PLATA GLORY is a 2009 tank ship. The Coast Guard has recorded 2 inspections since 2020, most recently in September 2024, along with 2 deficiencies — 2 with no resolution recorded —.
Records from 2020 to 2024. Most recent: inspection, 16 September 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it156651 - Regulatory (Subpart C or D), Gross Ton 98944 - Regulatory (Subpart C or D), Net Ton 156651 - Convention (Subpart B), Gross Ton 98944 - Convention (Subpart B), Net Ton 297974 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 2
16 September 2024PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7990246
16 July 2020COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7003322
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 September 2024No resolution recorded
NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHERE FLAMMABELE MIXTURES ARE LIABLE TO COLLECT... UNLESS THE ADMINISTRATION IS SATISFIED THAT SUCH EQUIPMENT IS: APPROPRIATE FOR THE SPACE CONCERNED . PSCO OBSERVED 07 CRACKED LENSES IN THE PUMP ROOM.
74 SOLAS(04) II-I/45.10.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 September 2024No resolution recorded
THE CONDITION OF THE SHIP AND IT'S EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. PSCO OBSERVED BOUNDING BROKEN ON THE #1 AND #2 HYDRAULIC VALVE BOXES. 74 SOLAS(20) I/ 11(A)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.