MAURY USCG vessel records
← All vessels

COSMOS

COSMOS is a 2010 freight ship. The Coast Guard has recorded 7 inspections since 2017, most recently in November 2023, along with 2 deficiencies.

Records from 2017 to 2023. Most recent: inspection, 1 November 2023.

Built
2010
Last inspected
1 November 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 November 2023
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2017–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9574171
1100528
Flag
MARSHALL ISLANDS
Maury page id
psix-1100528

Documentation record

Tonnage as PSIX records it17019 - Convention (Subpart B), Gross Ton
28389 - Dead Weight, Metric Ton
34753 - Displacement, Metric Ton
10108 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

7 inspections, each with its date, unit and type; 2 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

1 November 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7815948
4 April 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7421557
18 May 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7200358
12 May 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7195542
15 December 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7112342
30 July 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6488129
6 May 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6140139

Deficiency record · 2

14 - Pollution Prevention › 145 - MARPOL Annex V › Other (MARPOL Annex V)
Issued 4 April 2022 Resolved
PSCO observed zero entries in the garbage record book Part II. [name withheld] stated cargo residue wash was discharged through the bilge. Request corrective action plan to the satisfaction of the administration. (MARPOL V/10.3.2) (16bc)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 20 April 2022
Resolution: Received, reviewed and accepted proper documentation from master stating the deficiency was rectified. Master provided Garbage Record Book part II entries, a signed non-conformity report, and approval from administration for the Corrective Action Plan.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 July 2018 Resolved
The function of fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the Administration by means of equipment producing hot air at the appropriate temperature, or smoke or aerosol particles having the appropriate range of density or particle size, or other phenomena associated with incipient fires to which the detector is designed to respond. The vessel's only means to test the fire detector is a portable gas powered torch burner.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2018
Resolved 2 August 2018
Resolution: Witnessed satisfactory test of smoke detectors with approved testing device.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.