Records from 2016 to 2019. Most recent: inspection, 1 October 2019.
Inspection history · 17
1 October 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6826553
1 October 2019
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6828272
2 May 2019
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6674875
26 March 2019
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6649699
21 January 2019
Administrative Inspection · COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6612652
20 January 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6612741
4 October 2018
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6555443
4 October 2018
Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6555445
7 August 2018
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6503327
15 June 2018
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6447921
29 May 2018
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6427398
9 May 2018
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6414761
20 June 2017
COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6181097
12 May 2017
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6143218
3 May 2016
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5868076
17 January 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5798869
10 January 2016
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5792015
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 October 2019
Resolved
Vessel punctured the sideshell when it collided with the Snell Lock.
Action required: 10 - Deficiency Rectified
Resolved 1 October 2019
Resolution: Prior to departing the lock, the vessel's class society ABS issued a condition of class for permanent repairs in Montreal, Canada.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 May 2017
Resolved
1730 - The oil content meter has an error that it is not receiving a signal from the oil content cell. Chief engineer has entered a failure of equipment entry in the oil record book and flag has issued a dispensation letter. MARPOL ANNEX I Regulation 14.7 - 40A
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 May 2017
Resolved 15 May 2017
Resolution: PSC NOLA received a class report from ABS satisfying the requirement.
Navigation › Collision/Grounding Avoidance › Radar
Issued 3 May 2016
Resolved
1530-All ships of 300gt and upwards shall be fitted with a 9 ghz radar or other meand to determine and display the range and bearing of radar transponders and of other surface craft, obstructions, nuoys, shorelines and navigational marks to assist in navigation and in collision avoidance. X- band radar receiver is not capable of receiving signal. SOLAS 14 V/ 19.2.3.2 10AC
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 3 May 2016
Resolution: PSC and class witnessed proper operation of x-band radar.