RIBERA DEL DUERO KNUTSEN is a tank ship. The Coast Guard has recorded 17 inspections since 2016, most recently in February 2026, along with 8 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 16 February 2026.
- Built
- Not recorded
- Last inspected
- 16 February 2026
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
…with no type recorded3
Years with a record
10 calendar years (2016–2026)
The 17 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it96739 - Dead Weight, Metric Ton
131566 - Displacement, Metric Ton
36112 - Convention (Subpart B), Net Ton
111109 - Convention (Subpart B), Gross Ton
131566 - Displacement, Metric Ton
36112 - Convention (Subpart B), Net Ton
111109 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 17
16 February 2026
PSC B · COC-GAS Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8307687
14 November 2024
Deficiency Check · COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8033189
9 November 2023
Deficiency Check · Ballast Water Examination · COC-GAS Annual · PSC B
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7819418
16 October 2022
COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7575337
11 March 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7410137
16 December 2021
PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7367166
6 October 2020
PSC B · COC-GAS Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7070084
6 October 2020
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7072772
25 September 2019
Ballast Water Examination · ISPS II Exam · Deficiency Check · COC-GAS Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6818881
28 August 2019
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6797447
6 September 2018
COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6520680
20 October 2017
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6291869
13 September 2017
Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6264448
13 September 2017
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6326097
18 February 2017
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6091723
12 February 2017
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6086775
2 September 2016
ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5986412
Deficiency record · 8
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 November 2024
Resolved
8.2.6 In the case of cargo tanks permitted to have more than one relief valvesetting this may be accomplished by:.1 installing two or more properly set and sealed valves and providingmeans as necessary for isolating the valves not in use from thecargo tank; or.2 installing relief valves whose settings may be changed by theinsertion of previously approved spacer pieces or alternativesprings or by other similar means not requiring pressure testing toverify the new set pressure. All other valve adjustments should besealed
74 SOLAS VII/13 IGC 8.2.6.2
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 9 November 2023
Resolved
03102 - Freeboard Markings - The ring, lines, and letters shall be painted in white or yellow on a dark ground or in black on a light ground. The marks shall be plainly visible. PSCOs noted load line markings were not plainly visible.
ICLL 66, prg 8
15ac
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 October 2020
Resolved
Vessel has gas fuel pipe ducting that terminates in the gas valve ventilation hood rooms. PSCO observed 3mbar of pressure in the ventilation hoof room. The vessel is not maintaining pressure less than atmospheric in the ventilation hood rooms.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 October 2020
Resolved
Vessels crew was unable to demonstrate automatic closing of the Master [name withheld] (MGV) upon both simulated loss of pressure or set point manipulation. The MGV must close upon loss of required air flow.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 25 September 2019
Resolved
Doors on cargo deck which access machinery room not water tights. See Form B.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 25 September 2019
Resolved
No procedures onboard for testing OWS. See form B.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 September 2019
Resolved
Excessive flammable liquid oil and rags in 4 engine generators. See form B.
Fire Fighting › Automatic Sprinkler System › Piping
Issued 13 September 2017
Resolved
On ships carrying flammable or toxic products or both, a water spray system for cooling, fire prvention and crew protection should be installed to cover exposed cargo tank domes and any exposed parts of cargo tanks. The Deck Water Spray does not provide coverage to the #1 cargo vapor dome.