Records from 1992 to 2026. Most recent: inspection, 14 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 55
14 May 2026
Drydock Exam · Vessel Attendance · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8372850
3 September 2025
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8225956
29 November 2023
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7831388
31 October 2022
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7580859
17 February 2022
Examination of Repairs · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7389412
20 September 2021
COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7257925
27 October 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7073832
7 May 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6944376
8 October 2019
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6820570
16 October 2018
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6552989
12 April 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6378639
17 October 2017
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6277997
17 April 2017
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6112076
29 September 2016
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5996438
9 August 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6013243
15 April 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5835177
27 October 2015
Administrative Inspection · Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5738296
8 August 2011
DAPI Audit · COI Inspection · MARPOL Annex VI Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4109086
14 October 2010
DAPI Audit · MARPOL Annex VI Survey · Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3871871
24 April 2009
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3439681
8 September 2008
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3320915
21 September 2007
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3051868
24 May 2007
Excursion Permit
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2948450
9 April 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2904569
5 September 2006
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2769160
24 May 2006
Excursion Permit
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2657945
2 August 2005
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2436574
6 May 2004
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2058273
28 April 2004
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2053963
20 October 2003
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1930643
24 July 2003
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1855635
1 November 2002
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1696703
22 May 2002
Excursion Permit
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1619297
12 April 2002
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1494383
22 September 2001
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1387178
25 May 2001
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1063635
27 October 2000
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1464974
12 April 2000
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1440271
27 September 1999
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1444226
22 September 1998
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 799961
20 April 1998
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 791256
2 February 1998
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1121181
20 October 1996
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 854661
20 September 1996
Excursion Permit
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1146979
18 September 1996
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 961901
2 June 1996
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1136031
1 May 1996
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1133726
20 September 1995
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 877099
8 May 1995
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1345175
23 September 1994
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1359937
2 May 1994
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1356770
15 October 1993
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1409035
21 January 1993
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1141645
23 September 1992
Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1132275
20 May 1992
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1134746
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 31 October 2022
Resolved
On a vessel of at least 26ft, a visual and audible alarm must be provided at the operating station to indicate a high water. High water alarm was not able to be tested. Make rounds every 30 minutes while underway and log these in vsl logbook until operation can be proven.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2022
Resolved 20 April 2023
Resolution: Witnessed video of properly operating high water alarm with light and audible sound.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 October 2022
Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets with an attached lanyard and the words "FIRE BUCKET" stenciled in a contrasting color. Only 2 fire buckets onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2022
Resolved 4 November 2022
Resolution: Vessel has added another fire bucket.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 31 October 2022
Resolved
Each vessel that operates on the high seas must have onboard a Category 1 406 MHz EPIRB installed to automatically float free and activate. NOAA registration for EPIRB is expired. Vessel shall not operated beyond 3 miles from shore until NOAA registration has been obtained.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2022
Resolved 3 November 2022
Resolution: Found current EPIRB registration good until May 2023.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 October 2022
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel name is not on either ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2022
Resolved 3 November 2022
Resolution: Vessel name has been written on both ring life buoys.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 31 October 2022
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Life float paddles are not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2022
Resolved 3 November 2022
Resolution: Vessel name has been written on life float paddles.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 31 October 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2022
Resolved 20 April 2023
Resolution: MMSI number for the vessel matches what is in the radio.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 October 2022
Resolved
A pre-engineered fixed fas fire extinguishing system may only be installed in a normally unoccupied machinery space with a gross volume of not more than 2,000 cubic feet. Engine room space has gaps and penetrations in the bulkhead between it and the companionway. Properly secure engine space penetrations and gaps to limit flow of oxygen in the event of a fire.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2022
Resolved 11 May 2023
Resolution: Bulkhead repairs have been completed. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 October 2022
Resolved
A vessel on a lakes, bays, and sounds route must carry three red hand flares and three orange smoke distress signals. Red hand flares may be substituted for the orage smoke signals. Vessel only has 5 flares onboard.
Action required: 10 - Deficiency Rectified
Due 31 October 2022
Resolved 31 October 2022
Resolution: Vessel purchased an additional flare.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 31 October 2022
Resolved
Each EPIRB must be tested monthly. This shall be logged or otherwise documented. EPIRB testing was not logged.
Action required: 10 - Deficiency Rectified
Due 31 October 2022
Resolved 31 October 2022
Resolution: Master has placed EPIRB testing in the logbook.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 September 2021
Resolved
A vessel on a lakes, bays, & sounds route must carry 3 red hand flares and 3 orange smoke distress signals or 6 red hand flares onboard. Vessel only has 4 unexpired flares total.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2021
Resolution: Obtained 2 more red flares. All sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 September 2021
Resolved
Each vessel that operates beyond 3NM from shore must
have a Category 1, 406 MHz EPIRB installed. EPIRB hydrostatic release is expired. Vessel restricted to within 3NM until cleared.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 15 October 2021
Resolution: Hydro replaced. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 September 2021
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Ring life buoy needs retroreflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 15 October 2021
Resolution: Retro tape installed. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 September 2021
Resolved
Each vessel of more than 26' but not more than 65' must carry a minimum of one ring life buoy no less than 24" diameter. Grab lines worn and need to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 15 October 2021
Resolution: Replaced the port and stbd side ring buoys with new ones. All sat.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 20 September 2021
Resolved
If a stability letter is issued, it must be posted under glass or other suitable transparent material in the pilothouse or kept onboard in custody of the operator.
Vessel does not have stability letter or sail plan
onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 15 October 2021
Resolution: Stability letter provided to rep. Sail plan not required. All sat.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 20 September 2021
Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The flame screen shall consist of a single screen of corrosion resistant wire of at least 30X30 mesh and shall be of such size and design as to prevent reduction in the net cross-sectional area of the vent pipe and permit cleaning or renewal. No flame screens found.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 15 October 2021
Resolution: Flame screen installed. All sat.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 20 September 2021
Resolved
Each fuel tank shall be fitted with a vent pipe with a minimum net cross-sectional area of not less than 5/8". Vent pipe diameter is 1/4".
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 15 October 2021
Resolution: Proper vent pipe installed. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 20 September 2021
Resolved
A vessel must comply with applicable requirements for any radio as set forth in 47 CFR 80. Each ship transporting more than six passengers for hire equipped with a radiotelephone station must carry a radio operator who holds a marine radio operator permit or higher class license where station power does not exceed 250 watts carrier power or 1500 watts peak envelope power. Vessel master does not have a marine radio operator permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 15 October 2021
Resolution: Provided. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 September 2021
Resolved
At each inspection, all standing rigging is subject to inspection. D1 toggle on shroud, stbd side found with suspected fracture. Inspect and replace as needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 19 November 2021
Resolution: D1 toggle removed. Conducted a thorough inspection using magnifying glass. No fracture was noted only minor surface scratches. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 September 2021
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC licensed technician once every 5 years, after which a Communications Act Safety Radio telephony Certificate will be issued. Vessel does not have a current radio telephony certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 16 November 2021
Resolution: Received copy of FCC certificate. Uploaded.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 20 September 2021
Resolved
Each vessel shall be fitted with a suitable compass. No magnetic compass on-board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2021
Resolved 19 November 2021
Resolution: Magnetic compass installed and deviation card provided. All sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 September 2021
Resolved
Each EPIRB test required shall be logged. EPIRB tests not logged.
Action required: 10 - Deficiency Rectified
Resolved 20 September 2021
Resolution: Vessel master tested EPIRB and logged it.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 September 2021
Resolved
Address crack in the after ring frame, the cracked frame aft of the after ring frame (port side), and the crack in the exposed frame underneath the ladder (stbd side) to the satisfaction of the CG marine inspector at the next scheduled dry-dock, April 2022.
Action required: 705 - Other - as specified
Due 30 April 2022
Resolved 4 May 2022
Resolution: See activity #7389412
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 27 October 2020
Resolved
Buoyant apparatus not serviceable. Replace with CG approved life float.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 November 2020
Resolved 13 November 2020
Resolution: Replaced with 8-person life float
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 October 2020
Resolved
Inoperable indicating light for pre-engineered fixed gas fire extinguishing system. Demonstrate functionality to satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 November 2020
Resolved 23 November 2020
Resolution: Tested fireboy & shutoffs - all sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 8 October 2019
Resolved
50% of crew lacked CPR training.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2019
Resolved 21 October 2019
Resolution: Training completed with certificate issued.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 October 2019
Resolved
1st Aid Kit
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2019
Resolved 21 October 2019
Resolution: New first aid kit purchased and installed on vessel.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 16 October 2018
Resolved
Vessel did not have a waste management plan. Provide a waste management plan.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2018
Resolved 18 October 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 October 2018
Resolved
Vessel's fire buckets were incorrectly sized. Provide proper size fire buckets labeled with line.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2018
Resolved 18 October 2018
Lifesaving › Visual Distress Signals (General) › Expired
Issued 17 October 2017
Resolved
Provide 3 orange smoke visual distres signals.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 October 2017
Resolved 17 October 2017
Resolution: Replaced 3 orange smoke distress signals.
Documentation › Safety Management System › Essential Sailing Instructions Documentation
Issued 17 October 2017
Resolved
Provide sail rig inspection program to meet NVIC 02-16
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 31 October 2017
Resolution: Received sail rig inspection program.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 29 September 2016
Resolved
Provide a copy of the logs and passenger count to Sec SENE.
Action required: 705 - Other - as specified
Due 29 October 2016
Resolved 29 September 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 September 2016
Resolved
Update all expired items in the first aid kit.
Action required: 705 - Other - as specified
Due 29 October 2016
Resolved 29 September 2016
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 29 September 2016
Resolved
Properly post the Drug and alcohol hot line numbers.
Due 29 October 2016
Resolved 19 October 2016
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 29 September 2016
Resolved
Provide the company drug and alcohol policy.
Action required: 705 - Other - as specified
Due 29 October 2016
Resolved 19 October 2016
Communications › Alarms/Indicators › Fire Alarm
Issued 9 August 2011
Resolved
Renew Fireboy audible alarm. 46 CFR 181.420 (b)
Action required: 705 - Other - as specified
Due 16 August 2011
Resolved 23 August 2011
Construction/Loadline › Structures › Superstructure
Issued 9 August 2011
Resolved
Repair cracked gooseneck. The gooseneck fitting was cracked at the underside of the upper vang plate.
Action required: 705 - Other - as specified
Due 9 August 2011
Resolved 10 August 2011
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 14 October 2010
Resolved
Replace battery on floating waterlight.
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 3 January 2011
Resolution: Received picture of new battery for floating waterlight.
Documentation › Certificates/Documents › FCC SSL
Issued 14 October 2010
Resolved
Provide valid FCC Safety Certificate
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 15 November 2010
Resolution: Received scan of new FCC Safety Certificate.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 October 2010
Resolved
Replace leaking cooling water hose on intake side of the pump.
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 3 January 2011
Resolution: Received pictures of new hose kit and new hose elbow installed in raw water system.
Fire Fighting › Fire Bucket › Quantity
Issued 14 October 2010
Resolved
Provide 1 additional fire bucket for a total of 3 fire buckets.
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 15 November 2010
Resolution: Received scan of reciept for purchase of new fire bucket.
Communications › Radio Communications › EPIRB
Issued 21 September 2007
Resolved
EPIRB battery expired.
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 5 November 2007
Resolution: fax proof of new battery faxed in.
Documentation › Certificates/Documents › FCC SSL
Issued 21 September 2007
Resolved
Expired FCC station license.
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 5 November 2007
Resolution: Proof of FCC license faxed in.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 21 September 2007
Resolved
Fire detection system must be in accordance with either G-MOC policy letter 4-98, or replaced with an approved system (per NTSB safety recommendation M-06-11) or a fireboy system that automatically activates.
Action required: 705 - Other - as specified
Due 30 March 2008
Resolved 24 April 2008
Resolution: Vessel was returned to the water so had an opportunity to test engine operation/shutdown with new 75 cubic foot Fireboy fixed fire extinguishing system.
Lifesaving › Lifebuoys › Serviceable
Issued 19 September 2006
Resolved
Replace 1 lifering NLT 19Sept06.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2006
Resolved 6 October 2006
Resolution: Lifering bought and replaced on board vsl.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 September 2006
Resolved
Label liferings with name/hailing port NLT 26Sept06.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 September 2006
Resolved 6 October 2006
Resolution: Life rings properly labeled.
Navigation › Piloting/Steering › Marine Charts
Issued 19 September 2006
Resolved
Replace outdated Navigation Pubs NLT 26Sept06.
Action required: 705 - Other - as specified
Due 26 September 2006
Resolved 6 October 2006
Resolution: Current Nav pubs bought and replaced on board.
Operations/Management › Drills/Instruction
Issued 20 October 2003
Resolved
Conduct MOB and fire drills to the satisfaction of attending Marine Inspector. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2004
Resolved 6 May 2004
Resolution: Conducted drills sat..
Communications › Radio Communications
Issued 20 October 2003
Resolved
Replace hydro on EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2003
Resolved 6 May 2004
Resolution: Bought hydro
Documentation › Certificates/Documents
Issued 20 October 2003
Resolved
Provide FCC safety certificate. LEGACY COMPONENT DESC: FCC SSL
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2003
Resolved 6 May 2004
Resolution: Had safety cert. done.
Lifesaving
Issued 27 October 2000
Resolved
Nylon webbing for ring buoy's grab lines are dry-rotted, needs replacement.
Condition: Unknown
Due 27 October 2000
Resolved 27 October 2000
Fire Fighting
Issued 27 October 2000
Resolved
Service all fire extinguishers(wiegh/test) IAW 46CFR176.810.
Condition: Unknown
Due 27 October 2000
Resolved 27 October 2000
Lifesaving
Issued 27 October 2000
Resolved
Vessel is restricted to no more than 3NM from shore until a 406MHZ EPIRB isinstalled.
Condition: Unknown
Due 27 October 2000
Resolved 27 October 2000
Lifesaving
Issued 2 February 1998
Resolved
CONDUCT SATISFACTORY U/W OPERATIOAL TEST OF THE VESSEL INCLUDING DRILLS WITHIN 10 TEN DAYS OF PLACING THE VESSEL IN SERVICE FOR THE 1998 SEASON.
Condition: Unknown
Due 2 February 1998
Resolved 2 February 1998
Lifesaving
Issued 20 September 1995
Resolved
CONDUCT SATISFACTORY UNDERWAY/OPERATIONAL TEST OF VESSEL INCLUDING DRILLS PRIOR TO CARRYING PASSENGERS IN THE 1996 SEASON.
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Documentation
Issued 23 September 1992
Resolved
PROVIDE PROOF THAT THE VESSEL'S CREW HAS BEEN ENROLLED IN A RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 7 October 1992
Resolved 17 November 1992
Documentation
Issued 23 September 1992
Resolved
PROVIDE A COPY OF THE VESSEL'S WASTE MANAGEMENT PROGRAM.
Condition: Unknown
Due 7 October 1992
Resolved 17 November 1992
Construction/Loadline
Issued 23 September 1992
Resolved
INSTALL VENTILATION IN THE ENGINE COMPARTMENT AS REQUIRED BY 46 CFR 182.20 -45.
Condition: Unknown
Due 23 September 1992
Resolved 23 September 1992