NORDIC C is a 2009 tank ship. The Coast Guard has recorded 18 inspections since 2016, most recently in April 2026, along with 5 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 7 April 2026.

Built
2009
Last inspected
7 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 April 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9441192
1101838
Flag
LIBERIA
Maury page id
psix-1101838

Documentation record

Tonnage as PSIX records it22454 - Convention (Subpart B), Net Ton
42010 - Convention (Subpart B), Gross Ton
73766 - Dead Weight, Metric Ton
89320 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

7 April 2026 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8344224
7 July 2025 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8174021
11 June 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8157072
22 November 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8038759
28 June 2024 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7943679
22 September 2023 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7796754
19 April 2023 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7671272
10 April 2022 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7427846
12 March 2020 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6925376
7 March 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6922347
4 March 2020 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6920326
11 October 2018 COE-Administrative
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6556430
3 April 2018 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6377604
26 September 2017 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6276947
21 September 2017 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6271878
19 March 2017 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6103053
2 April 2016 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5838778
7 February 2016 COE-Dockside
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5809431

Deficiency record · 5

14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 28 June 2024 Resolved
Each incinerator on a ship constructed on or after 01 January 2000 shall meet the requirements contained in appendix IV to this Annex. Each incinerator subject to this paragraph shall be approved by the Administration taking into account the standards developed by the organization. PSCO observed that the refractory brick in the incinerator was significantly deteriorated. MARPOL VI/16.6.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 July 2024
Resolution: PSCO observed class survey report attesting to repairs made to the incinerator refractory brick. All sat.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 28 June 2024 Resolved
The protection of the cargo tanks shall be achieved by a fixed inert gas system IAW the requirements of the Fire Safety Systems Code. The inert gas system shall be designed, constructed, and tested to the satisfaction of the administration. It shall be designed to be capable of rendering and maintaining the atmosphere of the relevant cargo tanks non-flammable. PSCO observed IGS not functioning properly IAW design specifications, to include inoperable blowers and valves in automatic mode. 74 SOLAS (20) 11-2/4.5.5.1.1 FSS CODE 15.2.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2024
Resolution: PSCO observed class survey report attesting to repairs made to the IGS. PSCO conducted follow-up exam on vessel and witnessed satisfactory operation and testing of IGS. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 28 June 2024 Resolved
All electrical apparatus shall be constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed an unauthorized modification to batteries in the emergency generator room. 74 SOLAS (04) 11-1/45.1.3
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2024
Resolution: PSCO observed class survey report attesting to repairs made to the emergency generator battery casing. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 28 June 2024 Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected to. PSCO observed excessive steam leak in engine room in vicinity of engine control room. 74 SOLAS (04) 11-1/33.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2024
Resolution: PSCO observed class survey report attesting to repairs made to the steam line. All sat.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 19 April 2023 Resolved
The inert gas system shall be designed, constructed and tested in accordance with the fire safety sytems code. Special consideration shall be given to the design and location of scrubber and blowers with relevant pipping and fittings in order to prevent flue gas leakages into enclosed spaces. PSCO observed water and flue gas leakage at crack at the inlet into the scrubber chamber.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 April 2023
Resolution: Vessel conducted temporary weld repairs, operational tests were satisfactory. Oustanding Condition of Class has been created, permanant repairs to be completed within 30 days. Code 60 has been cleared.