THRUSH is a freight ship. The Coast Guard has recorded 6 inspections since 2016, most recently in June 2018, along with 5 deficiencies and 2 operational controls, 1 with no removal date recorded.
Records from 2016 to 2018. Most recent: inspection, 21 June 2018.
This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it18571 - Convention (Subpart B), Net Ton 53297 - Dead Weight, Metric Ton 63708 - Displacement, Metric Ton 31241 - Regulatory (Subpart C or D), Gross Ton 18571 - Regulatory (Subpart C or D), Net Ton 31241 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 6
21 June 2018Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6451511
1420 - Cleanliness of engine room - Means shall be provided to provide control of flammable liquids. PSCO observed F/O leak IWO: #1,#3 SSG fuel pump casing and F/O inlets, #1,#2#4 MDE F/O supply valves, SSG F/O line in purfier room, MDE F/O drain lines oil soaked lagging, #3 F/O pump inop. 74 SOLAS (2009) II-2/4.1 60a.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 12 September 2017
Resolved 19 September 2017
Resolution: Received class report from NKK stating all F/O leaks had been repaired, oil soaked lagging renewed, and reed switch on #3 SSG has been renewed and is operational.
1499 - Other (Prop. & Aux. Machinery) - Boiler shall be provided with means to supervise and control quality of feedwater. Suitable arrangements shall be provided to preclude the entry of oil. PSCO observed an oily substance and other contaminants inside the cascade tank. 74 SOLAS (2004) II-1/32.5 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2017
Resolved 19 September 2017
Resolution: Received class report from NKK stating cascade tank was drained, cleaned and re-charged.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 12 September 2017Resolved
1499 - Other (Prop. & Aux.Machinery) - Boilers shall be of a design adequate for services which they are intended and shall be installed and protected as to reduce any danger to persons onboard, due regard to hot surfaces and other hazards. PSCO observed pipe repair to boiler feed water line and lagging was not replaced. 74 SOLAS (2004) II-1/26.1 16a
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 September 2017
Resolved 19 September 2017
Resolution: Received class report from NKK stating lagging has been re-fitted.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 29 August 2016Resolved
74 SOLAS 14 II-2/14.2.1.1.1 0799
PSCO OBSERVED 03 CLASS A DOORS THAT WERE NOT SELF CLOSING IN ACCORDANCE WITH THE SHIPS FIRE CONTROL PLAN. DOORS OBSERVED WERE IN THE GALLEY.
Action required: 705 - Other - as specified
Due 12 September 2016
Resolved 30 August 2016
Resolution: Email from vessel
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 29 August 2016Resolved
74 SOLAS 14 II-2/9.2.3.4.1 0799
PSCO OBSERVED 01 DOOR IN B DECK STAIRWAY THAT WAS NOT SELF CLOSING.
Action required: 705 - Other - as specified
Due 12 September 2016
Resolved 29 August 2016
Resolution: Corrected on the Spot
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.