← All vessels
ANGLO JESSICA
ANGLO JESSICA is a 2010 freight ship. The Coast Guard has recorded 21 inspections since 2014, most recently in February 2024, along with 9 deficiencies and 2 operational controls.
Records from 2014 to 2024. Most recent: operational control imposed, 27 February 2024.
- Built
- 2010
- Last inspected
- 27 February 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9490480 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
MFTU8
1100670
Flag
UNITED KINGDOM
—
Maury page id
psix-1100670
Inspections, by type
…with no type recorded2
Years with a record
8 calendar years (2014–2024)
The 21 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it64100 - Simplified, Gross Ton
64100 - Convention (Subpart B), Gross Ton
37823 - Simplified, Net Ton
37823 - Convention (Subpart B), Net Ton
114671 - Dead Weight, Metric Ton
134908 - Displacement, Metric Ton
64100 - Convention (Subpart B), Gross Ton
37823 - Simplified, Net Ton
37823 - Convention (Subpart B), Net Ton
114671 - Dead Weight, Metric Ton
134908 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 21
27 February 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7871098
22 February 2024
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7868942
3 January 2024
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7844805
28 December 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7875713
17 December 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7610377
28 November 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7600668
25 September 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7320348
16 September 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7313898
31 August 2021
Administrative Inspection · In-Service Inspection · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7277069
7 June 2021
PSC B · Deficiency Check · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7219025
7 June 2021
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7219827
2 June 2021
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7213224
2 June 2021
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7213321
6 January 2021
PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7120268
6 January 2021
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7120517
21 December 2018
Ballast Water Examination · NPV Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6599963
3 December 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6581530
3 May 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6132180
4 November 2016
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6035544
23 March 2016
ISPS II Exam · MARPOL Annex VI Survey · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5834995
3 March 2014
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4808945
Deficiency record · 9
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 January 2024
Resolved
For all ships, the means of embarkation and disembarkation shall be inspected and maintained in suitable condition. PSCO observed starboard accomodation ladder damaged and unable to be deployed. 74SOLAS(20) 3-9/3
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 7 September 2021
Resolved
Personal Equipment shall consist of protective clothing of material to protect the skin from the heat radiating from the fire and from burns and scalding by steam. During the fire drill, PSCO noted minor damage to the fire trousers.
74 SOLAS (04) II-2/10.10.1 - FSS 3.2.1.1.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 August 2021
Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. Vessel was unable to control main engine from navigation bridge or engine control room at the pilot's request. Crew determined the electronic card of the DGU digital governor unit was defective, which allowed for local control of main engine only.
74 SOLAS (2009 Cons.) II-1/31.1 - 60 a/c
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2021
Resolved
FIREFIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED DEGREDATION OF CO2 ACTIVIATION CONTROL BOX ON EXTERIOR BULKHEAD OF EMERGENCY GENERATOR SPACE.
74 SOLAS (04) II-2/14.2.1.2
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 June 2021
Resolved
HOSES SPECIFIED IN THIS CHAPTER AS "FIRE HOSES" SHALL, TOGETHER WITH ANY NECESSARY FITTINGS AND TOOLS, BE KEPT READY FOR USE IN CONSPICUOUS POSITIONS NEAR THE WATER SERVICE HYDRANTS OR CONNECTIONS. PSCO DISCOVERED 01 FIRE HOSE ON PORT SIDE OF CARGO HOLD DEGRADED WITH FAILING O-RINGS.
74 SOLAS (04) II-2/10.2.3.1.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 June 2021
Resolved
MAIN AND AUXILIARY MACHINERY ESSENTIAL FOR THE PROPULSION AND SAFETY OF THE SHIP SHALL BE PROVIDED WITH EFFECTIVE MEANS FOR ITS OPERATION AND CONTROL. VESSEL PILOT REPORTED A LOSS OF PROPULSION DURING INBOUND TRANSIT CAUSING IT TO GROUND. VESSEL'S MAIN ENGINE SHUT DOWN DUE TO LOSS OF COOLING JACKET WATER FOR MAIN ENGINE. REQUEST CLASS ATTENDANCE AND SURVEY REPORT ATTESTING TO PROPER OPERATIONS OF THE VESSEL'S MAIN ENGINE AND WATER INGRESS CONDITION. THE VESSEL SHALL REMAIN AT CORPUS CHRISTI ANCHORAGE.
74 SOLAS(04)II-1/31.1
16 a/c
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 January 2021
Resolved
07126- Means shall be provided to control leaks of flammable liquids. The No. 2 Gererator had active leaks at the no. 2,3,4 and 5 cylinder fuel pumps and the No. 3 generator had active leaks at the No. 2 and 4 cylinder fuel pumps. Also leaks were found at the sight glass on the piping leading from the HFO tank.
74 SOLAS (04) II-2/4.1.1
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 6 January 2021
Resolved
15106- The company should establish procedures to ensure that new personnel related to safety and protection of the environment are given proper familiarization with their duties, with instructions provided prior to sailing. PSCO observed the vessel's sewage tank overflowing after reviewing daily sounding records, it was determined that the 4th extinguisher was not taking correct soundings of the tank. 4th engineer recorded in the last sounding that the tank was approximately 18 m^3, about 25% of the capacity. PSCO believes the 4th Engineer was not given proper familiarization with his duties.
74 SOLAS(14) IX/3.1
ISM CODE 6.3
Fire Fighting › Fire Hoses › Condition
Issued 23 March 2016
Resolved
0720: Firefighting appliances and systems shall be maintained ready for use. PSCO Observed that the vessels crew was unable to successfully charged the ships fire hoses with the emergency fire pump. SOLAS 14 II-2/14.1
Action Taken: 17ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National