September 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8234003
7 September 2025 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8228926
3 July 2025 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8168529
14 May 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8135779
6 May 2025 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8116155
6 May 2025 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8130946
25 April 2025 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8113397
21 April 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8116189
6 March 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8089187
13 February 2024 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7861665
8 July 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7485004
1 August 2018 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6498304
26 July 2018 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6491419
31 March 2018 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6382385
29 March 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6381501
6 March 2018 Ballast Water Examination · NPV Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6360783
28 February 2017 COE-Offshore · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6095335
25 February 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6094424
12 September 2016 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5999005
18 October 2015 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5745368
16 October 2015 ISPS II Exam · Deficiency Check · PII Safety Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5744664
6 September 2015 ISPS II Exam · COE-Dockside
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5228497
7 March 2014 COE-Dockside
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4803960

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 November 2025 Resolved
To suppress and swiftly extinguish fire in the space of origin, fire extinguishing appliances shall be readily available. PSCO observed crew was unable to quickly access the CO2 room due to the provided key not working on the lock. 74 SOLAS (04) II-2 / 10.1.2 Action code: 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 3 November 2025
Resolved 3 November 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 July 2025 Resolved
The guard rail courses shall be not more than 380mm (15 inches) apart. PSCO observed guard rails bent beyond 15 inches apart. ICLL 66 25.3
Action required: 10 - Deficiency Rectified
Due 3 July 2025
Resolved 3 July 2025
Resolution: Vessel able to correct/bend back while PSCO was onboard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 May 2025 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. PSCO observed tape over fire detectors in bosn. stores. 74SOLAS(09)II-2/14.2.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 May 2025
Resolved 6 May 2025
Resolution: PSCO observed tape removed from the fire detectors.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 25 April 2025 Resolved
After any survey of ship under paragraph 1 of this regulation has been completed, no change shall be made in the structure, equipment, systems, fittings, arrangements, or material covered by the survey, without the sanction of the administration. PSCO observed modified valve installation not pictured on E/R oily water separating system diagram. Request clarification from certificate issuing authority on continued acceptance. 22 MARPOL Annex I / 6.4.2 50AC
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2025
Resolved 14 May 2025
Resolution: Vessel removed valve installation. See class repot uploaded to documents.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 25 April 2025 Resolved
Oil residue (sludge) may be disposed of directly from oil residue (sludge) tank(s) to reception facilities through the standard discharge connection referred to in regulation 13, or to any other approved means of disposal of oil residue(sludge), such as an incinerator, auxiliary boiler suitable for burning oil residue (sludge) or other acceptable means which shall be annotated in item 3.2 of the supplement to IOPP certificate form A or B. PSCO observed entry in ORB indicating sludge from F.O sludge tank was sent to F.O Settling Tank, an operation not authorized as an acceptable means of disposal of sludge on the IOPP certificate form A. Request clarification from certificate issuing authority for continued acceptance. 22 MARPOL Annex I/12.2 50AC
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2025
Resolved 15 May 2025
Resolution: Operation will be logged as an (I) entry in the ORB. See class report in documents.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 February 2017 Resolved
1730-OWS-PSCO witnessed operational testing of the system, no sample flowing to the OCM and system not operating as designed. Ships crew needed to disassemble sample lines/fittings in order for sample to move through the sample line. Crew was unable to initially produce effluent below 15 ppm. Effluent visibly dirty and filters had last been cleaned on 29APR14. MARPOL ANNEX 1(2011 CONS)14.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 28 February 2017
Resolution: SHIPS CREW WAS ABLE TO PROVE PROPER OPERATION OF THE OILY WATER SEPERATOR, WITH A SAMPLE BEING SUPPLIED TO THE OIL CONTENT METER, AND AN EFFLUENT BELOW 15PPM, AS WELL AS PROPER OPERATION OF THE 3WAY VALVE AND ALARMS. DEFICIENCY WAS RECTIFIED ON THE SPOT.
Construction/Loadline › Hull › Side Shell
Issued 16 October 2015 Resolved
The administration shall satisfy itself that the strength of the vessel is adequate for the draught corresponding to the freeboard. Frames 19-29 are buckled and inset 2 feet on the starboard quarter. Provide class report attesting to strength of vessel.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 17 October 2015
Resolved 18 October 2015
Resolution: Issued COTP order to allow transit to Montrea, CA for temp repairs.
Construction/Loadline › Hull › Side Shell
Issued 16 October 2015 Resolved
The administration shall satisfy itself that the strength of the vessel is adequate for the draught corresponding to the freeboard. Frames 19-29 are buckled and inset 2 feet on the starboard quarter.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 October 2015
Resolution: Received class report attesting to temporary repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.