Records from 1991 to 2020. Most recent: inspection, 25 November 2020.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 47
25 November 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7102147
25 April 2017
COI Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6128971
23 November 2015
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5768688
5 August 2015
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5212173
17 June 2014
Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4888044
1 May 2014
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4865226
8 May 2012
COI Inspection · Drydock Extension
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4304922
25 August 2011
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4126223
15 August 2008
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3291621
16 July 2008
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3264191
16 July 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2996916
29 June 2006
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2695595
19 July 2005
Deficiency Check · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2374854
9 September 2004
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2191519
19 July 2004
Internal Structural Exam · Hull Examination · Deficiency Check · Plan Review "T" Boat · Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2138314
12 July 2004
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2130508
23 June 2004
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2108008
22 May 2003
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1793485
10 October 2002
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1688146
30 September 2002
Administrative Inspection · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1682028
14 February 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1486619
23 April 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1393660
26 September 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 822540
20 September 2000
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1053900
17 July 2000
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1373109
22 June 2000
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 818942
24 April 2000
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1395459
17 September 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1402948
4 May 1999
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1365226
25 June 1998
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1470163
24 April 1998
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1383857
26 April 1997
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1380847
26 June 1996
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1367810
18 April 1996
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1355747
28 April 1995
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1363263
2 March 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 93664
6 July 1994
Hull Examination · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1172618
23 May 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1394122
22 April 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1167433
3 December 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1158069
13 April 1993
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1144595
5 March 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1144267
23 November 1992
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 827006
14 May 1992
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 958464
14 April 1992
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1267667
24 March 1992
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1256386
24 April 1991
Initial Certification · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 929134
Construction/Loadline › Hull › Hull Plating
Issued 26 April 2017
No resolution recorded
Vessel in wet lay-up status, as per "request for lay-up status" dated 05Aug2015, vessel required hull exams prior to placing back in service. 46CFR176.600
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Drug and Alcohol Testing › CG Notification (positive results/refusals)
Issued 26 April 2017
No resolution recorded
Required to undergo drug and alcohol program audit prior to carrying passengers. 46CFR16
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 April 2017
No resolution recorded
Required to conduct drills prior to carrying passengers. 46CFR185.520
Action required: 701 - Prior to carriage of passengers/cargo
Navigation › Collision/Grounding Avoidance › Radar
Issued 26 April 2017
No resolution recorded
Radar inoperable. Restore to operational status. 46CFR184.404
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Bilge Water Management System › Not Operational
Issued 26 April 2017
No resolution recorded
Fixed bilge suction inoperable due to starboard engine being inoperable. Operate bilge suction after starboard engine is fixed. 46 CFR 182.25-10.
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 26 April 2017
No resolution recorded
Starboard main engine inoperable. Restore to operational status. 46 CFR 182.05-1.
Action required: 701 - Prior to carriage of passengers/cargo
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 26 April 2017
No resolution recorded
FCC Safety Radiotelephony Certificate expired. Renew certifiate. 47CFR80.59
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 August 2015
Resolved
Conduct drills and underway operational tests prior to placing the vessel back into service to carry passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 November 2015
Resolution: Witnessed satisfactory underway drills.
Lifesaving › Hand Flares › Expired
Issued 17 June 2014
Resolved
Provide (3) hand orange smoke distress signals.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2014
Resolution: Received confirmation of purchase from operator.
Stability › Watertight Integrity › General
Issued 17 June 2014
Resolved
Provide/install new gasket for hatch to lazarette to make hatch watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2014
Resolution: Received photo from the operator confirming repairs.
Engineering › Bilge Water Management System › Pump
Issued 17 June 2014
Resolved
Provide 5 GPM portable hand pump for the bilge. (Old T 46 CFR 179.360 (a))
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2014
Resolution: Operator provided proof of purchase.
Construction/Loadline › Hull › Hull Plating
Issued 8 May 2012
Resolved
Port shaft tube cracked near hull penetration. CG-835 issued; provide repair proposal, complete repairs to port shaft tube.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2012
Resolution: Affected area was gouged out to good metal, rewelded.
Construction/Loadline › Hull › Bottom Plating
Issued 8 May 2012
Resolved
Isolated pitting caused by corrosion in excess of 25% wastage on wear ring insert for rudder. CG-835 issued to properly repair rudder wear plate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2012
Resolution: Affected area clad welded, inspected sat.
Communications › Audible Communications › Horn/Whistle
Issued 8 September 2011
Resolved
Provide proof of operable horn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2011
Resolved 20 October 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 August 2011
Resolved
Provide new port running light lens.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2011
Resolved 20 October 2011
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 August 2011
Resolved
Provide updated Coast Pilot [name withheld] and charts for route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2011
Resolved 27 October 2011
Documentation › Markings/Placards › Lifejacket Placard
Issued 25 August 2011
Resolved
Provide donning placard for PFDs on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2011
Resolved 20 October 2011
Navigation › Piloting/Steering › Compass Deviation Table
Issued 25 August 2011
Resolved
Renew compass deviation card.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2011
Resolved 20 October 2011
Lifesaving › Lifefloat › Serviceable
Issued 25 August 2011
Resolved
Re-condition color on 15 person life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2011
Resolved 21 November 2011
Resolution: 15 Person life float''s color was re-conditioned.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 August 2011
Resolved
Remove open-ended wires on aft bulkhead battery connection and distribution box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2011
Resolved 20 October 2011
Construction/Loadline › Penetrations › Gasket
Issued 25 August 2011
Resolved
Provide new gaskets on 3 engine room hatches to make weather tight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2011
Resolved 20 October 2011
Fire Fighting › Fire Hoses › Connections
Issued 25 August 2011
Resolved
Renew gasket on fire hose deck valve connection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2011
Resolved 20 October 2011
Engineering › Lubricating Oil Service System › Piping
Issued 25 August 2011
Resolved
Replace main hydraulic supply hoses to comply with J1942 standard on port and starboard reduction gears.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2011
Resolved 20 October 2011
Accommodation/Occupational Safety › Washroom/Toilet › Location
Issued 25 August 2011
Resolved
Repair/replace handle assembly for the head.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2011
Resolved 20 October 2011
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 August 2008
Resolved
Repair engine room + aft steering bilge alarms.
Due 15 September 2008
Resolved 19 September 2008
Resolution: Proved proper operation of engine and aft steering bilge alarms.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 19 July 2005
Resolved
Service all expired portable fire extinguishers. COS 7/19/05.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 August 2005
Resolved 19 July 2005
Lifesaving › Lifefloat › Float Free
Issued 19 July 2005
Resolved
Remove all unnecessary equipment (i.e. line, mops) stored in 15-person lifefloat. COS 7/19/05.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2005
Resolved 19 July 2005
Lifesaving › Lifefloat › Paddle
Issued 19 July 2005
Resolved
Secure paddles to 15 person lifefloat. COS 7/15/05.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2005
Resolved 19 July 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 July 2005
Resolved
Renew all expired items in the first aid kit. COS 7/15/05.
Due 19 July 2005
Resolved 19 July 2005
Engineering › Steering Gear System › Chain
Issued 19 July 2005
Resolved
Permanently mount steering linkage guide to prevent chaffing of steering linkage. COS 7/19/05.
Due 19 July 2005
Resolved 19 July 2005
Construction/Loadline › Hull › Hull Plating
Issued 19 July 2004
Resolved
Provide repair proposal for approval to crop and renew starboard side of hull adjacent to #2void space (1 sq ft area chalked/ 2 one inch diameter pits found, 3 pinhole size pits found in adjacent welds)
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2004
Resolved 20 July 2004
Resolution: Repaired sat.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 22 June 2004
Resolved
Install locking mechanism for sewage ovbd valve.
Due 22 July 2004
Resolved 19 July 2004
Resolution: Installed.
Stability › Watertight Integrity › General
Issued 22 June 2004
Resolved
Tighten stuffing tube packing for lazarette bilge high level alarm wire on aft engine room blkhd.
Due 22 July 2004
Resolved 19 July 2004
Resolution: Tightened sat.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 22 June 2004
Resolved
Adjust support bracket for stbd emergency fuel shut off valve handle to allow valve to fully close.
Due 22 July 2004
Resolved 19 July 2004
Resolution: Adjusted sat.
Electrical › Electric Supply System (service) › Cable
Issued 22 June 2004
Resolved
Provide plans to replace existing welding cables from starting batteries to port and stbd main engine starters with marine grade battery cable. Upon approval renew.
Due 22 July 2004
Resolved 19 July 2004
Resolution: Provided.
Communications › Radio Communications › VHF Radiotelephone
Issued 22 June 2004
Resolved
Label emergency broadcast placard where old labeling has faded.
Due 22 June 2004
Resolved 22 June 2004
Resolution: Corrected on spot.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 June 2004
Resolved
Renew retroreflective material on lifering.
Due 22 June 2004
Resolved 22 June 2004
Resolution: Corrected on spot.
Stability › Watertight Integrity
Issued 30 September 2002
Resolved
Provide watertight dogs for engine room hatches for vsl not operating in protected waters. LEGACY COMPONENT DESC: Engine room hatch
Due 30 November 2002
Resolved 7 October 2002
Resolution: Dogs installed on engine room hatches.
Stability › Weathertight Integrity
Issued 30 September 2002
Resolved
Provide 6" combing for weathertight door accessing passenger cabin. LEGACY COMPONENT DESC: Passenger Cabin Door
Due 30 November 2002
Resolved 7 October 2002
Resolution: 6 inch high coaming installed at access to passenger compartment.
Construction/Loadline
Issued 4 May 1999
Resolved
Provide hose on portable bilge pump that is long enough to reach the bottomof all compartments.
Condition: Unknown
Due 31 May 1999
Resolved 26 May 1999
Construction/Loadline
Issued 4 May 1999
Resolved
Provide visual alarm at operating station for high bilge level alarms.
Condition: Unknown
Due 31 May 1999
Resolved 26 May 1999
Construction/Loadline
Issued 4 May 1999
Resolved
Provide bilge foot in forepeak with strainer that is 3X area of bilge pipe.
Condition: Unknown
Due 31 May 1999
Resolved 26 May 1999
Engineering
Issued 4 May 1999
Resolved
Ensure proper operation of starboard fuel shutoff valve.
Condition: Unknown
Due 31 May 1999
Resolved 26 May 1999
Navigation
Issued 4 May 1999
Resolved
Provide updated chart of operating area.
Condition: Unknown
Due 31 May 1999
Resolved 26 May 1999
Construction/Loadline
Issued 4 May 1999
Resolved
Attach captive device to forepeak hatch.
Condition: Unknown
Due 31 May 1999
Resolved 26 May 1999
Construction/Loadline
Issued 26 April 1997
Resolved
Repair crack in starboard bow ensuring proper preparation and weld procedures are used.
Condition: Unknown
Due 26 April 1997
Resolved 26 April 1997
Documentation
Issued 22 April 1994
Resolved
PROVIDE UPDATED/CORRECTED COAST PILOT OF LOCAL OPERATING AREA.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Electrical
Issued 22 April 1994
Resolved
MAKE ALL WIRE RUNS THROUGH FORWARD E/R BULKHEAD WATERTIGHT.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Unknown
Issued 22 April 1994
Resolved
PROVIDE PARTITION BETWEEN ADULT AND CHILD PFD'S STOWAGE COMPARTMENTS.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Accommodation/Occupational Safety
Issued 22 April 1994
Resolved
PROVIDE MEANS OF SECURING OVERBOARD DISCHARGE VALVE FOR MARINE SANITATION DEVICE.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Construction/Loadline
Issued 22 April 1994
Resolved
RAISE ALL BILGE STRAINERS ATLEAST 1" FROM DECK.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Accommodation/Occupational Safety
Issued 13 April 1993
Resolved
INSTALL MEANS OF SECURING MARINE SANITATION DEVICE OVERBOARD DISCHARGE VALVE.
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Engineering
Issued 13 April 1993
Resolved
REPAIR 2 CRACKED WELDS ADJACENT TO INBOARD, AFT PORT ENGINE MOUNT.
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Electrical
Issued 13 April 1993
Resolved
CAP OR REMOVE THE WIRES LEFT ON BOARD FROM WHEN THE GENERATOR WAS REMOVED.
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Construction/Loadline
Issued 13 April 1993
Resolved
LABEL ALL VALVES ON BILGE MANIFOLD.
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Fire Fighting
Issued 14 April 1992
Resolved
PROVIDE HAND FIRE/BILGE PUMP.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Engineering
Issued 14 April 1992
Resolved
PROVIDE LAGGING FOR STARBOARD ENGINE EXHAUST PIPING.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992