This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it61724 - Convention (Subpart B), Gross Ton 32726 - Convention (Subpart B), Net Ton 129641 - Displacement, Metric Ton 109571 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 3
18 January 2017NPV Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6072501
18 January 2017Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6114343
8 December 2016COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Each vapor connection flange face must have a permanent stud projecting outward that has a 1/2 in diameter and is at least 1 in long. Vessel's vapor collection flange studs on port and starboard side manifold were missing or showing signs of major corrosion. 46 CFR 39.2001(j) / 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 January 2017
Resolution: A marine inspector attended the vessel and verified the vessel's vapor collection flange studs on port and stbd side manifolds. The studs were replaced.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.