SARANGA is a 2006 tank ship. The Coast Guard has recorded 10 inspections since 2011, most recently in October 2020, along with 12 deficiencies and 1 operational control.

Records from 2011 to 2020. Most recent: inspection, 30 October 2020.

Built
2006
Last inspected
30 October 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9349643 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1101570
Flag
SINGAPORE
—
Maury page id
psix-1101570

Inspections, by type

…with no type recorded1
Years with a record 7 calendar years (2011–2020)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6378 - Convention (Subpart B), Net Ton
12105 - Convention (Subpart B), Gross Ton
20938 - Dead Weight, Ton
26506 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 10

30 October 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7085354
13 November 2017 COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6305643
13 October 2017 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6287160
29 October 2016 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6028651
21 November 2015 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5767878
14 October 2014 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5004948
26 May 2014 COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4863262
17 January 2012 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4225795
16 January 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4225439
17 February 2011 ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3944887

Deficiency record · 12

01 - Certificates & Documentation › 011 - Ships Certificates › Cargo ship safety equipment (including exemption)
Issued 30 October 2020 Resolved
Freefall lifeboat has exposed fiberglass on the port and stbd corners. 74SOLAS(14), CH I, Reg 11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2020
Resolution: See class report
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 30 October 2020 Resolved
The previous classification society to which the vessel was classed is permanently affixed on the ship hull. The current classification society is denoted using paint and is therefore not permanently affixed. ICLL 7
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2020
Resolution: See class report
Documentation › Logs/Records › Garbage Recordkeeping
Issued 17 February 2011 Resolved
Code: 2120: Garbage Plan; Persons collecting lights and batteries not identified in plan. Person in charge of expired medicine not part of plan.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 March 2011
Resolved 18 March 2011
Resolution: Received class report correcting deficiency.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 17 February 2011 Resolved
2510: Ballast Water Management Plan, vsl has two plans one from Class and one from company. Crew training is not being carried out. Ballast Water handling log forms are not being filled out. Sediment documentation forms are being used for cargo ops. Vsl has two different ballast water handling log forms, one for cargo one for BWM plan, which need to separated.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 March 2011
Resolved 18 March 2011
Resolution: Received class report correcting deficeincy.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 17 February 2011 Resolved
1999: SMPEP; Section 3.3.2, local contacts is not being filled out in Appendix I. Pro-Forma form is not being used. Section 3.3.3, ship contacts being filled in with company form, which is not identified in the plan. Appendix I and II are being combined.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 March 2011
Resolved 18 March 2011
Resolution: Received class report correcting item.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 17 February 2011 Resolved
0950: Company must provide documentation that rubber matting on-board meets safety regulation for use in front of electrical panels.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 March 2011
Resolved 18 March 2011
Resolution: Received class report correcting item.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 17 February 2011 Resolved
0610: Free fall lifeboat air bottles; air bottles are being held in place with a metal bracket and rope tied around control valves. Class must ensure bottles are properly secured to prevent movement aft.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2011
Resolution: Received satisfactory class (NKK) report, dated 18FEB2011.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 17 February 2011 Resolved
0615: Rescue boat; Engine starts but no water is being pumped through to keep from overheating. Class must ensure safe operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2011
Resolution: Received satisfactory class (NKK) report, dated 18FEB2011.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 17 February 2011 Resolved
1830: Cargo Transfer Procedures do not meet the Code of Federal Regulation requirements. Gave sample copy of same to the Captain and [name withheld].
Action required: 705 - Other - as specified
Resolved 17 February 2011
Resolution: Resolved same date gave sample copy of procedures to Captain and Chief Engineer.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 17 February 2011 Resolved
0371: [name withheld] stretcher in ballast pump room is rotten and will not support a person being lifted.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 March 2011
Resolved 18 March 2011
Resolution: Received class report clearing deficiency.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 17 February 2011 Resolved
0371: Control medicines must be kept secured. Cabinets in hospital space were not kept locked. Medical kit in ECR, expired medicines.
Action required: 705 - Other - as specified
Resolved 17 February 2011
Resolution: Resolved this date, discussed with Captain and Medical Officer.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 17 February 2011 Resolved
1820: Space Entry Permit, form DTD 27.7/09 S-12, was not properly filled out prior to entry. False notification; inadequate lighting not addressed.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 February 2011
Resolution: Resolved this date, discussed with [name withheld] and Third Officer.

Ownership record