MAURY USCG vessel records Sign in
← All vessels

E. R. BAYONNE

E. R. BAYONNE is a freight ship. The Coast Guard has recorded 2 inspections since 2012, most recently in January 2017, along with 1 deficiency.

Records from 2012 to 2017. Most recent: inspection, 3 January 2017.

Built
Not recorded
Last inspected
3 January 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9507520 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1102809
Flag
LIBERIA
—
Maury page id
psix-1102809

Inspections, by type

Years with a record 2 calendar years (2012–2017)
The 2 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it93186 - Convention (Subpart B), Gross Ton
59500 - Convention (Subpart B), Net Ton
205492 - Displacement, Ton
178978 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 2

3 January 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6063102
3 January 2012 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4217353

Deficiency record · 1

Fire Fighting › Self-contained Breathing Apparatus › Facepiece
Issued 3 January 2012 Resolved
0735 - Personal equipment fire-fighting - Vessel shall have two fire fighting outfits that comply with the FSS Code. Vessels fire fighting breathing apparatus shall be self contained and capable of functioning for at least 30 minutes. The mask for the second fire fighting SCBA is broken and unusable. SOLAS 09 Cons. CH II - 2 Reg 10.1 FSS CODE CH 3 Reg 2.1.2
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2012
Resolution: Received receipt from the vessel''s agent providing proof that the vessel purchased a new portable SCBA. 01 deficiencies cleared and 00 deficiency remains outstanding.

Ownership record