VALENCIA KNUTSEN is a 2010 tank ship. The Coast Guard has recorded 12 inspections since 2016, most recently in July 2024, along with 5 deficiencies and 2 operational controls.
Records from 2016 to 2024. Most recent: inspection, 29 July 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it110920 - Regulatory (Subpart C or D), Gross Ton 34573 - Regulatory (Subpart C or D), Net Ton 110920 - Convention (Subpart B), Gross Ton 34573 - Convention (Subpart B), Net Ton 97793 - Dead Weight, Ton 131724 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 12
29 July 2024PSC B · Deficiency Check · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7964027
7 February 2022Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7391750
16 January 2022Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7382158
6 August 2021COC-GAS Renew · Deficiency Check · PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7269743
9 April 2020COC-GAS Renew
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6936004
7 April 2020Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6935398
21 July 2017Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6216399
19 July 2017ISPS II Exam · COC-GAS Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6207635
17 July 2017Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6209239
26 May 2016Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5887062
24 May 2016COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5881057
24 May 2016Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6093271
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 29 July 2024Resolved
EACH CARGO TANK SHOULD BE FITTED WITH A HIGH LIQUID LEVEL ALARM OPERATING INDEPENDENTLY OF OTHER LIQUID LEVEL INDICATORS AND GIVING AN AUDIBLE AND VISUAL WARNING WHEN ACTIVATED.
DURING TESTING OF TANK LEVEL ALARMS, PSCO OBSERVED THE #4 CARGO TANK HIGH LEVEL ALARM WAS MALFUNCTIONING AND COULD NOT BE RESET. VESSEL TO RECTIFY ALARM PRIOR TO LOADING CARGO.
74SOLAS(20)VII/13.1
IGC CODE(93)/13.3.1
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2024
Resolved 30 July 2024
Resolution: Received report from DNV surveyor attesting to satisfactory repair and operational test of the #4 cargo tank high level alarm.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 29 July 2024Resolved
ON SHIPS CARRYING FLAMMABLE OR TOXIC PRODUCTS OR BOTH, A WATER-SPRAY SYSTEM FOR COOLING, FIRE PREVENTION AND CREW PROTECTION SHOULD BE INSTALLED TO COVER: BOUNDARIES OF SUPERSTRUCTURES, CARGO COMPRESSOR ROOMS, CARGO PUMP ROOMS.
PSCO OBSERVED A SIGNIFICANT AMOUNT OF DECK WATER SPRAY NOZZLES ON THE SUPERSTRUCTURE, COMPRESSOR ROOM AND MOTOR ROOM THAT WERE CLOGGED AND NOT PROVIDING ADEQUATE COVERAGE.
74SOLAS(20)VII/13.1
IGC CODE(93)/11.3.1.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2024
Resolved 30 July 2024
Resolution: Received report from DNV surveyor attesting to satisfactory repair and operational test of the deck water-spray sytem.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 16 January 2022Resolved
ECDIS- All ships, irrespective of size shall have back-up arrangements to meet the functional requirements of subparagraph .4, if this function is partly or fully fulfilled by electronic means. Vessel is currently operating without a secondary means to the ECDIS.
74 SOLAS (20 cons.) V/19.2.1.5
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 7 February 2022
Resolution: Recieved satisfactory class report from DNV attesting to repair of ECDIS.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 August 2021Resolved
Dry chemical powder systems shall be tested for moisture content every two years.
Vessel was due for their moisture teston on 27JUN21, no test has yet been completed.
74 Solas Cons. 2014 II-2 14.2.2.1
Circ/MSC/01/1432/8.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2021
Resolved 24 August 2021
Resolution: RECORD OF DRY POWDER MOISTURE TEST RECEIVED 08/24/2021
Deck/Cargo › Cargo Condition › Bulk Liquefied Gas
Issued 20 July 2017Resolved
Gas detection equipment should so designed that it may readily be tested. Suitable equipment and span gas for this purpose should be carried on board. Gas detection equipment is unable to be calibrated. System is not able to accurately detect gas concentration levels on board. Vessel is not allowed to conduct cargo ops until rectified. SOLAS (14) VII/13.1. IGC 13.6.6.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2017
Resolution: Vessel replaced two IR sensors with onboard spares. Witnessed satisfactory test of gas detection system.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.