PRIMORSKY PROSPECT

PRIMORSKY PROSPECT is a 2010 tank ship. The Coast Guard has recorded 5 inspections since 2016, most recently in May 2021, along with 1 deficiency.

Records from 2016 to 2021. Most recent: inspection, 13 May 2021.

Built
2010
Last inspected
13 May 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 May 2021
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9511533
1101599
Flag
LIBERIA
Maury page id
psix-1101599

Documentation record

Tonnage as PSIX records it35399 - Convention (Subpart B), Net Ton
35399 - Simplified, Net Ton
62504 - Simplified, Gross Ton
62504 - Convention (Subpart B), Gross Ton
113860 - Dead Weight, Metric Ton
135071 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

13 May 2021 PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7191537
7 May 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7191541
28 July 2016 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5955406
5 May 2016 Administrative Inspection · COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5869493
13 April 2016 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5849840

Deficiency record · 1

02 - Structural Conditions › N/A - No Subsystem › Cargo pumproom
Issued 13 May 2021 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect, unloess the Administration is satisfied that such equipment is appropriately certified for safe usage in the vapours likely to be encountered. Temperature sensors for ballast pumps found with loose electrical connections in cargo pump room. 74 SOLAS (14 Cons.) II-1/45.10.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 May 2021