VS PROMISE is a 2007 tank ship. The Coast Guard has recorded 22 inspections since 2016, most recently in July 2025, along with 11 deficiencies and 1 operational control.
Records from 2016 to 2025. Most recent: inspection, 7 July 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it22444 - Convention (Subpart B), Net Ton 42010 - Convention (Subpart B), Gross Ton 73669 - Dead Weight, Metric Ton 89344 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 22
7 July 2025COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8178179
20 May 2024COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7915582
23 April 2024In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7900437
21 November 2023Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7826057
16 November 2023COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7825910
16 November 2023Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7826223
15 October 2023PSC B · Administrative Inspection · COC-TVE Renew
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 September 2020
Resolution: PSC received updated documentation for Second Officer, provided in document section.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 September 2019Resolved
The ring, lines, and letters shall be painted in white or yellow on a dark ground or in black on a light ground. They shall also be permanently marked on the sides of the ship to the satisfaction of the Administration. The marks shall be made for this purpose. PSCO observed the deckline on the port side and the plimsol mark on the starboard side to lack contrasting colors.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 September 2019
Resolution: Received class report attesting to satisfactory repairs
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 September 2019Resolved
For tankers of 20,000 tonnes deadweight and upwards, a fixed deck foam fire-extinguishing system shall be provided complying with the provisions of the Fire Safety Systems Code. The distance from the monitor to the farthest extremity of the protected area forward of that monitor shall not be more than 75% of the monitor throw in still air conditions. PSCO observed the fourth monitor from the bow was inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 September 2019
Resolution: Recieved Class report attesting to satisfactory repairs.
01 Vent outlets shall be so arranged that the vapor mixture is discharged vertically upwards. PSCO audibly observed vapor leaking from 2P, 4P, 5P, 1P, 2S, 4S, 6S, ROT P/V valves. 74 SOLAS (09) II-2/4.5.3.4.2 50ac
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 August 2018
Resolution: Received and reviewed ABS report.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 20 June 2018Resolved
02 Audible and visual alarms shall be provided...to indicate oxygen content in excess of 5% by volume. PSCO observed the oxygen content alarm set to 6% by volume. 74 SOLAS (09) II-2/4.5.5.1.1 FSS Code 15.2.2.4.5.1.1 10c
Construction/Loadline › Markings › Winter Load Line
Issued 20 June 2018Resolved
03 Load lines shall be permanently marked on the sides of ships. The winter load line was hand painted and is not permanently marked, this did not match the load line certificate. ICLL (Proto 88) 8 10c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 10 July 2018
1410 / 74SOLAS(04) II-I/26.4 / 60ac Means shall be provided to ensure that the machinery can be brought into operation from the dead ship condition without external aid. Vessel experienced a loss of propulsion, and was unable to regain, while attempting to get underway to depart the port.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 October 2017
Resolution: Recieved Class report attesting to the proper repair and operation of the ships main propulsion. Report stated that the local engine control unit (ECU) was not receiving power due to a tripped fuse caused by a power cable being chaffed and grounded.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 12 September 2016Resolved
Inspectors found deck water seal unable to hold water due to multiple holes and soft patches.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2016
Resolution: See attached class report.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 12 September 2016Resolved
Inspectors were unable to verify proper operation of the IGS due to deck water seal failure.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2016
Resolution: See attached class report.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 12 September 2016Resolved
Inspectors found seepage and multiple soft patches not approved by class on the sewage treatment plant.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 October 2016
Resolution: Affected areas were cropped and renewed to the satisfaction of Class. See attatched Class report.
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 September 2016Resolved
Inspector found multiple leaks in the salt water cooling system.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 October 2016
Resolution: New valves were welded and replaced to the satisfaction of Class. See attatched Class report.