Records from 2016 to 2024. Most recent: inspection, 13 June 2024.
Inspection history · 18
13 June 2024
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7934059
15 May 2024
Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7913578
7 May 2024
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7907266
9 March 2023
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7648231
9 March 2023
Simplified Stability Test
Physical examination · Marine Safety Center (MSC) · Activity 7655081
19 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7580354
22 September 2022
Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7563650
1 February 2022
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7388380
27 July 2021
Plan Review "T" Boat · Construction Oversight
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7270295
15 December 2020
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7114669
20 August 2020
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7037026
4 March 2020
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6914687
14 February 2019
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6623830
8 August 2018
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6467684
11 January 2018
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6332972
2 November 2017
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6299736
15 December 2016
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6053924
8 August 2016
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5940375
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 May 2024
No resolution recorded
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed.
All (14) pontoon sectional inspection port plugs worn and unable to seal the inspection port. Replace all (14) pontoon sectional inspection port plugs in kind.
46CFR176.840
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2024 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2024
No resolution recorded
A vessel must comply with the structural design requirements of Lloyd's Yachts and Small Craft; or ABS Vessel Rules. A 3" crack was identified on the transom framing.
Make permanent repairs to the satisfaction of the attending CG Marine Inspector.
46CFR177.300(d)
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2024 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2024
No resolution recorded
A vessel must comply with the structural design requirements of Lloyd's Yachts and Small Craft; or ABS Vessel Rules.
1/2" diameter hole, 1/4" diameter hole on the starboard rub rail and (3) 3/8" diameter holes was identified on the port rub rail.
Crop and renew wasted sections of rub rails to the satisfaction of the attending CG Marine Inspector.
46CFR177.300(d)
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2024 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2024
No resolution recorded
A vessel must comply with the structural design requirements of Lloyd's Yachts and Small Craft; or ABS Vessel Rules.
Approx. 30 sqft of decking is decayed.
Replace in kind with 3/4" XL50 marine grade plywood to the satisfaction of the attending CG Marine Inspector.
46CFR177.300(d)
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2024 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2024
No resolution recorded
#1, #10, #13, #14, #16, and #19 transverse deck stiffener structural members (cross channels) are wasted.
Replace in kind with 6061 aluminum channel, including hardware to the satisfaction of the attending CG Marine Inspector.
46CFR177.300(d)
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2024 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 May 2024
No resolution recorded
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed.
Outboard engine mount hardware was identified as loose or corroded.
Replace all outboard engine mount hardware in kind.
46CFR176.840
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2024 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2024
No resolution recorded
A vessel must comply with the structural design requirements of Lloyd's Yachts and Small Craft; or ABS Vessel Rules.
Pitting corrosion was identified on the exterior, outboard side, above the waterline on the following pontoon sections: S1, S2, S3, S4, S5, S6, P3, P4, and P5.
Due to the extent of pitting, a pressure test of all pontoon sections (S1-S7 and P1-P7) to 1.5 psi will be required in the presence of the attending CG Marine Inspector.
In addition, make all pontoon sections available for internal bore-scope examination to determine suitable service for the intended route and vessel seaworthiness.
46CFR177.300(d)
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2024 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2024
No resolution recorded
The cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs.
The OCMI may also decrease the drydock examination intervals to monitor the vessel's structural condition. Following satisfactory pressure test and bore scope examinations as specified in deficiency #07, the vessel will be granted a one year dry dock interval.
Vessel will be required to effect permanent repairs to pontoon pitting during next dry dock examination.
46CFR176.600(d)
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2024 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 May 2024
Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel was overdue for its annual inspection.
46 CFR 176.500(b)(1)
Action required: 10 - Deficiency Rectified
Resolved 7 May 2024
Resolution: Vessel completed its annual inspection.
Navigation › Piloting/Steering › Marine Charts
Issued 11 January 2018
Resolved
Provide updated charts and tide tables.
Action required: 705 - Other - as specified
Due 25 January 2018
Resolved 25 January 2018
Resolution: Photos and receipt provided.
Documentation › Certificates/Documents › Stability Letter
Issued 11 January 2018
Resolved
Post stability letter.
Action required: 705 - Other - as specified
Due 25 January 2018
Resolved 25 January 2018
Resolution: Provided MSC electronically signed copy to Placida Harbor representative.
Documentation › Markings/Placards › Warning Signs
Issued 11 January 2018
Resolved
Stencil fuel shutoff and direction of valve closure.
Action required: 705 - Other - as specified
Due 25 January 2018
Resolved 25 January 2018
Resolution: Stencils purchased.
Documentation › Markings/Placards › Warning Signs
Issued 11 January 2018
Resolved
Post EAP Substance Abuse Professional (SAP) name and contact number.
Action required: 705 - Other - as specified
Due 25 January 2018
Resolved 25 January 2018
Resolution: Consortium provided EAP SAP package and contact number.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 January 2018
Resolved
Update first aid kit.
Action required: 705 - Other - as specified
Due 25 January 2018
Resolved 25 January 2018
Resolution: New first aid kit purchased.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 January 2018
Resolved
Add retro reflective tape to ring buoy.
Action required: 705 - Other - as specified
Due 25 January 2018
Resolved 25 January 2018
Resolution: Retro reflective tape added to ring buoy.