NORDIC LIGHT
NORDIC LIGHT is a 2010 tank ship. The Coast Guard has recorded 19 inspections since 2010, most recently in January 2026, along with 10 deficiencies and 2 operational controls.
Records from 2010 to 2026. Most recent: inspection, 5 January 2026.
- Built
- 2010
- Last inspected
- 5 January 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9436446 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7TQ7
1100842
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1100842
Inspections, by type
…with no type recorded3
Years with a record
13 calendar years (2010–2026)
The 19 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it81493 - Convention (Subpart B), Gross Ton
51283 - Convention (Subpart B), Net Ton
158475 - Dead Weight, Metric Ton
182850 - Displacement, Metric Ton
51283 - Convention (Subpart B), Net Ton
158475 - Dead Weight, Metric Ton
182850 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 19
5 January 2026
PSC B · COC-TVE Annual · COE-Administrative
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8286774
16 December 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8284199
10 December 2024
COC-TVE Renew
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8037557
13 June 2023
COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7699622
11 April 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7428555
4 March 2022
PSC B · COC-TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7402391
16 December 2021
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7368412
17 February 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7141727
7 February 2021
PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7128107
26 June 2019
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6719875
17 June 2019
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6716572
18 December 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6599550
15 December 2018
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6598131
9 November 2016
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6034266
4 August 2014
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4945690
13 February 2012
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4235581
9 February 2011
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3942213
9 November 2010
ISPS II Exam · COC-TVE Renew · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3881792
9 November 2010
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3885543
Deficiency record · 10
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 March 2022
Resolved
01 - In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the Organization. 6 Ex rated lights were found with significantly cracked lens in the cargo pump room. - 74SOLAS(20) Ch. II-1/45.11 - 50bc
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 March 2022
Resolved
02 - In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the Organization. #2 COP mechanical seal drain tank sensor cable was not properly packed in the sensor gland. - 74SOLAS(20) Ch. II-1/45.11 - 10C
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 4 March 2022
Resolved
03 - Vapor stud: each vessel's vapor connection flange face must have a permanent stud projecting outward. Both vapor studs were removed from the port-side vapor connection flange face. All flanges and reducers for the vapor manifold must be permanently affixed. - 46CFR39.2001 - 40c
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 4 March 2022
Resolved
04 - Tank overfill alarm: the tank overfill alarm required by paragraph (a) of this section must be identified with legend "tank overfill alarm." Overfill alarm visible from deck is incorrectly marked as "overfill." Separately, the high level alarm in the CCR needs to be marked in accordance with the same regulation. - 46CFR39.2007 - 40c
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 February 2021
Resolved
Ships shall be designed, constructed and maintained in compliance with structural, mechanical and electrical requirements of a classification society. Main switchboarrd circuit breaker suppling power to all bridge navigational equipment has failed. Vessels only capable of suppling power to bridge navigational equipment by means of the emergency generator through the emergency switchboard.
74 SOLAS(14) II-1/3-1
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 December 2018
Resolved
High level alarm must be visible and audible so that it can be seen and heard on vessel where cargo transfer is controlled. High level visual alarm on deck is not operational.
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Quantity of Foam
Issued 9 November 2010
Resolved
Vessel's foam system lost approximately 1meter cubed of low expansion foam during it's inspection. Replace lost foam in tank to its original level prior to departure from Sector San Fran.
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Control Valves
Issued 9 November 2010
Resolved
During testing of emergency fire pump system approximately 1 meter cubed of low expansion foam was discharging from its tank. Prove proper operation prior to departure from Sector San Fran.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 November 2010
Resolved
0710 Prove fire doors for engine control room are class "A-60" doors and labeled properly. SOLAS 09Ed. CH II-2 REG9.4.2 (17a prior to departure from san Francisco.)
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 9 November 2010
Resolved
2035 Update fire control plan to show all class "A" bulkheads, currently engine controle room and escape trunk do not show "A" class boundary. SOLAS 09 CE CH. II-2 REG 15.2.4.1 (70a)