MAURY USCG vessel records
← All vessels

ANGLO JESSICA

ANGLO JESSICA is a 2010 freight ship. The Coast Guard has recorded 20 inspections since 2016, most recently in February 2024, along with 9 deficiencies and 2 operational controls.

Records from 2016 to 2024. Most recent: operational control imposed, 27 February 2024.

Built
2010
Last inspected
27 February 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9490480
1100670
Flag
UNITED KINGDOM
Maury page id
psix-1100670

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 7 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it64100 - Simplified, Gross Ton
64100 - Convention (Subpart B), Gross Ton
37823 - Simplified, Net Ton
37823 - Convention (Subpart B), Net Ton
114671 - Dead Weight, Metric Ton
134908 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 20

27 February 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7871098
22 February 2024 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7868942
3 January 2024 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7844805
28 December 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7875713
17 December 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7610377
28 November 2022 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7600668
25 September 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7320348
16 September 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7313898
31 August 2021 Administrative Inspection · In-Service Inspection · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7277069
7 June 2021 PSC B · Deficiency Check · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7219025
7 June 2021 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7219827
2 June 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7213224
2 June 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7213321
6 January 2021 PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7120268
6 January 2021 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7120517
21 December 2018 Ballast Water Examination · NPV Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6599963
3 December 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6581530
3 May 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6132180
4 November 2016 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6035544
23 March 2016 ISPS II Exam · MARPOL Annex VI Survey · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5834995

Deficiency record · 9

03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 January 2024 Resolved
For all ships, the means of embarkation and disembarkation shall be inspected and maintained in suitable condition. PSCO observed starboard accomodation ladder damaged and unable to be deployed. 74SOLAS(20) 3-9/3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 January 2024
Resolved 22 February 2024
Resolution: PSC NOLA received a class report from ABS satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 7 September 2021 Resolved
Personal Equipment shall consist of protective clothing of material to protect the skin from the heat radiating from the fire and from burns and scalding by steam. During the fire drill, PSCO noted minor damage to the fire trousers. 74 SOLAS (04) II-2/10.10.1 - FSS 3.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 30 September 2021
Resolved 8 September 2021
Resolution: Sent photos of new fireman;s outfit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 August 2021 Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. Vessel was unable to control main engine from navigation bridge or engine control room at the pilot's request. Crew determined the electronic card of the DGU digital governor unit was defective, which allowed for local control of main engine only. 74 SOLAS (2009 Cons.) II-1/31.1 - 60 a/c
Action required: 60 - Rectify deficiencies prior to movement
Due 31 August 2021
Resolved 4 September 2021
Resolution: Received satisfactory class report clearing the def.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2021 Resolved
FIREFIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED DEGREDATION OF CO2 ACTIVIATION CONTROL BOX ON EXTERIOR BULKHEAD OF EMERGENCY GENERATOR SPACE. 74 SOLAS (04) II-2/14.2.1.2
Action required: 10 - Deficiency Rectified
Due 11 June 2021
Resolved 11 June 2021
Resolution: VESSEL PUT NEW GASKET MATERIAL IN PLACE AND REMEDIED THE DOGGING MECHANISM.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 June 2021 Resolved
HOSES SPECIFIED IN THIS CHAPTER AS "FIRE HOSES" SHALL, TOGETHER WITH ANY NECESSARY FITTINGS AND TOOLS, BE KEPT READY FOR USE IN CONSPICUOUS POSITIONS NEAR THE WATER SERVICE HYDRANTS OR CONNECTIONS. PSCO DISCOVERED 01 FIRE HOSE ON PORT SIDE OF CARGO HOLD DEGRADED WITH FAILING O-RINGS. 74 SOLAS (04) II-2/10.2.3.1.1
Action required: 10 - Deficiency Rectified
Due 11 June 2021
Resolved 11 June 2021
Resolution: VESSEL REPLACED HOSE WITH NEW HOSE AND DESTROYED OLD HOSE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 June 2021 Resolved
MAIN AND AUXILIARY MACHINERY ESSENTIAL FOR THE PROPULSION AND SAFETY OF THE SHIP SHALL BE PROVIDED WITH EFFECTIVE MEANS FOR ITS OPERATION AND CONTROL. VESSEL PILOT REPORTED A LOSS OF PROPULSION DURING INBOUND TRANSIT CAUSING IT TO GROUND. VESSEL'S MAIN ENGINE SHUT DOWN DUE TO LOSS OF COOLING JACKET WATER FOR MAIN ENGINE. REQUEST CLASS ATTENDANCE AND SURVEY REPORT ATTESTING TO PROPER OPERATIONS OF THE VESSEL'S MAIN ENGINE AND WATER INGRESS CONDITION. THE VESSEL SHALL REMAIN AT CORPUS CHRISTI ANCHORAGE. 74 SOLAS(04)II-1/31.1 16 a/c
Action required: 60 - Rectify deficiencies prior to movement
Due 7 June 2021
Resolved 8 June 2021
Resolution: Cleared the deficiency from class report allowing the vessel to enter port for PSC-B Exam on 11JUN21
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 January 2021 Resolved
07126- Means shall be provided to control leaks of flammable liquids. The No. 2 Gererator had active leaks at the no. 2,3,4 and 5 cylinder fuel pumps and the No. 3 generator had active leaks at the No. 2 and 4 cylinder fuel pumps. Also leaks were found at the sight glass on the piping leading from the HFO tank. 74 SOLAS (04) II-2/4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2021
Resolution: Received class surveyor report
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 6 January 2021 Resolved
15106- The company should establish procedures to ensure that new personnel related to safety and protection of the environment are given proper familiarization with their duties, with instructions provided prior to sailing. PSCO observed the vessel's sewage tank overflowing after reviewing daily sounding records, it was determined that the 4th extinguisher was not taking correct soundings of the tank. 4th engineer recorded in the last sounding that the tank was approximately 18 m^3, about 25% of the capacity. PSCO believes the 4th Engineer was not given proper familiarization with his duties. 74 SOLAS(14) IX/3.1 ISM CODE 6.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2021
Resolution: Received class surveyor report and crew training documentation
Fire Fighting › Fire Hoses › Condition
Issued 23 March 2016 Resolved
0720: Firefighting appliances and systems shall be maintained ready for use. PSCO Observed that the vessels crew was unable to successfully charged the ships fire hoses with the emergency fire pump. SOLAS 14 II-2/14.1 Action Taken: 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2016
Resolved 24 March 2016
Resolution: Recieved class report stating that emergency fire pump was satisfactorily repaired and tested.

Ownership record