MAURY USCG vessel records Sign in
← All vessels

DEDALOS

DEDALOS is a 2009 freight ship. The Coast Guard has recorded 6 inspections since 2015, most recently in April 2026, along with 4 deficiencies and 1 operational control.

Records from 2015 to 2026. Most recent: inspection, 26 April 2026.

Built
2009
Last inspected
26 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9487873 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA4992
1101488
Flag
MALTA
—
Maury page id
psix-1101488

Inspections, by type

…with no type recorded1
Years with a record 5 calendar years (2015–2026)
The 6 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it51209 - Convention (Subpart B), Gross Ton
30733 - Convention (Subpart B), Net Ton
108709 - Displacement, Metric Ton
93037 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 6

26 April 2026 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8355884
28 September 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7799976
1 May 2018 Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6400038
8 September 2016 NPV Safety Exam · Random ISPS/MTSA/PSC · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5995186
16 August 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5974053
25 November 2015 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5766545

Deficiency record · 4

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 26 April 2026 Resolved
Emergency generating sets shall be capable of being readily started in their cold condition at a temperature of 0 degrees Celsius. PSCO observed emergency generator having to be manually adjusted to start. 74SOLAS(24) II-I/44.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 April 2026
Resolution: Received class report attesting to proper operation.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 26 April 2026 Resolved
The administration shall take steps to ensure that crews are trained in use of such instruments. PSCO identified crew using incorrect regulator for gas detection equipment. 74 SOLAS (24) VI/3.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2026
Resolution: Received class report stating proper regulator onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2023 Resolved
The machinery boilers, and other pressure vessles associateed piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed active jacket water leak on M/E cylinder No. 6. 74 SOLAS 20/II-I 26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 October 2023
Resolved 17 October 2023
Resolution: Master provided satisfactory class report attesting to repair of jacket water leak on M/E cylinder #6. O-rings and gaskets were replaced by new ones on cooling jacket of cyl's liner and cover.
Electrical › Electrical Distribution System (emergency) › Ground Indicator
Issued 27 November 2015 Resolved
1499-prop. & aux. Machinery - electrical installations shall be safe under all emergency conditions. PSCO discovered ground fault on 220V feeder panel for the egen swbd. Ship's crew had not prviously reported the fault. SOLAS '09 CONS II-1/40.1.2.
Due 11 December 2015
Resolved 28 November 2015
Resolution: Received, reviewed and accepted class report / proper documentation from LR stating the deficiency was rectified. Cable was repaired and properly connected.

Ownership record