Records from 2019 to 2024. Most recent: inspection, 14 July 2024.
Inspection history · 11
14 July 2024
Explosive Handling Operation-Commercial
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7958828
21 February 2024
Explosive Handling Operation-Administrative
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7868444
17 October 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7809886
7 October 2023
PSC A
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7804611
23 March 2023
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7655254
20 March 2023
Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7653904
16 July 2022
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7506648
9 September 2021
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7308661
17 February 2021
PSC A
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7141459
24 March 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6930981
6 May 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6677902
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 October 2023
Resolved
Means shall be provided to limit the accumulation o flammable vapors.
PSCO observed oiled overhead in fuel oil purifier room, including fire detectors, fixed fire extinguishing nozzles and overhead piping above #4 oil purifier. Additionally, a small open bucket of oil was found in an open space adjacent to the generator space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2023
Resolved 17 October 2023
Resolution: Vessel master submitted photo evidence of satisfactory cleaning done to oiled surfaces.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 February 2021
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA. PSCO OBSERVED LEAK ON SACRIFICIAL FLANGE ON NO. 1 CENTRAL F/W COOLER. 74SOLAS(14)I/11.a 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2021
Resolution: Sacrificial Flange replaced, filter cleaned, pipe welded. See attached document
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 February 2021
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA. PSCO OBSERVED OIL LEAK ON NO.2 LUBE OIL COOLER. 74SOLAS(14)I/11.a 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 February 2021
Resolution: Bolts tightened to compress cooler plates. See attached document
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2019
Resolved
74SOLAS(14)II-2/4.1.3 17 ac PURPOSE OF THIS REGULATION IS TO PREVENT OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: THE IGNITABILITY OF COMBUSTIBLE MATERIALS SHALL BE RESTRICTED. PSCO OBSERVED OIL SOAKED LAGGING THROUGHOUT THE OIL PURIFIER ROOM.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2019
Resolution: Recieved class report attesting to the replacement of the lagging.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2019
Resolved
74SOLAS(14)II-2/4.1.1 17 ac PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED FUEL LEAKS ON MAIN ENGINE CYLINDERS NUMBER 2, 9, AND 12.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2019
Resolution: Recieved class report attesting to the repair of the fuel leaks.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 May 2019
Resolved
74SOLAS(14)II-2/9.4.2.1 10c DOORS FITTED IN BOUNDARY BULKHEADS OF MACHINERY SPACES OF CATERGORY A SHALL BE REASONABLY GASTIGHT AND SELF-CLOSING. PSCO OBSERVED CLASS "A" DOOR IN FORWARD END OF WORKSHOP LEADING TO OPEN SPACE ENGINE ROOM TO BE NON SELF-CLOSING DUE TO BROKEN HANDLE.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 6 May 2019
Resolution: VESSEL'S CREW FIXED DOOR HANDLE AND ADJUSTED SELF-CLOSING MECHANISM FOR PROPER OPERATION.