MAURY USCG vessel records
← All vessels

NAVE COSMOS

NAVE COSMOS is a 2010 tank ship. The Coast Guard has recorded 7 inspections since 2016, most recently in June 2025, along with 2 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 19 June 2025.

Built
2010
Last inspected
19 June 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 June 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9457024
9HA2495
1103937
Flag
MALTA
Maury page id
psix-1103937

Documentation record

Tonnage as PSIX records it17846 - Convention (Subpart B), Gross Ton
6796 - Convention (Subpart B), Net Ton
25130 - Dead Weight, Ton
32829 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

19 June 2025 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8162658
10 May 2022 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7445593
10 May 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7447422
20 June 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6981712
30 August 2019 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6798917
12 August 2016 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5970921
24 June 2016 COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5910447

Deficiency record · 2

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 August 2019 Resolved
Associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons onboard. Fresh water generator supply piping approximately one foot after supply valve ruptured. Crew closed supply an discharge valves, but did not stop leak. Crew installed temporary patch. 74SOLAS(14)II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 August 2019
Resolution: Section of pipe was replaced and welds were certified to the satisfaction of Class.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 24 June 2016 Resolved
74 SOLAS (2004 CONS.) II-2/9.3.1. MULTIPLE PENETRATIONS WITHOUT PROPER INSULATION FOUND IN CLASS "A" BULKHEAD ON B DECK PIPE TRUNK AFTER CLASS SURVEY WAS COMPLETED. ACTION TAKEN: 50A/C.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 July 2016
Resolved 12 August 2016
Resolution: Received class report clearing deficiency.

Ownership record