Records from 2011 to 2012. Most recent: inspection, 13 February 2012.
Documentation record
Tonnage as PSIX records it27987 - Convention (Subpart B), Gross Ton
27987 - Simplified, Gross Ton
9851 - Convention (Subpart B), Net Ton
9851 - Simplified, Net Ton
42561 - Dead Weight, Ton
50400 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
13 February 2012
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4242975
11 February 2012
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4242479
10 February 2012
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4241857
20 September 2011
ISPS II Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 4149415
16 February 2011
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3946102
Construction/Loadline › Markings › Load Line Mark
Issued 20 September 2011
Resolved
Vessels load line mark was not contrasting colors. Make load line mark contrasting colors as per ILLC. ILLC Annex I/5
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 November 2011
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 16 February 2011
Resolved
Vessel had major non-conformities with the SMS to include: C/O not being familiiar with SMS; Improper IGS practices; Number 5 stbd tank was at 13.6% Oxygen content as opposed to the 8% required by SOLAS Fire Safety Code; and OWS usage not being properly documented. SOLAS 74 (2004) Chap. XI Reg 4.1 and ISM Code Part A Reg. 1.4 (See Form A&B)
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2011
Resolved 18 February 2011
Resolution: Vessel detainable deficiencies cleared by USCG inspectors and is cleared for cargo operations and departure.
Operations/Management › Drills/Instruction › Fire
Issued 16 February 2011
Resolved
Every crew member with assigned emergency duties shall be familiar with their duties before the voyage begins. Vessel crew failed to meet minimum requirements during the two fire drills conducted. SOLAS 74(2004) III/19.3.4
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2011
Resolved 18 February 2011
Resolution: Vessel crew were able to demonstrate adequate fire-fighting capabilities.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 16 February 2011
Resolved
Every crew member with assigned emergency duties shall be familiar with their duties before the voyage begins. Vessel crew failed to meet minimum requirements during the two abandon ship drills conducted. SOLAS 74(2004) III/19.3.3
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2011
Resolved 18 February 2011
Resolution: Crew was able to demonstrate adequate abandon ship procedures.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 16 February 2011
Resolved
Training manual shall explain all fire fighting activities and procedures in detail. Training manual does not include fire fighting procedures. SOLAS 74(2004) II-2/15.2.3.4
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 18 February 2011
Resolution: Crew located manual on board vessel.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 16 February 2011
Resolved
Fire safety operational booklets shall be provided. Fire safety operational booklets are not on board. SOLAS 74 (2004) II-2/16.1.1 and II-2/16.2
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 18 March 2011
Resolution: Class cleared def, see report in documentation section of Misle for details.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 16 February 2011
Resolved
Portable instruments for measuring oxygen and flammable vapour concentration shall be provided. Tank monitoring equipment is not in proper working condition. FSS Code Chap.15 Reg 2.4.2.4
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 18 March 2011
Resolution: Class cleared def, see report in documentation section of Misle for details.
Documentation › Logs/Records › Oil Record Book
Issued 16 February 2011
Resolved
Each operation involving discharge of bilge water shall be fully recorded without delay in the oil record book Part 1. Oil record book does not show entries for OWS usage from Dec. 29, 2010 thru Jan. 28, 2011. PSC Officer confirmed with the crew that the OWS was operated to discharge bilge water during this period and the operations were not logged in the ORB. MARPOL 73/38 Annex I CH.3 Reg 17.4
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 18 March 2011
Resolution: Class cleared def, see report in documentation section of Misle for details.