MAURY USCG vessel records Sign in
← All vessels

MAERSK PHOENIX

MAERSK PHOENIX is a 2005 tank ship. The Coast Guard has recorded 4 inspections since 2015, most recently in January 2017, along with 6 deficiencies.

Records from 2015 to 2017. Most recent: inspection, 18 January 2017.

Built
2005
Last inspected
18 January 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9283291 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1102008
Flag
SINGAPORE
—
Maury page id
psix-1102008

Inspections, by type

…with no type recorded1
Years with a record 3 calendar years (2015–2017)
The 4 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it61724 - Convention (Subpart B), Gross Ton
32726 - Convention (Subpart B), Net Ton
129641 - Displacement, Metric Ton
109571 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 4

18 January 2017 NPV Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6072501
18 January 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6114343
8 December 2016 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6054087
12 December 2015 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5776108

Deficiency record · 6

Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 8 December 2016 Resolved
Each vapor connection flange face must have a permanent stud projecting outward that has a 1/2 in diameter and is at least 1 in long. Vessel's vapor collection flange studs on port and starboard side manifold were missing or showing signs of major corrosion. 46 CFR 39.2001(j) / 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 January 2017
Resolution: A marine inspector attended the vessel and verified the vessel's vapor collection flange studs on port and stbd side manifolds. The studs were replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 12 December 2015 Resolved
1820 - Cargo Pumps - The condition of the ship and it's equipment shall be maintained to conform with provisions of the present regulations. PSCO observed electrical wiring exposed and not properly fast in the tempature sensing couplings on the #1 & #2 cargo pumps in the pump room. 74 SOLAS (am) I/11
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2015
Resolved 16 December 2015
Resolution: Received, reviewed, and accepted class report from Lloyds Register. See narrative for details.
Personnel › Training › Electricity
Issued 12 December 2015 Resolved
0810-Personal equipment-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed the emergency generator's secondary hydraulic starting mechanism absent from its stowage location. SOLAS 74(am)I/11.a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 December 2015
Resolved 16 December 2015
Resolution: Received, reviewed, and accepted class report from Lloyds Register. See narrative for details.
Electrical › Lighting (service) › Grounding Conductor
Issued 12 December 2015 Resolved
1820-Cargo pump room- Ships shall be designed, constructed and maintained in compliance with the structural mechanical and electrical requirements of classification society. PSCO observed several lighting fixtures missing grounding straps within the cargo pump room.- SOLAS 74(am) II-1/3.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2016
Resolved 16 December 2015
Resolution: Received, reviewed, and accepted class report from Lloyds Register. See narrative for details.
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 12 December 2015 Resolved
0999-Other (safety general)- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed two minor hydraulic leaks which were not being maintained by crew located outside of containment on both the forward and aft mooring arrangements- SOLAS 74(am) I/11.a
Condition: Improper/Lack of Maintenance
Due 13 December 2015
Resolved 13 December 2015
Resolution: Valve packing was tightened and issues corrected on the spot.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 12 December 2015 Resolved
0999-Other (safety in general)- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed the ventilation dampener for the emergency generator was inoperable when spot checked. -SOLAS 74(am) I/11.a
Condition: Improper/Lack of Maintenance
Due 13 December 2015
Resolved 13 December 2015
Resolution: Chief Engineer was able to free frozen fire dampener and exercise multiple times to the satisfaction of the PSCO.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.