← All vessels
NAVE COSMOS
NAVE COSMOS is a 2010 tank ship. The Coast Guard has recorded 11 inspections since 2010, most recently in June 2025, along with 6 deficiencies and 6 operational controls.
Records from 2010 to 2025. Most recent: inspection, 19 June 2025.
- Built
- 2010
- Last inspected
- 19 June 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 6 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9457024 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA2495
1103937
Flag
MALTA
—
Maury page id
psix-1103937
Inspections, by type
…with no type recorded4
Years with a record
7 calendar years (2010–2025)
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it17846 - Convention (Subpart B), Gross Ton
6796 - Convention (Subpart B), Net Ton
25130 - Dead Weight, Ton
32829 - Displacement, Ton
6796 - Convention (Subpart B), Net Ton
25130 - Dead Weight, Ton
32829 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 11
19 June 2025
COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8162658
10 May 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7445593
10 May 2022
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7447422
20 June 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6981712
30 August 2019
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6798917
12 August 2016
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5970921
24 June 2016
COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5910447
18 January 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4226686
15 January 2012
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4225523
12 January 2012
ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4222433
8 December 2010
Ballast Water Examination · ISPS II Exam · COC-CHEM Renew · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3902588
Deficiency record · 6
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 August 2019
Resolved
Associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons onboard. Fresh water generator supply piping approximately one foot after supply valve ruptured. Crew closed supply an discharge valves, but did not stop leak. Crew installed temporary patch. 74SOLAS(14)II-1/26.1
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 24 June 2016
Resolved
74 SOLAS (2004 CONS.) II-2/9.3.1. MULTIPLE PENETRATIONS WITHOUT PROPER INSULATION FOUND IN CLASS "A" BULKHEAD ON B DECK PIPE TRUNK AFTER CLASS SURVEY WAS COMPLETED. ACTION TAKEN: 50A/C.
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 January 2012
Resolved
Received inboud letter of deviation request for the secondary marine radar. 33 CFR 164.37(a)
Navigation › Collision/Grounding Avoidance › Radar
Issued 12 January 2012
Resolved
1530 - Radar - All ships of 3,000 gross tonnage and upwards shall, in addition to meeting the requirements of paragraph 2.5, have a 3GHz radar or, where considered appropriate by the Administration, a second 9 GHz radar. Master reported on eNOA that the S-Band radar was non-operational and Coast Guard issued a letter of deviation. Provide tech report. 74 SOLAS (09 cons) V/19.2.7.1
Construction/Loadline › Markings › Load Line Mark
Issued 8 December 2010
Resolved
1210-Overloading-Appropriate LL on the side corresponding to season shall not be submerged any time w/w, during voyage, or arrival. Master shall have info to arrange for loading/ballasting. VSL's plimsol mark was submerged to the f/w mark in a brackish area upon arrival to the Port of JAX, possibly an overload condition or incorrect data. ICLL 66 Part 1, Annex I Art 12
Engineering › Steering Gear System › Power Unit
Issued 8 December 2010
Resolved
0936-Steering Gear-All steering gear components shall be of sound and reliable construction. While conducting steering gear test in both local and remote control when shifting from 35 deg to opposite rudder angle the hydraulic lock alarm activated and dropped online pump and brought offline pump into service. SOLAS 74(09) II-1, reg 29.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.