MAURY USCG vessel records Sign in
← All vessels

KWK PROVIDENCE

KWK PROVIDENCE is a freight ship. The Coast Guard has recorded 1 inspection in 2014, along with 1 deficiency.

Records in 2014. Most recent: inspection, 30 May 2014.

Built
Not recorded
Last inspected
30 May 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9263356 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V2470
1101593
Flag
HONG KONG
—
Maury page id
psix-1101593

Inspections, by type

Years with a record 1 calendar year (2014)
The 1 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it88856 - Convention (Subpart B), Gross Ton
58086 - Convention (Subpart B), Net Ton
175531 - Dead Weight, Ton
197771 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 1

30 May 2014 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4874088

Deficiency record · 1

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 May 2014 Resolved
On oily water seperator, there is a valve on line going to bilge tank between manual 3-way valve and hopper. This valve is not marked on any diagram made available to PSC examiner.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 July 2014
Resolution: Received ABS survey report clearing deficiency.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.