Records from 2017 to 2025. Most recent: inspection, 17 July 2025.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 18 February 2024
Resolved
... In the case of periodically unattended machinery spaces, fire extinguishing systems shall have both automatic and manual release capabilities. The vessel was operating as a PUMS. During testing of smoke and flame detectors for water mist system over fuel oil purifiers, PSCO observed a failure of the detectors to activate. -74 SOLAS (20) II-2/10.5.6.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 July 2025
Resolution: Faulty sensor(s) were replaced.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 15 February 2024
Resolved
The oil record book part one shall be completed on each occasion on a tank to tank basis if appropriate, whenever any of the following machinery space operation takes place in the ship ... collection and disposal of oil residues (SLUDGE). PSCO discovered 03 25 Liter drums full of sludge in the steering room space. Crew claims it was transfered from the purifier space with no corresponding entry in the Oil Record Book. Additionally the PSCO discovered discrepancies between tank sounding logs and required weekly sludge in oil record book which crew attributes to unrecorded transfers between tanks.
MARPOL Annex I/17.2.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 February 2024
Resolution: Class provided a report saying that the crew has undergone training and is now in compliance with the regulation. See attached Class Survey.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 15 February 2024
Resolved
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency...During 02 consecutive tests, the emergency generator experienced automatic shut down followed by fuel oil leakage alarms.
74 SOLAS (20) II-1/43.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 February 2024
Resolution: Vessel provided class survey attesting to the repairs of the EDG. The EDG was tested and ran satisfactorily to Class. See attached class report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 February 2024
Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company the operational nature of the deficiency noted below provided objective evidence of a serious failure of the implementation of the ISM Code. An external audit report satisfactory to the OCMI is required.
74SOLAS(20)IX/3.1
ISM CODE 10.1
Condition: Invalid
Action required: 30 - Ship detained
Resolved 18 February 2024
Resolution: ISM Audit was Conducted 15FEB24. Vessel has class survey attesting to the correction of noted deficiencies/non-conformities in the ISM Audit report. Please see attached ISM Audit and Class Survey.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 12 February 2024
Resolved
... In the case of periodically unattended machinery spaces fire extinguishing systems shall have both automatic and manual release capabilities. The vessel was operating as a PUMS During testing of smoke and flame detectors for water mist system over fuel oil purifiers, PSCO observed a failure of the detectors to activate. Crew cannot provide records of maintenance of testing of equipment.
74SOLAS(20)II-2/10.5.6.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 February 2024
Resolution: Vessel has received a Condition of Class to change the space to a Manned Machinery Space. Will get repairs at next US port.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 12 February 2024
Resolved
The oil record book part one shall be completed on each occasion on a tank to tank basis if appropriate, whenever any of the following machinery space operation takes place in the ship ... collection and disposal of oil residues (SLUDGE). PSCO discovered 03 25 Liter drums full of sludge in the steering room space. Crew claims it was transfered from the purifier space with no corresponding entry in the Oil Record Book. Additionally the PSCO discovered discrepancies between tank sounding logs and required weekly sludge in oil record book which crew attributes to unrecorded transfers between tanks.
MARPOL Annex I/17.2.3
Condition: Invalid
Action required: 30 - Ship detained
Resolved 15 February 2024
Resolution: Deficiency cleared; recommend checking vessel when it returns to US after sailing foreign.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 February 2024
Resolved
il fuel pipes, which, if damaged would allow oil to escape from a storage, settling or daily service tank having a capacity of 500 liters or above. Situated above the bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned of the event in a fire occurring in the space in which such tanks are situated. PSCO observed quick closing valves attached to the HFO holding tank and MGO storage tank blocked open with bolts and wooden wedges.
74SOLAS(20)II-2/4.2.2.3.4
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 15 February 2024
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 February 2024
Resolved
In a ship in which oil is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board and shall at least comply with the following provisions. PSCO observed pools of standing oil in void space forward of the starboard HFO holding tank.
74SOLAS(20)II-2/4.2.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 15 February 2024
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 12 February 2024
Resolved
Control exercise by a dually authorized control officer under article X shall be limited to the following; assessment, in accordance with section A-I/4 of the STCW Code, of the ability of the seafarers of the ship to maintain watchkeeping and security standards, as appropriate, as required by the Convention if there are clear grounds for believing that such standards are not being maintained because any of the following have occurred; the ship is otherwise being operated in such a manner as to pose a danger to persons, property, the environment, or a compromise security. PSCO observed bolts on the quick closing valves rendering them blocked in opened position. Fire detection systems were not being maintained in accordance with the manufacture instructions.
STCW I/4.1.3.3.4
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 15 February 2024
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 February 2024
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. Means shall be provided to control leaks of flammable liquids. Flag State Inspection conducted on 11Feb2024 identified, "excessive oil leaks at incinerator tank, all three auxiliary engines, purifier room, and steering gear room."
74 SOLAS (14 Cons.) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 February 2024
Resolved
Fixed fire detection and fire alarm systems installation shall be suitable for the nature of the space, fire growth potential and potential generation of smoke and gases. Smoke detector at engine control room does not work. Ship has no extension stick for checking detectors. Using brush handle.
74 SOLAS (14 Cons.) II-2/7.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 February 2024
Resolved
Electrical installations shall be such that all electrical and auxiliary services necessary for maintaining the ship in normal operational and habitable conditions will be ensured without recourse to the emergency source of electrical power. Electric panel at engine room doors wide opened and ventilated with aftermarket fan.
74 SOLAS (14 Cons.) II-1/40.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 February 2024
Resolved
Electrical or other equipment which may constitute a source of ignition of clammable vapours shall not be permitted in these compartments except as permitted in paragraph 10. No electrical equipment shall be installed in any space where flammable mixtures are liable to collect, e.g in compartments assigned principally to accumulator batteries. PSCDO observed excessive amount of old batteries stored in the emergency generator space behind the switchboard.
74 SOLAS (20) I-1/45.9.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2024
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall eb installed and protected as to reduce to a minimum any danger to the persons on board. Flag State Inspection conducted on 11Feb2024 identified, "massive water leak mixed with oil next to low sea chest."
74 SOLAS (14 Cons.) II-2/26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2024
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 12 February 2024
Resolved
This part prescribes regulations governing the design and construction of marine sanitation devices under section 312 of the Federal Water Pollution Control Act (33 USC 1322), to eliminate the discharge of untreated sewage from vessels into the waters of the United States, including territorial seas. Vessel's Marine Sanitation Device is inoperable and has been for over a year. Vessel has a flexible hose transfer arrangement from the on deck sewage discharge flange into a flexible hose that is secured along side accommodation superstructure that hose assembly empties in the Aft Peak Tank Vent (vessel removed tank vent/ flame screen). Aft Peak Tank is being utilized as a Type III holding tank for sewage not designed to contain H2S.
33 CFR 159.1
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 October 2023
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO SHIP OR PERSONS ON BOARD. VESSEL IS EXPERIENCING FUEL INJECTOR ISSUES ON MAIN ENGINE AS A RESULT OF FUEL CHANGE OVER. VESSEL CURRENTLY CAN ONLY MAKE 8 KTS.
74 SOLAS (20) I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2023
Resolution: Class report attested to repairs of service representative and crew of replacing a gasket, reconditioning five fuel injectors and replacing one fuel injector to perform satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 October 2023
Resolved
THE MACHINERY BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSYTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. PSCO OBSERVED ACTIVE COOLING WATER LEAK ON M/E CYLINDER #6.
74 SOLAS (20) II-1/26
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2023
Resolution: Class report attested to repairs by crew disassembling and renewed faulty parts.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 13 October 2023
Resolved
ANY FAILURE OF THE OIL FILTERING EQUIPMENT SHALL BE RECORDED IN THE ORB PART 1. VESSEL WAS ISSUED FLAG DISPENSATION FOR MALFUNCTIONING OWS ON SEPT 22, 2023 WITH NO DOCUMENTATION IN ORB PART 1.
MARPOL 1/17.5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2023
Resolution: CORRECTED ON THE SPOT.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 October 2023
Resolved
THE MACHINERY BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSYTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. SEA WATER INLET WAS FOUND WITH SOFT PATCH AND NO APPROVED DOCUMENTATION.
74 SOLAS (20) II-1/26.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2023
Resolved 18 October 2023
Resolution: BV issued a Condition of Class. Spare parts for seawater flange were not able to be acquired.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 October 2023
Resolved
IN SHIPS WHERE FUEL OIL IS USED...OIL SOAKED LAGGING WAS FOUND THROUGHOUT ENGINE ROOM, SPECIFICALLY IN OIL PURIFIER ROOM. GENERATORS AND BOTTOM DECK ENGINE ROOM.
74 SOLAS (20) II-2/4.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 18 October 2023
Resolution: Class report attested to actions of crew cleaning and replacing lagging throughout machinery space.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 13 October 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2023
Resolution: CORRECTED ON THE SPOT.