Records from 2016 to 2026. Most recent: inspection, 14 May 2026.
Inspection history · 23
14 May 2026
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8375511
21 January 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8299186
9 June 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8156210
13 May 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8135092
29 April 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8127318
31 May 2024
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7926859
14 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7912191
17 May 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7690677
26 April 2023
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7676766
19 May 2022
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7454965
10 May 2021
COI Inspection · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7128176
30 April 2021
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7191709
6 October 2020
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7072697
10 August 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7037872
14 May 2019
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6718899
29 April 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6674468
14 June 2018
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6444327
16 May 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6420973
19 August 2017
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6250472
17 May 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6152921
2 May 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6139737
26 April 2017
DAPI Audit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6136415
9 May 2016
COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5835962
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2026
No resolution recorded
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned space. High water alarm in engine compartment does not alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2026
No resolution recorded
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child size life jackets were stowed with adult life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 May 2025
Resolved
46 CFR 180.205(e)(3)
Each vessel certificated to operate on a limited coastwise route within three miles from land in warm water must have on board a FCC type accepted category 1 406 MHz EPIRB, installed to automatically float free and activate, and not be required to carry survival craft.
- Vessel's EPIRB battery and hydrostatic release were expired. Vessel is restricted to LBS route within 1 mile from shore (cold water)until repaired.
Action required: 705 - Other - as specified
Resolved 9 June 2025
Resolution: Recieved pictures via email confirmining the replacement of new batteries for the EPIRB.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2025
Resolved
46 CFR 182.520(e)
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a).
- Vessel's engine room bilge pump was non operational
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2025
Resolution: Repairs have been made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 May 2025
Resolved
46 CFR 182.530(a)
On a vessel of at least 26ft in length, a visual and audible alarm must be provided at the operating station.
- Engine room bilge alarm was non-operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2025
Resolution: Repairs have been made.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 May 2024
Resolved
01305 - Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The vessel did not have any abandon ship or man overboard drill records.
46 CFR 185.520(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2024
Resolution: Received a copy of drill logs via email.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 May 2024
Resolved
01305 - Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The vessel did not have any firefighting drill records.
46 CFR 185.524(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2024
Resolution: Received a copy of drill logs via email.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 May 2024
Resolved
01305 - The master of the vessel shall ensure that: each EPIRB must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. The vessel did not have any EPIRB test records.
46 CFR 185.728(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2024
Resolution: Received a copy of test logs via email.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 May 2024
Resolved
18299 - Alcohol testing must be conducted on each individual engaged or employed on board the vessel who is directly involved in the SMI within 2 hours of when the SMI occurred. Alcohol-testing devices must be used according to the procedures specified by the manufacturer of the testing device and by this part. There were not alcohol testing devices on board the vessel.
46 CFR 4.06-3(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: Vessel obtained new alcohol swabs.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 May 2022
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: (1) A light to indicate discharge; (2) An audible alarm that sounds upon discharge; and (3) A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section.
Vessel pre-engineered fixed gas fire extinguishing system did not alarm audibly when tested.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 May 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 May 2021
Resolved
Repair inoperative bilge pump visual indicator (light) for forward compt bilge pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2023
Resolution: Verified compliant during second annual inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 10 May 2021
Resolved
Provide valid FCC Safety Radio Telephoney Certificate. Vessel restricted to operations NMT 1000 FT from shore until provided.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 May 2023
Resolution: Verified compliant during second annual inspection.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 May 2021
Resolved
Renew expired EPIRB registration.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2023
Resolution: Verified compliant during second annual inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 August 2020
Resolved
Provide current/valid Certificate of Documentation.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2020
Resolved 6 October 2020
Resolution: Owner applied for renewal COD.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 14 May 2019
Resolved
Repair inop forward bilge alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2019
Resolved
Prove proper operation of forward & aft bilge pump float switches.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2019
Resolved
Replace flame impingement bowl on fuel filter housing in engine compt.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2019
Resolved
Renew or repair deteriorated life ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2019
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 May 2018
Resolved
Repair inoperative bilge pump operation light/indicator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2018
Resolved 17 May 2018
Resolution: Repaired.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 16 May 2018
Resolved
Prove proper operation of FGFE system, including engine shutdown feature.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2018
Resolved 17 May 2018
Resolution: Demonstrated operation.
Engineering › Bilge Water Management System › Piping
Issued 9 May 2016
Resolved
Renew holed bilge discharge hose in forward compartment.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 24 May 2016
Resolution: Renewed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 May 2016
Resolved
Repair/Renew aft bilge alarm.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2016
Resolved 24 May 2016
Resolution: Renewed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 May 2016
Resolved
Repair automatic bilge pump visual indicator lights on switch board.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 17 May 2017
Stability › Watertight Integrity › General
Issued 9 May 2016
Resolved
Repair broken forward anchor hatch dogs to allow weathertight closure.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 17 May 2017
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 May 2016
Resolved
Provide valid COD. COD applied for, and being mailed at time of inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 1 June 2016
Resolution: Provided.