Records from 2016 to 2026. Most recent: inspection, 1 April 2026.
Inspection history · 17
1 April 2026
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8338787
16 March 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8327119
8 October 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8248755
7 April 2025
PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8105150
6 December 2023
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7834320
7 June 2023
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7697136
21 September 2022
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7562586
14 May 2022
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7450431
20 April 2022
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7431605
27 April 2021
PSC B · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7183394
27 April 2021
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7184129
28 September 2019
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6820489
27 October 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6293252
23 October 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6293466
2 May 2016
Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5867452
28 April 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5858617
25 January 2016
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5799643
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2022
Resolved
Means shall be provided to control leaks of flammable liquids. PSC Examiner witnessed oil and oily rag inside interior base of the #2 fuel oil circulation pump. 74 SOLAS (20)Chap II-2 Reg 1.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2022
Resolved 13 May 2022
Resolution: Overhaul completed on No.2 fuel circulating pump. Class survey complete.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2022
Resolved
After any survey of the ship, under regs 7,8,9 or 10 has been completed, no change shall be made in the structural arrangements of the machinary equipment and other items covered by the survey without the sanction of the administration. PSC Examiner observeredrachet straps on the fuel oil circulator viscosity pump and the fuel oil purifier piping adjacent to the control panel. 74 SOLAS (20)Chap 1 Reg 11/B
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2022
Resolved 13 May 2022
Resolution: Straps removed, approval conducted through class survey.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2022
Resolved
After any survey of the ship, under regs 7,8,9 or 10 has been completed, no change shall be made in the structural arrangements of the machinary equipment and other items covered by the survey without the sanction of the administration. PSC Examiner observed added ducting above 02 generators. 74 SOLAS (20) Chap 1 11/B
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2022
Resolved 13 May 2022
Resolution: Air ducts removed, class survey attests that enough ventilating air is supplying No.1,2&3 generators.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 April 2021
Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO observed multiple power cords were connected to each other coming from one outlet on the bridge.
74 SOLAS (04) II-1/40.1.3
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 June 2021
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 April 2021
Resolved
The machinery, and associated piping systems and fitting shall be of design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and environmental conditions on bard. PSCO observed excessive LSMGO accumulation around the No. 7 M/E cylinder fuel pump.
74 SOLAS (04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 June 2021
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 27 April 2021
Resolved
Oil residue may be disposed of directly from the oil residue tanks to other acceptable means which shall be annotated in item 3.2 of the supplement to IOPP certificate Form A. PSCO observed multiple entries in the oil record book pt. 1 for evaporation of oil residues from waste oil tanks 1 & 2. IOPP supplement Form A does not list evaporation as an acceptable means of disposal of oil residues.
MARPOL I/12.2
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 June 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 September 2019
Resolved
An organized system of vehicular and pedestrian traffic control shall be established and maintained at each entrance, exit ramp and on ramps within the vessel as traffic warrants. Stevedores are not following patterns.
29CFR1918.86(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 September 2019
Resolved 28 September 2019
Resolution: Ensured that vehicles were following vessel traffic rules and laws
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 September 2019
Resolved
Power driven vehicles used in Ro-Ro operations shall be operated at speeds that are safe for prevailing conditions. Stevedores are creating an unsafe environment onboard.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 28 October 2019
Resolved 28 October 2019
Resolution: Ensured that vehicles were following vessel traffic rules and laws