Records from 2010 to 2026. Most recent: inspection, 24 February 2026.
Documentation record
Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2011
Hull materialFRP (Fiberglass)
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
24 February 2026
Internal Structural Exam · Drydock Exam · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8309468
20 January 2026
Annual Inspection · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8299592
24 February 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8084049
29 August 2024
Administrative Inspection · Special
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7992214
5 June 2024
Special Consideration · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7927717
22 February 2024
Administrative Inspection · Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7868276
22 January 2024
Special · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7852890
27 February 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7643197
14 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7411590
9 March 2022
COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7403872
22 April 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7181240
5 May 2020
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6938833
7 April 2020
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6933125
12 March 2019
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6641760
19 October 2018
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570660
8 May 2018
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6404160
24 April 2018
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6395551
20 April 2017
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6123846
21 March 2017
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6107826
24 October 2016
Administrative Inspection · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6028229
3 February 2016
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5826504
1 May 2014
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4852490
17 February 2011
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3984565
26 November 2010
Construction Oversight · Initial Certification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3898919
Communications › Alarms/Indicators › High Water Alarm
Issued 1 May 2014
Resolved
The high water alarm/pump in the E/R is inoperable, repair/replace prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2014
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 May 2014
Resolved
O/O to provide proof of enrollment in the companies consortium.
Action required: 705 - Other - as specified
Due 1 June 2014
Resolved 6 May 2014
Communications › Radio Communications › EPIRB
Issued 1 May 2014
Resolved
Replace the expired EPIRB hydrostatic release, route limited to less than 3nm from shore until the hydrostatic release is replaced.
Action required: 705 - Other - as specified
Resolved 15 May 2014
Resolution: Vessel satisfactory complied with requirement.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 February 2011
Resolved
Provide machinery guard for engine room (around drive shaft).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2011
Documentation › Certificates/Documents › FCC SSL
Issued 26 November 2010
Resolved
Provide FCC SSL, Radio Safety and MROP.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Navigation › Piloting/Steering › Marine Charts
Issued 26 November 2010
Resolved
Provide Nav Pubs
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Communications › Audible Communications › Horn/Whistle
Issued 26 November 2010
Resolved
Provide SPD
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Lifesaving › Hand Flares › Not on Board
Issued 26 November 2010
Resolved
Provide VDS
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 November 2010
Resolved
Conduct Machinery Op Test & New to Zone Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Communications › Radio Communications › EPIRB
Issued 26 November 2010
Resolved
Provide EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 November 2010
Resolved
Provide first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2011
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 26 November 2010
Resolved
Provide portable lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 26 November 2010
Resolved
Provide anchor nad mooring lines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 26 November 2010
Resolved
Provide PFD's
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Lifesaving › Lifebuoys › Not on Board
Issued 26 November 2010
Resolved
Provide Ring Buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Fire Fighting › Fire Bucket › Availability
Issued 26 November 2010
Resolved
Provide Fire Buckets
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Engineering › Bilge Water Management System › Pump
Issued 26 November 2010
Resolved
Provide portable bilge pump
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 November 2010
Resolved
Conduct drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011