MAURY USCG vessel records Sign in
← All vessels

NORDIC CROSS

NORDIC CROSS is a 2010 tank ship. The Coast Guard has recorded 14 inspections since 2010, most recently in October 2024, along with 2 deficiencies and 5 operational controls.

Records from 2010 to 2024. Most recent: inspection, 23 October 2024.

Built
2010
Last inspected
23 October 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9438418 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1102197
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1102197

Inspections, by type

…with no type recorded4
Years with a record 9 calendar years (2010–2024)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it51283 - Regulatory (Subpart C or D), Net Ton
81493 - Convention (Subpart B), Gross Ton
51283 - Convention (Subpart B), Net Ton
182850 - Displacement, Metric Ton
158475 - Dead Weight, Metric Ton
81493 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

23 October 2024 COE-Administrative · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8023357
1 February 2024 PSC B · Administrative Inspection · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7859040
1 October 2022 PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7564969
23 March 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7417217
19 March 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7414669
12 May 2021 COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7191769
3 September 2019 ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6802244
11 April 2019 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6660233
29 November 2018 Deficiency Check · ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6588885
23 November 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6585556
22 November 2017 COC-TVE Renew · ISPS II Exam · Ballast Water Examination · COE-Offshore
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6306770
9 January 2012 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4213916
1 September 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4125984
25 November 2010 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3890166

Deficiency record · 2

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 29 November 2018 Resolved
SOLAS II-1/44.2 - Emergency genaerator did not have a functional second means of starting, spring unit failed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2018
Resolution: Repaired and tested. Fully operational.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 29 November 2018 Resolved
SOLAS III/7.3 - Immersion suits were al sized XL, sevaerl crew members were provided with suits that were not appropriate size.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2018
Resolved 1 December 2018
Resolution: 20 Universal Adult Immersion Suits purchased and o/b for entire crew.

Ownership record