MAURY USCG vessel records
← All vessels

SEA VALIANT

SEA VALIANT is a 2010 tank ship. The Coast Guard has recorded 8 inspections since 2022, most recently in May 2025, along with 2 deficiencies and 1 operational control.

Records from 2022 to 2025. Most recent: operational control imposed, 9 May 2025.

Built
2010
Last inspected
9 May 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 May 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2022–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9420629
V7A5252
1103009
Flag
MARSHALL ISLANDS
Maury page id
psix-1103009

Documentation record

Tonnage as PSIX records it60379 - Convention (Subpart B), Gross Ton
32114 - Convention (Subpart B), Net Ton
99998 - Dead Weight, Metric Ton
118034 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

9 May 2025 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8132008
29 April 2025 PSC B · COC-TVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8119818
26 April 2024 PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7901604
15 December 2023 COE-Administrative
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7839476
21 November 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7828441
9 May 2023 Administrative Inspection · COC-TVE Annual · PSC B · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7684807
1 September 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7548756
4 April 2022 PSC B · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7422657

Deficiency record · 2

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2025 Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those accceptable to the organization. Insulation removed on lighting cables and associated bonding straps on numerous lighting fixtures within the cargo pump room. SOLAS (2020) II-1/45.11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2025
Resolution: Received class report from Lloyds. Damaged portion of cables were cut off and reinstalled on lighting fixture. Class report uploaded to deficiency documents.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 May 2023 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. PSCO observed 01 broken smoke detector held in place with tape, on the 02 deck of the cargo pump room. Crew replaced with new detector but were unable to satisfactorily test it.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2023
Resolution: Repairs made. Class report received.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.