← All vessels
ARIANDA
ARIANDA is a 2010 freight ship. The Coast Guard has recorded 12 inspections since 2014, most recently in December 2025, along with 8 deficiencies and 2 operational controls.
Records from 2014 to 2025. Most recent: inspection, 8 December 2025.
- Built
- 2010
- Last inspected
- 8 December 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9537276 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8VJ7
1102161
Flag
LIBERIA
—
Maury page id
psix-1102161
Inspections, by type
…with no type recorded2
Years with a record
5 calendar years (2014–2025)
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it24050 - Convention (Subpart B), Gross Ton
12150 - Convention (Subpart B), Net Ton
37495 - Dead Weight, Ton
46916 - Displacement, Ton
12150 - Convention (Subpart B), Net Ton
37495 - Dead Weight, Ton
46916 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
8 December 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8279300
31 August 2023
PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7773991
10 October 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7330087
5 August 2021
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7278287
8 July 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7238143
11 February 2021
Administrative Inspection · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7134183
29 September 2017
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6277801
28 September 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6277260
27 September 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6276578
9 September 2017
Ballast Water Examination · ISPS II Exam · Administrative Inspection · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6258984
6 September 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6261213
2 March 2014
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4831145
Deficiency record · 8
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 11 February 2021
Resolved
The siting and installation of accumulator batteries which provide a reserve source of energy shall be such as to ensure safety. PSCO observe multiple splices of various gauge sizes on the GMDSS accumulator battery wiring.
74 SOLAS (20) IV/13.7.3
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 February 2021
Resolved
The function of fixed fire detection system shall be periodically tested by means of equipment producing phenomena associated with incipient fires to which the detector is designed to respond. PSCO observed crew using a cigarette lighter to test flame detectors.
74 SOLAS (09) 11-2/7.3.2
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 9 September 2017
Resolved
2490-Interlock should be installed to prevent the ash door from opening while burner is in progress or while furnace temp is above 220 degrees C. It was found that the interlock was not operational. MARPOL VI/16.6.1
Engineering › Generator (propulsion-electric) › Winding
Issued 9 September 2017
Resolved
1460-The machinery shall be of a design and construction adequate for service for which they are intended and shall be so installed and protected as to reduce any danger to persons from moving parts, hot surfaces & other hazards. It was found that the bull gear between the prime mover and the gen has a large opening where persons could make contact with rotating machinery. 74SOLAS(09) II-1/26.1
Construction/Loadline › Structures › Deck Plating
Issued 9 September 2017
Resolved
1160-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regs to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO noted structural toe brackets on cargo holds 2, 4, and 5 slightly buckled at deck plating connection. 74SOLAS(14)I/11(a)
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 9 September 2017
Resolved
2199-To discharge ballast into waters of the U.S. a vessel subject to 151.2025 of this subpart must either ensure BW meets the BW discharge standard in 151.2030(a) use an AMS or ballast from a US PWS according to schedule in Para(b).PSCO noted vessel drydock in January 2016 and did not install a BWTS or receive extension. 33CFR151.2035(a)
Communications › Alarms/Indicators › Speed/Distance Indicator
Issued 9 September 2017
Resolved
1510-All ships of 300 GT and upwards shall have a speed and distance measuring device. PSCO noted speed log inoperable. 74SOLAS(14)V/2.3.4
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 2 March 2014
Resolved
On March 06, 2014, M/V BULK ECUADOR transited through the Western Alaska Captain of the Port zone while enroute to a U.S. port without a valid Geographic Specific Appendix for Western Alaska in its non-tank vessel response plan.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.