MAURY USCG vessel records
← All vessels

IOLCOS VISION

IOLCOS VISION is a 2010 freight ship. The Coast Guard has recorded 5 inspections since 2017, most recently in November 2019, along with 3 deficiencies — 1 with no resolution recorded —.

Records from 2017 to 2019. Most recent: inspection, 11 November 2019.

Built
2010
Last inspected
11 November 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 November 2019
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2017–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9425148
9HA2091
1102732
Flag
MALTA
Maury page id
psix-1102732

Documentation record

Tonnage as PSIX records it89732 - Dead Weight, Ton
104441 - Displacement, Ton
27675 - Convention (Subpart B), Net Ton
47984 - Simplified, Gross Ton
27675 - Simplified, Net Ton
47984 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

11 November 2019 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6853375
17 February 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6627155
8 February 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6612871
25 September 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6539605
13 December 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6318820

Deficiency record · 3

10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 11 November 2019 No resolution recorded
74SOLAS(14; V/23.2.1: All arrangements used for pilot transfer shall efficiently fulfill their purpose of enabling pilots to embark and disembark safely. The appliances shall be kept clean and properly maintained. PSCO observed side ropes on both unloaded condition ladders are dry rotted and brittle to the touch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2019 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 February 2019 Resolved
07199 - Other (fire safety)- The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respect will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed fuel samples stowed in ssteering gear room. Provide clarification from class for proper stowage of fuel samples. 74 SOLAS (2014 Cons.) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2019
Resolved 13 February 2019
Resolution: PSC NOLA received a class report from LR satisfying the requirement.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 13 December 2017 Resolved
FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. EMERGENCY FIRE PUMP WAS INOPERABLE. CITE: SOLAS 14 II-2/14.2.1.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2017
Resolved 14 December 2017
Resolution: On Thursday, December 14, 2017 at 2148, received class report rectifying emergency fire pump deficiency. Class report attached in documents.

Ownership record