ALTUM SIDUS is a 2010 tank ship. The Coast Guard has recorded 13 inspections since 2017, most recently in August 2026, along with 4 deficiencies and 4 operational controls.
Records from 2017 to 2026. Most recent: operational control imposed, 18 August 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it29124 - Convention (Subpart B), Gross Ton 11608 - Convention (Subpart B), Net Ton 56610 - Displacement, Metric Ton 45612 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 13
18 August 2026Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8467413
17 May 2024PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7913969
13 April 2023COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7661619
27 September 2022Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7566955
4 August 2022Ballast Water Examination · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7524615
13 January 2022Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7379727
13 January 2022Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7379757
12 January 2022COC-CHEM & TVE Renew
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7376990
5 January 2021Deficiency Check · COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7118165
12 October 2019COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6833236
7 September 2018Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6534897
19 August 2018Ballast Water Examination · PII Safety Exam · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6516222
23 June 2017COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6173562
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the authorized ballast water management methods listed in 33 CFR 151.2025(a). Vessel’s ballast water management system is inoperable. Vessel has been granted an extraordinary circumstance to employ the ballast water management method listed in 33 CFR 151.2025(a)(3) to conduct cargo operations while in the Sector New Orleans COTP Zone. In accordance with 33 CFR 151.2040(b)(3), the vessel must discharge only that amount of ballast water operationally necessary to ensure the safety and stability of the vessel for cargo operations.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 September 2022
Resolution: Provided class report & new certificate proving full functionality.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 12 January 2022Resolved
ALL SHIPS OF 3,000 GT AND UPWARD SHALL, IN ADDITION TO MEETING THE REQUIREMENTS OF PARAGRAPH 2.5 HAVE A3 GHZ RADAR OR, WHERE CONSIDERED APPROPRIATE BY THE ADMINISTRATION, A SECOND 9 GHZ RADAR. THE VESSEL'S S-BAND RADAR IS NON-OPERATIONAL.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2022
Resolved 14 January 2022
Resolution: Vessel repaired and received class report
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 5 January 2021Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFIRM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. STEAM LINE FOR #3 PORT CARGO TANK FOUND PUNCTURED. PUNCTURE WAS LOCATED NEAR THE STEAM LINE SUPPLY ISOLATION VALVE, CENTERLINE OF THE VESSEL.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 28 January 2021
Resolution: STEAM LINE REPLACED.
ALL THE STEERING GEAR COMPONENTS SHALL BE OF SOUND AND RELIABLE CONSTRUCTION TO THE SATISFACTION OF THE ADMINISTRATION. PSCO OBSERVED A LUBE OIL LEAK FROM THE RAM SEAL ON #2 STEERING GEAR SIDE. CREW WAS ABLE TO TIGHTEN BOLTS FOR RAM SEAL TO STOP LEAK. PSCO TESTED STEERING GEA SATISFACTORALY WITH NO LEAKS.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 January 2021
Resolution: CREW WAS ABLE TO TIGHTEN BOLTS FOR RAM SEAL TO STOP LEAK. PSCO TESTED STEEERING GEAR SATISFACTORALY WITH NO LEAKS
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.