MAURY USCG vessel records
← All vessels

V TAURUS

V TAURUS is a freight ship. The Coast Guard has recorded 11 inspections since 2016, most recently in March 2026, along with 6 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 2 March 2026.

Built
Not recorded
Last inspected
2 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9496161
3E2269
1101399
Flag
PANAMA
Maury page id
psix-1101399

Inspections, by type

…with no type recorded2
Years with a record 7 calendar years (2016–2026)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it33193 - Dead Weight, Metric Ton
40829 - Displacement, Metric Ton
21483 - Convention (Subpart B), Gross Ton
10828 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 11

2 March 2026 PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8318633
2 January 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8056847
18 December 2024 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8048843
24 January 2024 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7853815
23 December 2022 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7612434
16 December 2022 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7608719
14 December 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7609269
23 April 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7179803
22 April 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7178894
25 April 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6126435
7 August 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5964592

Deficiency record · 6

11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 2 March 2026 Resolved
AN IMMERSION SUIT WHICH HAS BUOYANCY AND IS DESIGNED TO BE WORN WITHOUT A LIFEJACKET SHALL BE FITTED WITH A LIGHT COMPLYING WITH THE REQUIREMENTS OF PARAGRAPH 2.2.3 AND THE WHISTLE PRESCRIBED BY PARAGRAPH 2.2.1.14. SEVERAL IMMERSION SUITS DID NOT COMPLY TO THIS STANDARD, LACKING TIED ON LIGHTS AND WHISTLES.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 March 2026
Resolved 2 March 2026
Resolution: RECTIFIED ON THE SPOT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 March 2026 Resolved
LIFEBUOYS COMPLYING WITH THE REQUIREMENTS OF PARAGRAPH 2.1.1 OF THE CODE SHALL BE STOWED AS TO BE CAPABLE OF BEING RAPIDLY CAST LOOSE. THE LIFEBUOY LIGHTS AND BUOYANT LIFELINE'S STOWAGE PROHIBITED RAPID DEPLOYMENT.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 2 March 2026
Resolved 2 March 2026
Resolution: RECTIFIED ON SITE
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 2 March 2026 Resolved
INTERNATIONAL SHORE CONNECTION SHALL HAVE A GASKET OF ANY MATERIAL SUITED FOR SHIP SERVICES. THE PROPER GASKET WAS NOT AVAILABLE.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 2 March 2026
Resolved 2 March 2026
Resolution: RECTIFIED ON THE SPOT
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 16 December 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel Master reported smoke detector in #5 cargo hold is inoperable. 74 SOLAS 20 I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2022
Resolved 22 December 2022
Resolution: Received Masters statement and class information contesting to the deficiency correction.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 April 2017 Resolved
PSCO noticed oily soaked rags and buckets of fuel in engine room storage space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 26 April 2017
Resolution: Ship captain provided proof of condition being resolved
Engineering › Fuel Oil Service System › Piping
Issued 25 April 2017 Resolved
Chief Engineer could not provide proof that lines had been pressure tested with use of liquid.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 April 2017
Resolution: Ship Captain provided proof of hydrostatic testing

Ownership record