SLNC PAX is a 2008 tank ship. The Coast Guard has recorded 100 inspections since 2016, most recently in July 2026, along with 255 deficiencies, 3 operational controls and 24 casualty investigations between 2014 and 2026.

Records from 2014 to 2026. Most recent: inspection, 28 July 2026.

Built
2008
Last inspected
28 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 July 2026
…with no type recorded24
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9383663
WDH3033
1103985
Flag
UNITED STATES
Maury page id
psix-1103985

Documentation record

Registered dimensions (L × B × D)315.0 ft × 62.5 ft × 34.4 ft
Registered tonnagegross 5,758 / net 2,422
ITC dimensions (L × B × D)315.0 ft × 62.5 ft × 34.4 ft
ITC tonnagegross 5,758 / net 2,422
BuilderNANTONG MINGDE HEAVY INDUSTRY CO LTD · CHINA · built 2008
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portANNAPOLIS, MD
Trade endorsementsRegistry
DocumentationValid · issued 18 November 2025 · expires 30 November 2026
Service, as the file records itTank Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5758 - Convention (Subpart B), Gross Ton
2422 - Convention (Subpart B), Net Ton
7986 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

100 inspections, each with its date, unit and type; 255 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; 24 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 100

28 July 2026 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8448455
27 July 2026 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8448453
19 June 2026 Deficiency Check · Administrative Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8408174
11 April 2026 Administrative Inspection · Periodic Inspection · MSP Periodic Oversight · Vessel Attendance · MTSA/ISPS Verification
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8349792
13 March 2026 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8325547
27 February 2026 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8317337
26 February 2026 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8318361
20 February 2026 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8313678
7 February 2026 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8307857
5 January 2026 Drydock Exam · Vessel Attendance · MSP Periodic Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8289933
10 May 2025 Annual Inspection · MTSA/ISPS Verification · MSP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8129421
23 February 2025 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8084091
3 February 2025 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8074866
13 January 2025 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8062477
30 November 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8041314
28 November 2024 Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8041518
18 November 2024 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8036171
20 October 2024 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8021656
19 October 2024 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8021650
12 October 2024 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8018004
9 October 2024 Administrative Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8018802
30 September 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8011373
29 September 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8010925
7 September 2024 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7998204
22 August 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7986872
21 August 2024 ISM Oversight · MSP Periodic Oversight · In-Service Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7982410
20 August 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7985095
20 August 2024 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7995798
28 May 2024 Administrative Inspection · Annual Inspection · MSP Annual Oversight · MTSA/ISPS Verification · Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7921208
30 April 2024 Deficiency Check · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7904250
18 April 2024 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7898007
12 April 2024 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7894001
23 March 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7883810
17 March 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7880641
6 February 2024 Administrative Inspection · MSP Periodic Oversight · Deficiency Check · In-Service Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7861228
28 December 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7842948
25 December 2023 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7842396
1 November 2023 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7818487
10 October 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7805752
5 September 2023 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7789166
20 August 2023 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7769524
10 July 2023 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7738227
22 June 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7720446
21 June 2023 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7720517
22 May 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7694505
17 May 2023 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7719655
27 March 2023 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7664367
21 March 2023 MSP COI Oversight · Administrative Inspection · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7654057
11 February 2023 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7639978
10 February 2023 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7639975
19 December 2022 Deficiency Check · Administrative Inspection · Examination of Repairs · MSP Periodic Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7602364
2 December 2022 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7603021
21 November 2022 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7597520
11 November 2022 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7609902
18 October 2022 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7579344
30 September 2022 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7569026
30 August 2022 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7548481
14 August 2022 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7535893
7 August 2022 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7591775
10 July 2022 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7558525
7 July 2022 In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7499313
26 April 2022 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7444317
11 April 2022 MSP Annual Oversight · Annual Inspection · MTSA/ISPS Verification · Administrative Inspection · ISM Oversight · Ballast Water Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7428314
21 April 2021 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7179534
12 April 2021 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7173244
5 April 2021 Administrative Inspection · MSP Annual Oversight · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7168436
10 December 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7109897
9 December 2020 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7111159
3 August 2020 ACP Drydock Oversight
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7022944
18 June 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6979803
26 April 2020 Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6943970
15 April 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6940185
27 January 2020 Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6896569
27 January 2020 Deficiency Check · MTSA/ISPS Verification · Periodic Inspection · MSP Annual Oversight
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6896572
23 January 2020 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6902994
4 July 2019 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6928323
17 April 2019 Administrative Inspection · MTSA/ISPS Verification · MSP Annual Oversight · Ballast Water Examination · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6664133
4 April 2019 Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6655550
3 April 2019 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6654836
19 March 2019 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6644960
13 February 2019 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6624897
20 November 2018 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6584467
16 October 2018 Damage Survey
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6565459
10 September 2018 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6539307
22 July 2018 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6487612
31 May 2018 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6429803
12 March 2018 Deficiency Check · Administrative Inspection · Drydock Exam · COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6369991
17 November 2017 Deficiency Check · Periodic Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6309728
21 September 2017 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6271407
29 August 2017 Damage Survey · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6255074
16 May 2017 ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6147120
19 April 2017 In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6126948
19 December 2016 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6059712
19 December 2016 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6059734
17 December 2016 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6109373
14 December 2016 ISM Oversight
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6058738
22 September 2016 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6006435
6 May 2016 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 5870219
9 April 2016 MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5837881
22 March 2016 Internal Structural Exam · Drydock Exam
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 5828903

Deficiency record · 255

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 May 2026 Resolved
The inspections mentioned in 10.2 as well as the measures referred to 10.3 should be integrated in the ships operational maintenance routine. Oil analysis report conducted on January 1, 2026 indicated the following results “CPP: “ “Rescue Boat Davit: “ Conduct comments of oil renewal, resampling and provide new oil analysis results for the review of Class and USCG.
Action required: 705 - Other - as specified
Resolved 11 June 2026
Resolution: Referred to Class and accepted as CoC for rectification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 May 2026 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Vessel had ‘LEAKAGE AT ME FUEL PIPE’ alarm blocked. Crew stated main engine injectors and fuel pumps were serviced by OEM after yard period, resulting in a fuel, source unknown (Class NK report #26EJ0214 dated March 13, 2026). MI ran main engine and noticed fuel oil leaking steadily from leak oil piping drain into casing catch and no signs of external fuel oil leaks from exposed components. Fuel oil leakage alarm read ‘Normal’ and operated satisfactory at alarm condition. Investigate fuel oil leak from internal casing and conduct repairs with servicing OEM.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 11 June 2026
Resolution: Referred to Class and accepted as CoC for rectification.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2026 Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the Organization. Vessel’s three (03) explosion proof lights on the forward bulkhead had salt water sediment in the containment indicating water intrusion. Replace three (03) lights with explosion proof rated lighting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 11 June 2026
Resolution: Referred to Class and accepted as CoC for rectification.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 May 2026 Resolved
Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position. Vessels oxygen cylinders were stowed directly on the deck and secured via a ratchet strap not in a designated rack. Move DOT cylinder into a storage bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 7 June 2026
Resolution: Received satisfactory evidence vessel fabricated/installed storage brackets for the medical oxygen bottles.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 May 2026 Resolved
The location of the controls of any valve serving a sea inlet, a discharge below the waterline or a bilge injection system shall be so sited as to allow adequate time for operation in case of influx of water to the space, having regard to the time likely to be required in order to reach and operate such controls. If the level to which the space could become flooded with the ship in the fully l Remote access valve for bow thruster space emergency bilge educator was seized open and the connection point "knuckle" is sheared at the valve stem not permitting remote activation. Replace valve and retest bilge educator operating for bow thruster space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 11 June 2026
Resolution: Referred to Class and accepted as CoC for rectification.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 7 May 2026 Resolved
Electrical installations shall be such that: electrical services essential for safety will be ensured under various emergency conditions. CO2 room ventilation local controller is inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 10 May 2026
Resolution: Attended vessel and verified operation of CO2 room ventilation controller.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 7 May 2026 Resolved
Posters or signs shall be provided on or in the vicinity of survival craft and their launching controls. During vessel’s pressure washing and exterior house maintenance, required placards postage were damaged. The master or person in charge of a ship, including a drilling rig or platform, to which this section applies shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. Replace life saving instructions for life jacket donning and survival craft operating instructions and garbage discharge placard at appropriate locations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 7 June 2026
Resolution: Received satisfactory evidence, posters for lifesaving launching and garbage placards posted.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 7 May 2026 Resolved
General arrangement plans shall be permanently exhibited for the guidance of the ship's officers, showing clearly for each deck the control stations, the various fire sections enclosed by "A" class divisions, the sections enclosed by "B" class divisions together with particulars of the fire detection and fire alarm systems, the sprinkler installation, the fire-extinguishing appliances, means of access to different compartments, decks, etc., and the ventilating system, including particulars of the fan control positions, the position of dampers and identification numbers of the ventilating fans serving each section. Fire control plan reflects deck water spray system which has been decommissioned and removed from onboard fixed fire fighting systems. Vessel utilized washroom space as a storage space for consumables. Conduct Fire Control Plan review of removed deck water spray system and space categorization for use of storage space, instead of washroom, to validate structural fire protection rating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 11 June 2026
Resolution: Referred to Class and accepted as CoC for rectification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 7 May 2026 Resolved
Test procedure documents must be in a step-by-step or checkoff list format. Each test instruction must specify equipment status, apparatus necessary to perform the tests, safety precautions, safety control and alarm setpoints, the procedure to be followed, and the expected test result. Several areas on the PSTPs did not reflect onboard testing conditions and approved testing procedures including: steering power failure alarm stated 'standby pump starts' and did not start (2-C-5), no EOT power failure alarm included in test procedure (2-A), ESTOP for boiler did not include bridge location (7-A-7), ESTOP for boiler states TMP-2 action (7-A-7), fuel oil pressure alarm for boiler states PRS-2 action (7-A-6), no ESTOP listed for fuel oil purifiers (12-A), and CPP standby hydraulic pump auto start did not have expected results from action input (4-B). Conduct full review of PSTPs Revision 6 dated February 27, 2025 for areas of discrepancies and submit for approval to Class and USCG for review and onboard verification.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 11 June 2026
Resolution: Referred to Class and accepted as CoC for rectification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 May 2026 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. The #3 auxiliary engine did not start during PSTP testing. Crew identified faulty o-ring on pneumatic starter. Crew replaced o-ring and retested the operation of the #3 auxiliary engine to the satisfaction of the attending MI.
Action required: 10 - Deficiency Rectified
Due 7 June 2026
Resolved 8 May 2026
Resolution: Crew replaced o-ring and retested the operation of the #3 auxiliary engine to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 7 May 2026 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. When testing rescue boat recovery, tube lock limit switch did not operate. Crew applied lubricant and exercised the limit switch. MI retested rescue boat launch and recovery and verified operation of limit switch.
Action required: 10 - Deficiency Rectified
Due 7 June 2026
Resolved 8 May 2026
Resolution: Crew applied lubricant and exercised the limit switch. MI retested rescue boat launch and recovery and verified operation of limit switch.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 12 May 2025 Resolved
Life-saving appliances shall at all times be in working order, ready for immediate use. 1 Rescue Boat: Secure fuel tanks, batteries not rated for marine service. 2 Lifeboat , batteries not rated for marine service.
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Due 27 May 2025
Resolved 16 June 2025
Resolution: Marine grade batteries purchased and in service, fuel tank secured.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 May 2025 Resolved
Fire protection systems shall be kept in good working order. Cargo fixed water spraying system had several clogged/blocked nozzles.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 May 2025
Resolution: nozzles removed serviced and line cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 May 2025 Resolved
Measures shall be taken by the Administration to ensure automation equipment is functional and reliable. MIs noted boiler alarms for High & low pressure and salinity are inoperable. Additionally aft safety relief valve is inhibited-needs to be serviced, sight glass missing pin for opening and closing valve.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2025
Resolution: Repaired and tested, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 May 2025 Resolved
The fire integrity of division bulkheads shall be maintained. Wire runs and telephone lines are being passed through A class boundary bulkheads without proper insulation. A60 bulkhead MCT from engine room to generator room holed and can see daylight through bulkhead allowing passage of flame and smoke.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2025
Resolution: Provided required seal of MCT penetration.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 12 May 2025 Resolved
The public address system shall be clearly audible above the ambient noise in all spaces. PA not audible IWO of EDG and CO2 rooms.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2025
Resolution: New speaker installed for PA.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 12 May 2025 Resolved
Where the atmosphere in double hull spaces cannot be reliably measured using flexible gas sampling hoses, such spaces shall be fitted with permanent gas sampling line. Pump room fixed gas monitor inaccurate, reading 21.8 O2 and 4% LEL, verified 20.8 and zero with portable instrument.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2025
Resolution: Serviced and tested, all sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 May 2025 Resolved
The venting arrangements shall be so designed and operated as to ensure that neither pressure nor vacuum in cargo tanks shall exceed design parameter. Ventilation local gauges IWO P/V Valves are out of calibration showing vacuum and inaccurate pressure on cargo tanks.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2025
Resolution: replaced with calibraded gauges, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 May 2025 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Identified 05 exterior fire hoses that were holed/ unserviceable during pressure test.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 May 2025
Resolution: Hoses replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 November 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel experienced a loss of propulsion and blackout due to actions taken after a HT alarm. Master to submit Risk Analysis and Mitigation Plan that includes statement for continued (or suspension) of PUMS continued voyage and mitigation strategy for entry into next port prior of arrival. Determine root cause of alarm condition and the reason for the lower than normal water pressure in HT tank. Make repairs to satisfaction of RO. 74 SOLAS (20) I/11(a)
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 10 December 2024
Resolution: Class surveyor provided report indicating system was operational.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 12 October 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of th present regulations to ensure that the ship in all respects will remains fit to proceed to sea without danger to the ship or persons on board. Vessels ballast treatment system has a chemical corrosion caused leak in a flange preventing the full utilization of the system. Vessel is still able to ballast and deballast as per the masters email. Make repairs to the system as per OEM and restore to full operations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2024
Resolved 14 November 2024
Resolution: Receieved tech report, BWTS fully operational.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 7 September 2024 Resolved
To assist in casualty investigations, ships, when engaged on in international voyages, subject to the provisions of regulation 1.4, shall be fitted with a voyage data recorder (VDR). It was self reported the the VDR is showing an active alarm code 18 and 22. Prior to the next port make repairs and restore the VDR to full operations. Provide a technician report to RO or USCG to attest to satisfactory operations.
Action required: 15 - Rectify deficiencies by next port
Due 8 September 2024
Resolved 9 September 2024
Resolution: The ships force CE and 1AE worked with the FURUNO reps remotely via phone and email and were able to correct the error codes. A lose CAT 5 Cable was discovered. Ships force imitated the corrective action. CAPT provided Attestation Ltr.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 28 August 2024 Resolved
Where davit arms are recovered by power, safety devices shall be fitted which will automatically cut off the power before the davit...During inspection, Marine Inspector found that all three of the limit switches were frozen due to corrosion. Additionally, it was reported that the rescue boat is overweight by 210 kg by attending OEM, lifeboat davit release gear is past due by 58 days per company SMS and rescue boat quarterly drill is also past due. Full functionality per OEM specs is required for the rescue boat and its davit. 74 SOLAS III/34 LSA Code 6.1.2.7
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 1 September 2024
Resolution: This deficiency was cleared by the attending marine inspector on 1 SEPT 2024. The condition of the ship has been verified and this outstanding deficiency has been rectified to the satisfaction of both NKK RO and USCG MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 August 2024 Resolved
Internal combustion engines of 2250 kw and above having cylinders of more than 300mm bore shall be provided with crankcase oil mist detectors or engine bearing temperature monitors or equivalent devices. Oil mist detection for the main engine is currently showing a fault. This has not caused a slowdown or shutdown of the engine, but system requires repair and to monitor the crankcase for the presence of oil mist. 74 SOLAS II-1/47.2
Action required: 10 - Deficiency Rectified
Resolved 1 September 2024
Resolution: This deficiency was cleared by the attending marine inspector on 1 SEPT 2024. The condition of the ship has been verified and this outstanding deficiency has been rectified to the satisfaction of both NKK RO and USCG MI.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 28 August 2024 Resolved
All lifesaving appliances and arrangements shall comply with the applicable requirements of the code. Each rescue boat launching appliance shall be fitted with a powered winch motor capable of raising the rescue boat from the water with its full rescue boat complement of persons...with stored mechanical energy. 74 SOLAS III/34 LSA Code 17 6.1.1.9
Action required: 10 - Deficiency Rectified
Resolved 1 September 2024
Resolution: This deficiency was cleared by the attending marine inspector on 1 SEPT 2024. The condition of the ship has been verified and this outstanding deficiency has been rectified to the satisfaction of both NKK RO and USCG MI.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - work and rest hours
Issued 28 August 2024 Resolved
Every person...must receive (1) A minimum of 10 hours of rest in any 24-hour period; and (2) 77 hours of rest in any 7-day period. While auditing work/rest recording software aboard the vessel, Marine Inspector found that several crewmembers had exceeded limits of work/rest hours per 7 days while conducting cargo operations, management reviews, and mooring/unmooring operations. Documentation attesting 07 days of proper rest periods for all crewmembers required prior to sailing. 46 CFR 15.1111(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2024
Resolution: This deficiency was cleared by the attending marine inspector on 1 SEPT 2024. The condition of the ship has been verified and this outstanding deficiency has been rectified to the satisfaction of both NKK RO and USCG MI.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 28 August 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform...to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons. Properly terminate all wiring in junction boxes and stuffing tubes. MI’s ID’d exposed wires in the following locations. Under main engine output shaft wet sump tank level indicator, smoke detector over main engine near the exhaust, generator room located ivo blue tank. 74 SOLAS 1-11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2024
Resolution: This deficiency was cleared by the attending marine inspector on 1 SEPT 2024. The condition of the ship has been verified and this outstanding deficiency has been rectified to the satisfaction of both NKK RO and USCG MI.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for personnel on tankers
Issued 28 August 2024 Resolved
Each officer or crewmember who is assigned by the PIC duties and responsibilities related to the cargo or cargo-handling equipment during a transfer of liquid cargo in bulk, but is not directly supervised by the PIC, must hold a tankerman-assistant endorsement. Vessel has an unsupervised Oiler as Pumpman who does not hold a tankerman assistant endorsement. Acting Pumpman carries out unsupervised tasks during cargo transfers without proper training.
Action required: 10 - Deficiency Rectified
Resolved 1 September 2024
Resolution: Vessel master sent a signed attestation state ment of fact stating that the pumpman will be supervised 100% of the time.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for personnel on tankers
Issued 28 August 2024 Resolved
Records of daily hours of rest must be maintained onboard the vessel. Each affected person under paragraph (a) of this section must receive a copy of the records pertaining to them, which will be endorsed by the master or by a person authorized by the master and by the seafarer. Engineers are not being tracked. 46 CFR 15.1111(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2024
Resolution: This deficiency was cleared by the attending marine inspector on 1 SEPT 2024. The condition of the ship has been verified and this outstanding deficiency has been rectified to the satisfaction of both NKK RO and USCG MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2024 Resolved
The condition of the ship and its equipment shall be maintained...in all arespects will remain fit to proceed to see without danger to the ship or persons on board. Marine inspectors received notice that the following equipment were not fully operational: start air compressor #1, ship's service air compressor, evaporator. provide evidence that all are operational. 74 SOLAS 1-11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 September 2024
Resolution: This deficiency was cleared by the attending marine inspector on 1 SEPT 2024. The condition of the ship has been verified and this outstanding deficiency has been rectified to the satisfaction of both NKK RO and USCG MI.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 28 August 2024 Resolved
Provisions shall be made to facilitate cleaning, inspection and maintenance of main propulsion and auxiliary machinery. The potable water pumps are short cycling and may need pressure switch replacement or adjustments. SOLAS II-1 26.7
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 September 2024
Resolution: This deficiency was cleared by the attending marine inspector on 1 SEPT 2024. The condition of the ship has been verified and this outstanding deficiency has been rectified to the satisfaction of both NKK RO and USCG MI.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 28 August 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. the first shot of the Port Anchor chain needs to be replaced due to numerous cracks and unsat previous repairs. SOLAS 1-11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 September 2024
Resolution: Class NKK is tracking this item and has issued a short term Saftety Construction Certificate and assinged finding numer 1123. The replacement anchor chain should arrive in the next 2 weeks prior to departure of the vessel.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 28 August 2024 Resolved
Provisions shall be made to facilitate cleaning, inspection and maintenance of main propulsion and auxiliary machinery. The hydraulic crane motor that is enclosed in the cargo hose crane pedestal has a known leak. The leak has produce approximately 700 liters of hydraulic oil being contained within the pedestal without being rectified. SOLAS II-1 26.7
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 September 2024
Resolution: This deficiency was cleared by the attending marine inspector on 1 SEPT 2024. The condition of the ship has been verified and this outstanding deficiency has been rectified to the satisfaction of both NKK RO and USCG MI.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 August 2024 Resolved
If the installed BWMS required by this subpart stops operating properly during a voyage, or the vessel's BWM method is unexpectedly unavailable...Marine inspector found that BWMS alarm history showed that, on several occasions over the previous week, the BWMS was not operating properly. Alarms included “Deballasting above MADC”, “BV-300 Purate supply valve fail to close”, and “Ballast pump running without treatment”. Additionally, during a mooring evolution while Marine Inspectors were onboard, the last “Ballast pump running without treatment” ran for over 60 minutes without being answered. Vessel must display proper functionality prior to departure. 33 CFR 151.2040(b)
Action required: 10 - Deficiency Rectified
Resolved 1 September 2024
Resolution: This deficiency was cleared by the attending marine inspector on 1 SEPT 2024. The condition of the ship has been verified and this outstanding deficiency has been rectified to the satisfaction of both NKK RO and USCG MI.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 28 August 2024 Resolved
The company is responsible for ensuring that adequate resources and shore-based support are provided to enable the designated person or persons to carry out their functions. Multiple requisitions initiated by crew are not being addressed by vessel's company. Bridge hand flares expired 01 JUL 24, Lifeboat radio batteries and the BNWAS battery is also expired. Bridge rocket flares, line throwing charges, life boat rocket flares, handflares, SART batteries, and smoke signals expire in SEP 24 and have not been ordered. There is a blatant failure at the company level utilizing NSE. Requisitions are visible within the system however, the company is failing to fulfill requisitions providing necessary supplies to the vessel. The Attending MIs were informed crewmembers that Patriot Shipping Order Staff have also been laid off. Rectify the operational-related deficiencies indicating the failure in maintaining critical items onboard SLNC PAX and share with FEACT for review by 27 OCT 2024. 74 SOLAS (20) IX/3 ISM Code A/3.3 46 CFR 4.05-1
Action required: 705 - Other - as specified
Resolved 1 September 2024
Resolution: This deficiency was cleared by the attending marine inspector on 1 SEPT 2024. The condition of the ship has been verified and this outstanding deficiency has been rectified to the satisfaction of both NKK RO and USCG MI.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 28 August 2024 Resolved
The ship’s Safety Management System (SMS) under the ISM Code (Section 9) mandates that procedures be in place to ensure that non-conformities, accidents, and hazardous situations are reported to the company, investigated, and analyzed with the objective of improving safety and pollution prevention. Attending investigating officer revealed two separate incidents that occurred but were not reported to USCG as required by regulation. 46 CFR 4.03: a marine casualty or accident includes: (ix) Reduction or loss of a vessel's electrical power, propulsion, or steering capabilities. (x) Failures or occurrences, regardless of cause, which impair any aspect of a vessel's operation, components, or cargo. 46 CFR 4.05-1: it is the responsibility of the owner, agent, master, operator, or person in charge to notify the nearest Coast Guard Marine Inspection Office immediately after addressing any resultant safety concerns. 1. The attending Investigating officer has determined that on 20 August 2024, a cargo leak occurred in the cargo pump room involving approximately 4,200 gallons of JP8 fuel into the bilge. This hazardous spill posed a significant environmental and safety risk which should have been immediately reported in compliance with 46 CFR 4.05-1 to the USCG. 2. The attending Investigating officer determined that On 16 August 2024, the ship’s deck log recorded that the ECDIS (Electronic Chart Display and Information System) halted in displaying info. Upon further questioning, the Master stated that the malfunction occurred immediately following a power loss and was restored shortly thereafter. The failure of the ECDIS system coupled with the initiating event the power loss, should have been reported as a marine casualty under 46 CFR 4.03 and 46 CFR 4.05-1. The attending Investigating Officer determined that both events constitute significant hazardous occurrences that should have been reported under the provisions of the ISM Code and US regulations. The failure to report these incidents represents a breach of both regulatory requirements and the vessel’s SMS. Rectify the shipboard procedures addressing reporting methods and notifications to appropriate parties in event of marine casualties by 27NOV2024.
Action required: 705 - Other - as specified
Resolved 1 September 2024
Resolution: This deficiency was cleared by the attending marine inspector on 1 SEPT 2024. The condition of the ship has been verified and this outstanding deficiency has been rectified to the satisfaction of both NKK RO and USCG MI.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 25 August 2024 Resolved
Provisions shall be made to facilitate cleaning, inspection and maintenance of main propulsion and auxiliary machinery. Any discharge into the sea of oil or oily mixtures from ships of 400 gross tonnage and above shall be prohibited except when all the following conditions are satisfied: the ship is proceeding en route; the oily mixture is processed through an oil filtering equipment meeting the requirements of regulation 14 of this Annex the oil content of the effluent without dilution does not exceed 15 parts per million; the oily mixture does not originate from cargo pump-room bilges on oil tankers; and the oily mixture, in case of oil tankers, is not mixed with oil cargo residues. Hydraulic valve actuator system which controls both ballast valves and cargo valves is losing 225 liters of hydraulic oil for every 8-12 hours operated. The location of this leak has not been determined which is concerning as the hydraulic lines run through both the cargo and ballast tanks. The probability exists for the contamination of the aviation fuel which has been delivered to MSC customers or the release of marine pollutants into the sea if the leak is taking place within a ballast tank. The location of this leak needs to be determined and MSC shall be made aware of a potential for recent aviation fuel contamination to protect air assets and crew. SOLAS II-1 26.7 MARPOL I/15.A.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2024
Resolution: This deficiency was cleared by the attending marine inspector on 1 SEPT 2024. The condition of the ship has been verified and this outstanding deficiency has been rectified to the satisfaction of both NKK RO and USCG MI.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 25 August 2024 Resolved
Where davit arms are recovered by power, safety devices shall be fitted which will automatically cut off the power before the davit arms reach the stops in order to prevent overstressing the falls or davits, unless the motor is designed to prevent such overstressing. During inspection, Marine Inspector found that all three of the limit switches were frozen due to corrosion. 74 SOLAS III/34 LSA Code 6.1.2.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2024
Resolution: This deficiency was cleared by the attending marine inspector on 1 SEPT 2024. The condition of the ship has been verified and this outstanding deficiency has been rectified to the satisfaction of both NKK RO and USCG MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 August 2024 Resolved
Internal combustion engines of 2250 kw and above having cylinders of more than 300mm bore shall be provided with crankcase oil mist detectors or engine bearing temperature monitors or equivalent devices. Oil mist detection for the main engine is currently showing a fault. This has not caused a slowdown or shutdown of the engine, but system requires repair and to monitor the crankcase for the presence of oil mist. 74 SOLAS II-1/47.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2024
Resolution: This deficiency was cleared by the attending marine inspector on 1 SEPT 2024. The condition of the ship has been verified and this outstanding deficiency has been rectified to the satisfaction of both NKK RO and USCG MI.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 22 August 2024 Resolved
Vessel reported that it was unable to attain a qualifed 1AE.
Action required: 10 - Deficiency Rectified
Due 1 September 2024
Resolved 2 September 2024
Resolution: a qualifed first assistant engineering reported to the vessel on 2SEP2024, prior to the vessel having to sail short.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 21 August 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without a danger to the ship or its persons on board or to the environment. Vessel is restricted from departure from Ulsan South Korea. Vessel is also prohibited cargo operations loading/discharging until further notice. This is based on concerns that have recently arisen following a discussion with MSC and the USCG. Additional information will be forthcoming in the next 24 hours.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2024
Resolved 1 September 2024
Resolution: This deficiency was cleared by the attending marine inspector on 1 SEPT 2024. The condition of the ship has been verified and this outstanding deficiency has been rectified to the satisfaction of both NKK RO and USCG MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 June 2024 Resolved
Condition of ship shall be maintained for safety to proceed to sea. During MSP Annual Oversight inspection, MIs noted numerous overdue maintenance items for vital systems and below deficiencies. Satisfactory repair plan, with identified location/port for repair/maintenance period, shall be submitted and accepted by FEACT OCMI prior to departure from Singapore. Once approved, ship shall receive authorization to proceed directly for planned maintenance and additional USCG oversight for verification of repairs once complete. 74SOLAS(2020)I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2024
Resolution: Deficiencies rectified during maintenance period in Busan, ROK
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 June 2024 Resolved
When fire-extinguishing medium (CO2) is stored outside a protected space it shall be stored in a compartment with an adequate mechanical ventilation system. MIs noted that force ventilation system for CO2 cylinder room was inoperable. Repairs to be conducted prior to departure. 74SOLAS(2020)II-2/10.4.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 June 2024 Resolved
Main and auxiliary machinery essential for propulsion and safety of the ship shall be provided with effective means for its operation and control. MIs noted failure alarms for both #1 and #2 start air compressors. Technicians were onboard attempting to service the equipment but unable to rectify prior to end of inspection. Repairs required for both compressors prior to departure. 74SOLAS(2020)II-1/31.1 25JUN2024: #2 compressor tested sat, #1 compressor (manual mode only, failed PLC for auto mode) - Amended to 15C, manned ER required.
Action required: 15 - Rectify deficiencies by next port
Resolved 18 July 2024
Resolution: Compressors tested sat and witnessed by attending class surveyor.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 21 June 2024 Resolved
Ships of 500GT and above shall comply with the ISM code for implementation of safety management system (SMS) onboard. ISM(2018) A/7 - Shipboard ops - company should establish procedures, plans, and instructions, including checklists as appropriate, for key shipboard operations. ISM(2018)A/10 - Maintenance of the ship and equipment - Company should ensure that any non-conformity is reported. Ship failed to report inoperable IGS system to USCG. RO was notified, issued condition of class o/a 14FEB2024. RO authorized 2 extensions from FEB2024 to AUG2024 w/out flag state notification or concurrence for inoperable IGS. Flag state requirements: 1. Internal SMS audit due w/in 30 days - root cause analysis into failure from management to notify USCG of IGS failure 2. Revision to cargo operation checklists which detail requirements to ensure IGS operation. As per 74SOLAS(2020)II-2/4.5.5 the subject vessel is not applicable to requirements to have an IGS onboard. Vessel management has elected to decommission the system and shall ensure all requirements are met with RO for system tag out/removal onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2024
Resolved 18 July 2024
Resolution: Company DPA attended and completed the internal audit; report is forthcoming.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for personnel on tankers
Issued 21 June 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2024
Resolved 18 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2024 Resolved
Safety of ship shall be maintained for fitness to proceed to sea. Ship's SMS overdue maintenance items shows overdue vibration analysis - overdue by approximately 2 years. Analysis shall be completed during planned maintenance period and prior to resuming cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2024 Resolved
Safety of ship shall be maintained for fitness to proceed to sea. Ship's SMS overdue maintenance items shows overdue thermography analysis - overdue by approximately 2 years. Analysis shall be completed during planned maintenance period and prior to resuming cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 June 2024 Resolved
Provisions shall be made to ensure maintenance of main propulsion machinery. Ship's SMS overdue maintenance items shows ME overhaul 11 months overdue. Satisfactory overhaul and ME maintenance items to be completed during planned maintenance period and prior to resuming cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 21 June 2024 Resolved
Ships of 500GT and above shall comply with the ISM code for implementation of safety management system (SMS) onboard. Maintenance of ship and equipment: Management shall ensure inspections are held at appropriate intervals, appropriate corrective action is taken for non-conformities, and records of these activities are maintained. Ships SMS maintenance tracking system, NSE, was out of date for most of 2024 servicing/repair items and not functional onboard. Vessel and management shall ensure that SMS maintenance tracking system is up to date and accurate onboard prior to resuming cargo operations after maintenance period.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2024 Resolved
Condition of ship and its equipment shall be maintained. Controllable pitch propeller (CPP) found with a LO sample analysis alert recommending replacement due to high iron content. Additional leaks and blocked alarms for CPP system were noted. Satisfactory repairs/oil replacement w/ maintenance due prior to cargo ops.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 June 2024 Resolved
Adequate arrangements shall be in place to ensure performance of navigation equipment. Forward anchor light discovered to be inoperable (SMS shows reports as Jan2024 w/ inop). Satisfactory replacement due.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 June 2024 Resolved
Provisions shall be made to ensure maintenance of main propulsion machinery, to include boilers. Ship's SMS shows overdue replacement of composite boiler feed water valve. 1 of 2 operational and #2 aux boiler has been permanently decommissioned. Satisfactory maintenance item to be completed during planned maintenance period and prior to resuming cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 21 June 2024 Resolved
Maintenance, testing, and inspection of lifesaving & safety gear shall be carried out. During fire drill, MIs noted SCBA pack leaking. Equipment to be tested and repaired/replaced during maintenance period.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
08 - Alarms › N/A - No Subsystem › General alarm
Issued 21 June 2024 Resolved
Condition of ship shall be maintained for safety of persons onboard. Ship's general alarm is not audible to personnel in the pumproom. GA system to be repaired/upgraded to ensure adequate coverage for emergency alarms in the pumproom during maintenance period and prior to carriage of cargo.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 17 August 2024
Resolution: Received tech report and attestation from Master.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 21 June 2024 Resolved
Condition of ship shall be maintained for safety of operations and environment onboard. #3P (95%) and #4P(98%) high and overfill alarms were inoperable. Satisfactory repairs to restore alarm function required prior to carriage of cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 June 2024 Resolved
Condition of ship and its equipment shall be maintained for safety of personnel onboard. Oxygen detection system and alarm were inoperable in the pumproom. System function shall be restored prior to cargo ops.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 June 2024 Resolved
Condition of ship shall be maintained for safety to proceed to sea and cargo operations. The following items were noted during cargo deck & superstructure/house inspection: 1. Port side manifold - Wasted MGO piping and valves corroded 2. #2 Ballast pump temp sensor electrical gland fitting loose 3. #3 Cargo pump pressure sensor fitting leaking cargo and wrapped with electrical tape 4. Electrical junction box (centerline ivo #4S tank) - corroded and holed 5. Fire main support bracked wasted (ivo #4S tank) 6. Port deck wash line bracket wasted (ivo #2P tank) 7. Vent line bracket wasted (ivo #3S tank) 8. Loose bonding strap on FM piping (ivo #2S tank) 9. Electrical cabling supports wasted & cabling unsupported (ivo port centerline fwd tanks). 10. Ballast vent piping heavily corroded throughout cargo deck on P/S sides - several screen missing or dislodged. 11. Wash connection missing bolts (ivo #4P C/T aft tank) 12. 6 sprinker leads clogged & wasted/holed (ivo #4S C/T tank). 13. Deck monitors leaking (Aft Starboard + Fwd) 14. 108 electrical room - wasted fire damper closure 15. Safety gear store room - light out 16. Starboard bridge wing - speaker mount broken Satisfactory repairs due during maintenance period and prior to cargo carriage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 June 2024 Resolved
Fire detection systems shall be kept in good working order. MIs noted improper wiring gland w/ loose wires for fire detector installed above steering gear. Satisfactory repairs due during maintenance period and prior to cargo carriage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 June 2024 Resolved
Fire protection systems shall be kept in good working order. MIs noted indication lights burned out on watermist main control panel (supply + system available indication lights). Satisfactory repairs due during maintenance period and prior to cargo carriage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 June 2024 Resolved
Safety of ship shall be maintained for fitness to proceed to sea. Ship's SMS overdue maintenance items shows overdue main safety system slow down function test. Item shall be completed during planned maintenance period and prior to resuming cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 21 June 2024 Resolved
Safety of ship shall be maintained for fitness to proceed to sea. Ship's SMS overdue maintenance items shows overdue 3-way valve replacement. Based on PM description, MIs believe this pertains to the OWS 3-way discharge valve. Further investigation by management required to determine system applicability. Item shall be completed during planned maintenance period and prior to resuming cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 21 June 2024 Resolved
Test procedure documents must be in a step-by-step or checklist format for required automation testing (PSTPs). They should specify the equipment necessary to perform the tests, alarm set points, and procedures to be followed. MIs noted the following concerns: 1. Inadequate test instructions for SSDGs, Aux Gens, and Boiler safety alarms/shutdowns 2. Missing test equipment (specifically Low LO testing) Revisions required for PSTPs and testing equipment to be provided onboard. OCMI to witness PSTPs during maintenance period and prior to cargo carriage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 June 2024 Resolved
Means shall be provided to control the leaks of flammable liquids and ignition sources limited. MIs noted leaks on CPP and ME in engine room. Satisfactory system repairs required during maintenance period and prior to cargo carriage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2024 Resolved
Measures shall be taken by the Administration to ensure automation equipment is functional and reliable. MIs noted replacement of seachest valves in lower level engine room. Remote operation for valves is installed ivo ECR (upper ER) and lines to the local valves are disonnected - no remote actuation possible. Remote function shall be restored for seachest valves as system original design. If RO does not require then FEACT OCMI requires documentation to attest to review and RO determination for documentation & acceptance.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2024 Resolved
Conditions of ship and its machinery shall be maintained. During ER inspection, MIs noted the following: 1. Improper wiring connections and glands ivo [name withheld] coolers (lower lvl ER - fwd) 2. Disconnected level/pressure sensor for CD-P Tank 3. Damaged fuel hose on ME FO gauge display (chaffing) 4. Missing manual/auto switch on sludge pump controller 5. Suspected exhaust leak on ME 6. Replacement of ME air filter 7. Fuel Oil Purifier flat - FO soaked lagging requiring replacement 8. Fuel Oil Purifier flat - inoperable emergency light 9. HFO tank level sensor missing bottom bolt - slight leak 10. Broken pull cable for manual activation of easing gear for composite boiler 11. SSDG #3 blacked out gauge Satisfactory repairs required during maintenance period and prior to cargo carriage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 21 June 2024 Resolved
An alarm system for vital system automation shall be provided. MIs noted 41 blocked alarms for automation & monitoring system onboard. Blocked alarms to be investigated and corrected as applicable during maintenance period and prior to cargo carriage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 8 February 2024 Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The safety management system should include procedures ensuring that non-conformities, accidents, and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety and pollution prevention. The company should establish procedures for implementation of corrective action, including measures intended to prevent recurrence. There is a breakdown of the onboard safety management system based on the number and severity of deficiencies, failure to report, and onboard condition of observed maintenance. Objective evidence includes: vessel has suffered failure of several critical systems and failed to report items to the vessels flag and class in accordance with shipboard SMS procedure PRO-062. Items include failure of port and starboard sea chest valves, OWS, safety MGO relief valve, lube oil purifier, and IGG. Immediate corrective actions to be completed. An external SMC audit required to be completed. 74 SOLAS 20 IX/3.1 ISM Code 18 A/10.1 ISM Code 18 A/9.1-9.2
Action required: 30 - Ship detained
Resolved 21 February 2024
Resolution: External SMC audit conducted by ABS. 08 nonconformities identified. Audit report located in the documents section of this activity.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 8 February 2024 Resolved
Each operation described in paragraph 2 of this regulation shall be completed on each occasion whenever any of the following machinery spaces operations take place in a ship. Any failure of the oil filter equipment shall be recorded in the oil record book part 1. On 6FEB2023, a failure was identified in the ships Oil Record Book. Shipboard crew placed an order under REQ#0503658 with the statement “OWS cannot run due to malfunction of PLC and HMI." This requisition was reviewed by the company purchasing manager on 13FEB23. There is no documented records to confirm if the purchase order was created or received by the vessel. A review of the ORB beyond 13FEB23 to the current date identified additional operations on 26JUN23, 18JUL23, 16AUG23 took place but no repairs were ever logged. During the attendance of the USCG on 7-8FEB24, the OWS was inoperable. Interviews with onboard crew indicated that it has been inoperable for roughly a year. There is no evidence to support a notification being made to the RO or OCMI with regard to this equipment. 78MARPOL(2017) II/17.2 and .5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2024
Resolved 21 February 2024
Resolution: PO discovered by port captain and verified by attending marine inspector. OWS was functional during attendance and verified beforehand by class NK surveyor.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 8 February 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. A crack in the port HFO fuel tank was identified by the ships force. Make repairs, NDT, and pressure test in the presence of the CG or RO prior to placing back in service. 74 SOLAS 20 I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2024
Resolution: Permanent repairs were conducted and verified by attending class surveyor.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 8 February 2024 Resolved
Every candidate for certification in advanced training for oil tanker cargo operations shall be required to: provide evidence of having achieved: the minimum knowledge, understanding and proficiency listed in column 2 of table A-V/1-1-2 and the required standard of competence in accordance with the methods for demonstrating competence and the criteria for evaluating competence tabulated in columns 3 and 4 of table A-V/1-1-2. The C/M is not properly credentialed for chemical tanker operations. STCW Part A V/1-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2024
Resolution: Vessel type changed from oil/chem carrier to Oil carrier as notated in class certificates.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 8 February 2024 Resolved
For each tankship of more than 5,000 GRT certified for voyages beyond the boundary line as described in part 7 of this chapter — At least two tankerman-engineers must be carried. The 1st A/E does not have a tankerman-engineer endorsement in accordance with table 2 to 46 CFR 15.860(a). 46 CFR 15.860(b)(3)
Action required: 705 - Other - as specified
Resolved 21 June 2024
Resolution: Cargo operations Limited to a maximum of eight (08) hours in a 24 hour period.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 February 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Emergency bilge pump is leaking salt water. In addition, the suction and discharge gauges are disconnected. 74 SOLAS 20 I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 21 February 2024
Resolution: Broken fittings repaired, witnessed and verified by class NK surveyor.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 February 2024 Resolved
The purpose of this regulation is to provide means of escape so that persons onboard can safely and swiftly escape to the lifeboat and liferaft embarkation deck. For this purpose, the following functional requirements shall be met: escape routes shall be maintained in a safe-condition. Attending MIs noted that the lighting from emergency escape trunk in the lower level engine room is extinguished. 74 SOLAS 14 II-2/13
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 9 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 February 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The ship is equipped with three air compressors, only two of which are currently working. Currently, the start air is cross connected to the working air and the control air to maintain operations. 74 SOLAS 20 I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 21 February 2024
Resolution: compressor replaced, operations testing witnessed and verified by Class NK surveyor.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 8 February 2024 Resolved
The company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. The subject vessel has an established SMS procedure for the use of NSE, but the inventory onboard doesn’t match what is on hand, including critical spares. ISM Code 18 A/7.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2024
Resolved 21 February 2024
Resolution: Identified in ABS external audit. to be addressed in vessel's corrective action plan due on 20 MAR 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2024 Resolved
Exposed metal parts of electrical machines or equipment which are not intended to be live but which are liable under fault conditions to become live shall be earthed. Bonding wires are missing or damaged throughout the cargo deck, deck lighting is showing signs of environmental intrusion within the cargo deck, and engineering space packing glands to numerous motors, controllers and lights are loose, and the fire detection head in the bosun hold is also loose. In addition, numerous junction boxes are compromised. 74 SOLAS 14 II-1/45.1.1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2024
Resolution: contractors dispatched during detnetion period to correct items. Verified by attending marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 8 February 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. The cargo deck tanks are being utilized for the storage of MGO and transferring to the engine room using the F/O stripping line without an approved fuel oil transfer plan. 74 SOLAS 20 I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2024
Resolution: HFO tank permanently repair, enabling use of cargo tank as intended. Verified by attending class NK surveyor.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 8 February 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Wastage on S/W discharge inert gas main line and tank cleaning lines leaking past the valves. 74 SOLAS 20 I/11(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2024
Resolved 21 February 2024
Resolution: Piping repaired and verified by class NK surveyor. Valves underwent satisfactory bench testing.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 February 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Ventilation louvers on the foc’sle leading to the BOSN space are wasted. 74 SOLAS 20 I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2024
Resolved 21 February 2024
Resolution: Repaired and verified by Class NK surveyor
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2024 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means that’ll be provided to control leaks of flammable liquids. Numerous fuel and lube oil leaks noted by MI, including F/O transfer pump No.1 and L/O transfer pump. CPP system oil leaking under both pumps (two catch trays are in place). Main Diesel Engine aux oil pump containment is full of oil. Lube oil purifier feed pump is leaking oil. 74 SOLAS 14 II-2/4.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 21 February 2024
Resolution: Excess oil cleaning, fittings tightened, pumps operationally tested. lube oil purifieer feed pump overhauled and reinstalled. all items verified by attnding class NK surveyor
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 8 February 2024 Resolved
In addition to the fire protection systems and appliances listed in paragraph 2.2.3, tankers shall have a maintenance plan for inert gas systems and deck foam. Attending MI’s noted that the IGG system shares a salt water line to the scrubber with the ballast system. This shared s/w connection prevents the inert gas generator and the ballast system from operating simultaneously. Additionally, the s/w supply to the IGG is leaking through wasted piping into a void space, which has caused additional equipment damage. Also, attending MI’s noted that the low expansion foam utilized for the cargo deck is past it annual testing requirements. 74 SOLAS 14 II-2/14.4
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2024
Resolution: Seawater supply repaired, IG maintenance plan currently onboard, and foam sample tested and anaylysis received. verified by class NK surveyor and reviewed by marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 February 2024 Resolved
An efficient bilge pumping system shall be provided, capable of pumping from and draining watertight compartments under all practical conditions. Numerous flexible hoses were observed tied into the installed bilge system and through the engineering spaces and are being used for management of bilge water instead of using the installed systems. 74 SOLAS 14 II-1/35-1.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 21 February 2024
Resolution: hoses removed, proper equipment installed and ready for use, verified by attending class NK surveyor.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 8 February 2024 Resolved
A means of communication shall be provided between the navigation bridge and the steering gear compartment. The sound powered phone within the steering gear space will not allow for two way communication with the bridge. 74 SOLAS 14 II-2/29.8.10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2024
Resolution: cleared by attending marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 February 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. The following deck sprinkler system, 1 P/S - no water, 2S fwd - low pressure, 2S aft - low pressure, 3P aft - no nozzle, 4S fwd - low pressure. 74 SOLAS 20 I/11(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2024
09 - Working and Living Conditions › 091 - Living Conditions › Other (food)
Issued 8 February 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Make repairs to the galley refrigeration plant in addition to the vegetable box air cooler. 74 SOLAS 20 I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2024
Resolved 22 February 2024
Resolution: Condition of class issued by class NK. Parts orders and PO created, due to arrive on vessel on/around arrival to next port of call.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 February 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Make repairs to the after industrial water pump seal. 74 SOLAS 20 I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2024
Resolved 21 February 2024
Resolution: No leak observed by ship's crew and attending class NK surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 February 2024 Resolved
Surfaces with temperatures above 220°C which may be impinged as a result of a fuel system failure shall be properly insulated. The exhaust lagging is not providing any protection on the turbo 1 aux generator. 74 SOLAS 14 II-2/2.2.6.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 21 February 2024
Resolution: Lagging readjusted and verified by attending class NK surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 February 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Numerous gauges throughout the engine room are inoperable, missing, and/or incorrectly mounted, including but not limited to the L/O feed pump, industrial pump, bilge pump, and sea water pump. 74 SOLAS 20 I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2024
Resolved 21 February 2024
Resolution: Numerous gauges replaced and calibrated. verified by attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 February 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Attending MI’s noted that the EDG exhaust is leaking at the turbo. 74 SOLAS 20 I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 21 February 2024
Resolution: No leak detected by ship's crew and attending class NK surveyor
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 February 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Restore the boiler gauge glass for the composite boiler and install the required handles for opening and closing. 74 SOLAS 20 I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 21 February 2024
Resolution: Gauge replaced and new handle installed. verified by attending marine inspector.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 8 February 2024 Resolved
The company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. Oil analysis system is showing an alert in the CPP oil system and urgent for the deck slewing crane. Complete advised actions as per company SMS procedures. ISM Code 18 A/7.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2024
Resolved 21 February 2024
Resolution: oil analysis currently onboard, crane oil changed prior to departure from Busan. identified as an ABS NC.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 February 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Repair ship's service and control air reducing stations. 74 SOLAS 20 I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2024
Resolved 21 February 2024
Resolution: Valves replaced, verified by attending class NK surveyor
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 8 February 2024 Resolved
Each officer or crewmember who is assigned by the PIC duties and responsibilities related to the cargo or cargo-handling equipment during a transfer of liquid cargo in bulk, but is not directly supervised by the PIC, must hold a tankerman-assistant endorsement. The 2/M does not hold the required endorsement on credential. 46 CFR 15.860(f)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 February 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Both port and starboard sea chest valves are inoperable / frozen.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 February 2024 Resolved
Condition of ship and its equipment shall be maintained for safety and fitness to proceed to sea. MIs noted remote actuator for sludge pump was inoperable and unable to remotely stop pump. Satisfactory repairs required. 74SOLAS(2020)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 21 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 February 2024 Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. MIs noted several missing valve handles from vital system piping controls. Valve handles required to be installed. 74SOLAS(2014)II-1/31.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2024
Resolved 21 February 2024
Resolution: contractors dispatched to replace valve handles throughout vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 February 2024 Resolved
An efficient bilge pumping system shall be provided, capable of pumping from and draining any watertight compartment. MIs noted missing hardware from bilge suction piping for starboard fwd engine room. Installation shall be corrected to restore suction protection. 74SOLAS(2014)II-1/35-1.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 21 February 2024
Resolution: hardware installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 February 2024 Resolved
Condition of ship and its equipment shall be maintained for safety and fitness to proceed to sea. MIs noted inoperable lube oil purifier. Equipment shall be repaired/replaced to restore satisfactory function. 74SOLAS(2020)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 21 February 2024
Resolution: lube oil pump overhauled and verified operation by class NK surveyor
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 8 February 2024 Resolved
Ventilation of machinery spaces shall be sufficient under normal conditions to prevent accumulation of oil vapor. MIs noted clogged and dirty engine room ventilation screens impacting sufficient ventilation. Ventilation screens shall be cleaned and restored to free condition prior to departure. 74SOLAS(2014)II-2/4.2.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2024
Resolution: dirty vents cleaned and verified by class NK surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2024 Resolved
Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical, flame-retarding and, where necessary, fire-resisting properties of the cable. MIs noted improperly terminated wires in the engine room and generator spaces. Terminated wiring shall be properly removed or connections properly made. 74SOLAS(2014)II-1/45.5.6
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 21 February 2024
Resolution: eletrical contractor dispatched to the vessel to correct deficiencies. verified by attending class NK surveyor.
01 - Certificates & Documentation › 011 - Ships Certificates › Dangerous Chemicals in Bulk (ICoF/IBC Code)
Issued 8 February 2024 Resolved
A chemical tanker shall comply with the requirements of the International Bulk Chemical Code. After any survey of the ship for compliance with the IBC code, no change shall be made in the structure, equipment, fittings, arrangement, and material covered by the survey without sanction by the Administration. Current active Certificate of Fitness (CoF), issued by ClassNK (RO), is incorrect and authorizes heat cargo carriage; Heating coils in cargo tanks are current inoperable and no longer used. RO to update vessel details and cargo limitations in issued CoF. 74SOLAS(2014)VII/10.1 IBC(2016)1.5.3.2
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2024
Resolution: Heating coils decommissioned, and notated on certificates. Vessel's ship type changed from OIL/CHEM to oil tanker and notated on RO issued certificates.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 8 February 2024 Resolved
Oil and chemical tankers of 500 GT, to include the company, shall comply with the requirements of the International Safety Management Code (ISM). The company should establish procedures to ensure that the ship is maintained. In meeting this requirement, the company should ensure that: 1. Inspections are held at appropriate intervals; 2. Any non-conformity is reported, with its possible cause, if known; 3. Appropriate corrective action is taken. MIs noted 70+ overdue maintenance tasks in the vessel's SMS system for engineering systems. Overdue tasks shall be completed and effectiveness of SMS evaluated onboard by RO (ABS) for ISM compliance. 74SOLAS(2020)IX/2.1.2 ISM(2018)A/10.1 ISM(2018)A/10.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2024
Resolution: Cleared with issuance of ABS finding associated with external audit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 February 2024 Resolved
Hydraulic power-operated steering gear shall be provided with the following: 1. Arrangements to maintain cleanliness of hydraulic fluid 3. a fixed storage tank having sufficient capacity to recharge at least 1 power actuating system including the reservoir, and shall be permanently connected by piping such that the hydraulic systems can be readily recharged. MIs noted leaking hydraulic oil from steering pumps, and missing valve handle off of the fixed storage tank for hydraulic reservoir. Fix prior to departure. 74SOLAS(2014)II-1/29.12
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2024
Resolution: Hydraulic oil cleaned from space, valve handle installed, verified by class NK surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 February 2024 Resolved
Emergency escape breathing devices (EEBDs) shall comply with the Fire Safety Systems Code (FSS) and spare devices shall be kept onboard. MIs noted EEBD ivo boiler in engine room that had zero pressure. EEBD to be replaced with satisfactory one. 74SOLAS(2014)II-2/13.3.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2024
08 - Alarms › N/A - No Subsystem › General alarm
Issued 8 February 2024 Resolved
A general emergency alarm system shall be provided. The system shall be supplemented by a public address system. The system shall be audible throughout all the accommodations and normal crew working spaces. MIs noted that the GA/PA system was not audible in spaces throughout the accommodations and on the cargo deck. Satisfactory repairs and speakers required to ensure adequate coverage of the GA/PA system. 74SOLAS(2014)III/6.4.2 74SOLAS(2014)III/6.4.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 February 2024 Resolved
Condition of ship and equipment shall be maintained for safety and fitness to proceed to sea. MIs noted; 1. Tank wash line (1S/2S) valve leaking 2. Missing hardware for #8 junction box for remote controls near fuel tanks Satisfactory repairs required. 74SOLAS(2020)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 21 February 2024
Resolution: valves pulled and seal lapped, verified by class NK surveyor
11 - Life Saving Appliances › N/A - No Subsystem › Fast Rescue Boats
Issued 8 February 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. MIs noted FRB with exhaust leak. Satisfactory repairs required. 74SOLAS(2014)III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2024
Resolution: No exhaust leak discovered by crew. Verified by class NK via op testing.
11 - Life Saving Appliances › N/A - No Subsystem › Fast Rescue Boats
Issued 8 February 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. MIs noted limit switch on rescue boat davit preventing tube locking and launching operations. Satisfactory repairs/replacement of limit switch required to restore launching function for FRB. 74SOLAS(2014)III/20.2
Action required: 10 - Deficiency Rectified
Resolved 8 February 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 February 2024 Resolved
Condition of ship and its equipment shall be maintained for safety and fitness to proceed to sea. MIs noted soft patch of gear oil pump piping. Permanent repairs to be made to defective piping. 74SOLAS(2020)I/11(a)
Action required: 10 - Deficiency Rectified
Due 9 March 2024
Resolved 21 February 2024
Resolution: Chaffing gear removed, that resembled a soft patch.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 14 April 2023 Resolved
Life-saving appliances shall be in working order and ready for immediate use. Rescue boat throttles installed incorrectly, resulting in boat going opposite of throttle labeling (ahead/astern switched).74 SOLAS (20) III/20.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2023
Resolution: Throttle cables were reversed during replacement in shipyard in January. Throttle cables were switched and operated as designed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 April 2023 Resolved
Means shall be provided to control leaks of flammable liquids. The main source of electrical power shall consist of at least two generating sets. The SSDG #3 has significant fuel oil leak on fuel return line, exhaust leak, and jacket water leak on exhaust manifold at plug. SSDG #2 and #3 generator wire casing are missing bolts and are not secured. 74 SOLAS (04) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2023
Resolution: Fuel Return line was replaced, plug in J/W manifold was replaced. Ring for exhaust was replaced. Tested Sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 14 April 2023 Resolved
Oil tankers of 150 gross tonnage and above shall be equipped with an oil discharge monitoring and control system. The ODME is not operating as designed a fails self-test with error codes for “wiper” (sensor), fresh water, and air supply.73/78 MARPOL Annex I/31
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2023
Resolution: Tech rep replaced ODME photo cell. ODME tested Sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 14 April 2023 Resolved
Oil filtering equipment installed in accordance with 73/78 MARPOL Annex I/14.1 shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. OWS was inoperable and unable to be tested.73/78 MARPOL Annex I/14.6
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2023
Resolution: OWS satisfactorily tested.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 14 April 2023 Resolved
Electrical equipment shall be of a certified safe type for use in the dangerous zones to which it may be exposed. The explosion proof lights in the paint locker have cracked covers and light on the main deck at the entrance to the paint locker has evidence of water intrusion.74 SOLAS (04) II-2/19.3.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2023
Resolution: All three lights were replaced with new. All Sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 14 April 2023 Resolved
Exposed air pipes to ballast and other tanks shall be of substantial construction and shall be provided with automatic closing devices. Multiple ventilation heads on deck are wasted, missing flame screens, or are damaged including the forward “4P WBT,” starboard lube oil tanks ventilators on starboard quarter, “5S WBT.” ILLC (88) Annex I/Reg 20
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2023
Resolution: 4P and 5S WBT flame screens replaced, Starboard lube oil tank ventilators repaired, and new screens installed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 April 2023 Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs including structural fire protection and fire-resisting divisions. Engine Room Casing door “509” does not latch shut and appears to be broken as centerline bows out while closing. 74 SOLAS (04) II-2/14.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2023
Resolution: Fire door securing device was adjusted. Door frame was found stitch welded to bulkhead and fire resisting division was found intact.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 14 April 2023 Resolved
The company should establish procedures, plans, and instructions for key shipboard operations. Test equipment provided is missing or inadequate to conduct periodic safety test procedures. Hand pump is missing required gauges for pressure indications for use during testing. 74 SOLAS (20) IX/5 ISM Code Clause 7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2023
Resolution: All equipment needed for PSTP's provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2023 Resolved
Cables and wiring shall be installed in such a manner as to avoid chafing or other damage. General Service/ Fire pump power cables into control box are missing stuffing glands. Wires are missing insulation entering “No. 5 Group Starter Panel” distribution panel. 74 SOLAS (04) II-1/45.5.5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2023
Resolution: General Service/Fire pump properly installed. No 5 Group Starter Panel wiring installed correctly.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 April 2023 Resolved
Machinery shall be adequate for the service for which it is intended and the company should ensure adequate shore based support and appropriate corrective action is taken. Working air compressor has multiple oil leaks on fittings and hoses, standing oil in interior and exterior containment around compressor, with oil-soaked sorbent pads present. Compressor fan is covered in oil and dirt. “Oil Change Due” is indicated on control panel. A replacement air compressor was removed from the December 2022 shipyard specification and these issues were documented on CG-835 issued 16Jan23 with no corrective actions taken.74 SOLAS (04) II-1/26.1 and 74 SOLAS (20) IX/5 ISM Code Clause 7 and Clause 10.2.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2023
Resolution: Compressor was completely overhauled with no apparent leaks. All Sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2023 Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chaffing or other damage. Junction box for light 5L6 in lower Engine Room is not mounted. 74 SOLAS (04) II-1/45.5.5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2023
Resolution: Juction Boxes properly mounted.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 14 April 2023 Resolved
The company should establish procedures, plans, and instructions for key shipboard operations. Periodic safety tests required by 46 CFR 61.40-6 (see NVIC 01-13, Ch. 1) must demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements, interlocks, and safety controls. Systems addressed must include fire detection and extinguishing, flooding safety, propulsion, maneuvering, electric power generation and distribution, and emergency internal communications. Revision 4A has been approved for testing with the OCMI by Marine Safety Center but required testing has not been conducted for final approval. 74 SOLAS (20) IX/5 ISM Code Clause 7 ISM Code 3.3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 April 2023
Resolution: All changes between PSTP Revision 3 and 4A were satisfactorily tested. Company to send OCMI tested procedures to MSC for final approval.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 14 April 2023 Resolved
The condition of the ship shall be maintained. The piping connecting the IG main to the PV breaker is corroded. Clean, gauge, and recoat or replace.74 SOLAS (20) I/11(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 April 2023
Resolution: PV corrosion cleaned, gauging sat, repainted.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 14 April 2023 Resolved
Access openings in bulkheads at ends of enclosed superstructures shall be weathertight when closed. Weathertight door to BWTS chemical room is installed upside down so dogs fall to open position. This item was previously identified in July 2022 and remains improperly installed.ILLC (88) Reg. 12
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 April 2023
Resolution: Dogs adjusted to fall in the closed position.
02 - Structural Conditions › N/A - No Subsystem › Safe access to tanker bows
Issued 14 April 2023 Resolved
Every tanker shall be provided with the means to enable the crew to gain safe access to the bow in accordance with MSC.62(67), Revised Guidelines for Safe Access to Tanker Bows, which requires access to be by means of either a walkway on the deck or permanently constructed gangway which should be constructed of fire resistant and non-slip material. The type approval certificate for the FRP deck grating installed on deck, raised walkways, and the cargo manifold area states “not to be used as walkways or in areas, which may be used for escape or access for firefighting, emergency operation or rescue in cargo holds and open decks or semi-enclosed areas” under ‘service restriction.’ 74 SOLAS (04) II-2/3-3.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2023
Resolved 5 July 2023
Resolution: New Galvanized Steel deck grating installed in Cargo Pump room and on safe access to bow platform.. Plan reviewed and installation overseen by Class NK.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 January 2023 Resolved
74 SOLAS (20) II-2/14.2 and ISM Code Clause 7 Fire-fighting appliances shall be kept in good working order and the company should ensure appropriate corrective action is taken to maintain the ship in conformity with provisions of relevant rules and regulations. The main fire pump is inoperable and tagged out on the main switchboard. NSE WO/SR No. 0517709 titled “Replace Fire & G/S Pump” dated June 4, 2022 indicates replacing the fire pump was to be scheduled for drydock on October 1, 2022 and was ordered per Requisition 0503411. The fire pump replacement has not been installed as of 16Jan23. Additionally, provide copy of notification made to RO (ClassNK) and USCG and provide SMS procedures for reporting marine casualties.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2023
Resolution: Accepted by ClassNK. Due by 18Feb23. Extended to 18Mar23.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 16 January 2023 Resolved
74 SOLAS (04) II-1/26.1 Machinery shall be adequate for the service for which it is intended. The WB Pump #2 has an oil leak from either the gas-tight bulkhead seal or bearing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2023
Resolution: Accepted by ClassNK. Due by 18Feb23. Extended to 18Mar23.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 16 January 2023 Resolved
74 SOLAS (04) II-1/26.1 Machinery shall be adequate for the service for which it is intended. Cargo Pump #3 has not been proven operational after maintenance and reinstallation. Provide service report and post-maintenance pressure test data.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2023
Resolution: Verified by ClassNK. See Record No. 23PS0028.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 16 January 2023 Resolved
74 SOLAS (20) IX/5 ISM Code Clause 7 and Clause 10.2.3 The company should ensure appropriate corrective action is taken to maintain the ship in conformity with provisions of the relevant rules and regulations. Independent high and overfill alarm system is not operating as designed and alarms are non-operational. The audible alarm on deck was unable to be demonstrated. The radar gauging system for cargo tanks 2P and 4P/S slops tank remain inoperable. Cargo valve actuators in COT 2P and 3P are inoperable. Port slop tank valve “COV009” has a bad solenoid. The ballast tank pressure sensors in WBT 2S, 4P, and 4S remain inoperable. Provide service reports.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2023
Resolution: Verified by ClassNK. See Record No. 23PS0028.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 16 January 2023 Resolved
74 SOLAS (20) IX/5 ISM Code Clause 7 and 74 SOLAS (20) VII/9 IBC 3.6 The company should establish instructions for key shipboard operations and provisions shall be made for the distinctive marking of pumps, valves, and pipelines to identify the service and tanks which they serve. Cargo pumps and ballast pumps, and their associated gauges, are not labeled in the Cargo Pump Room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2023
Resolution: Verified by ClassNK. See Record No. 23PS0028.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 January 2023 Resolved
74 SOLAS (04) II-1/26.1 Machinery shall be adequate for the service for which it is intended. Jacket water pre-heater selector switch is missing and heater cannot be operated locally.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2023
Resolution: Verified by ClassNK. See Record No. 23PS0028.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 January 2023 Resolved
74 SOLAS (04) II-1/26.1 Machinery shall be adequate for the service for which it is intended. Lube oil heat exchanger (plate cooler) valves have lube oil and water leaks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2023
Resolution: Verified by ClassNK. See Record No. 23PS0028.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 January 2023 Resolved
74 SOLAS (04) II-1/26.1 and 74 SOLAS (20) IX/5 ISM Code Clause 7 and Clause 10.2.3 Machinery shall be adequate for the service for which it is intended and the company should ensure adequate shore based support and appropriate corrective action is taken. Working air compressor has multiple oil leaks on fittings and hoses, standing oil in interior and exterior containment around compressor. Compressor fan is covered in oil and dirt. Additionally, several sensors/fittings are being held in place by zipties. A replacement air compressor was removed from the December 2022 shipyard specification.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2023
Resolution: Verified by ClassNK. See Record No. 23PS0028.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 January 2023 Resolved
74 SOLAS (04) II-2/4.2.2.6.1 Surfaces with temperatures above 220°C which may be impinged as a result of a fuel system failure shall be properly insulated. Insulation is degraded on SSDG #1, #2, and #3 turbochargers and need replacing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2023
Resolution: Verified by ClassNK. See Record No. 23PS0028.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 16 January 2023 Resolved
74 SOLAS (20) IX/5 ISM Code Clause 7 and Clause 10.2.3 The company should establish procedures, plans, and instructions for key shipboard operations and ensure appropriate corrective action is taken to maintain the ship in conformity with provisions of the relevant rules and regulations. Critical gauges and calibration intervals and procedures are not identified in company SMS, no standard job exists in NSE for calibration of gauges, and records of calibration available indicate no calibrations more recent than 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 January 2023
Resolution: Gauges verified by ClassNK, see Record No. 23PS0028. PRO-633 of SMS provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 January 2023 Resolved
74 SOLAS (04) II-1/26.1 Machinery shall be adequate for the service for which it is intended. The following gauges in the engine room are in need of replacement (not all inclusive): - Gauge labeled “SP Inlet” in purifier space on fuel skid is half empty and case fill is discolored indicating damage - Gauge labeled “SP #1” in purifier space on fuel skid is discolored and showing a lack of case fill indicating damage - Gauge labeled “Composite Boiler – IN” on composite boiler is half empty of case fill - Gauge on lower level of ER at gear box on port bulkhead (two sets of two gauges) lower gauge labeled “suc” is half empty of case fill; upper set not labeled, lower set labeling hard to read from deck. The following gauges in the engine room are in need of repair (not all inclusive): - Gauge labeled “Unit Outlet” in purifier space on fuel skid is being held together, or held in place, by zipties
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 January 2023
Resolution: Accepted by ClassNK. Due by 18Feb23. Extended to 18Mar23.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 January 2023 Resolved
74 SOLAS (04) II-1/26.1 Machinery shall be adequate for the service for which it is intended. The following gauges in the cargo pump room are in need of replacement (not all inclusive): - Gauges labeled with handwritten blue “1” (set of two) the left gauge is missing approximately 30% of case fill and the right gauge is missing 75% of case fill. - Gauges labeled “[?] For Cargo Pump III” (set of two) the right gauge is missing 30% of case fill and is wrapped with cloth for unknown reason. The following gauges in the cargo pump room are in need of repair (not all inclusive): - Gauges labeled with handwritten blue “1” (set of two) the right gauge is not secured and is being connected to the supply line with zipties. - Gauges labeled with handwritten pink “1” (set of two) the right gauge is secured with zipties. - Gauges on lower level port bulkhead (set of two) the right gauge is not secured.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 January 2023
Resolution: Verified by ClassNK. See Record No. 23PS0028.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 January 2023 Resolved
74 SOLAS (04) II-1/26.1 Machinery shall be adequate for the service for which it is intended. The MDE turbocharger installed is not adequate for MDE operational range. While original installation, during operational testing, the turbocharger appeared starved of air and exceeding operational parameters at 78% of MDE capability. Provide servicing report.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 January 2023
Resolution: Verified by ClassNK. See Record No. 23PS0028.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 16 January 2023 Resolved
74 SOLAS (20) V/19.2.7 and 74 SOLAS (20) IX/5 ISM Code Clause 3.3 All ships over 3,000 GT shall have a 9GHz and a 3GHz radar and the company should ensure adequate shore-based support and appropriate corrective action is taken. NSE WO/SR No 0517859 titled “Radar X-Band Check” dated June 28, 2022 conducted by the C/O indicates the X-band radar console has “issues: display very dim and hard to read during the day. Tune will drop at times especially during anchor watch. Will at times show wrong range/bearing of targets. Only fix is to reboot radar.” Marine Inspector witnessed S-Band radar screen take hours to display properly with words and numbers being illegible and lines being distorted. Replacement radars were removed from the December 2022 shipyard specification.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 January 2023
Resolution: Verified by ClassNK. See Record No. 23PS0028.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 January 2023 Resolved
74 SOLAS (20) III/20.3 Maintenance, testing and inspections of life-saving appliances shall be carried out in a manner having due regard to ensuring reliability of such appliances. Extensive corrosion is evident on rescue boat davit. The December 2022 yard specification indicated the rescue boat davit needs to be pressure washed and coating renewed. The five yearly servicing was completed and many wasted components were replaced but the blasting and coating were not completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 February 2023
Resolution: Rec'd photo from vsl.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 16 January 2023 Resolved
74 SOLAS (20) IX/5 ISM Code Clause 7 and Clause 10.2.3 The company should establish procedures, plans, and instructions for key shipboard operations. Maximum Allowable Working Pressure (MAWP) for cargo system not indicated in SMS. Approved drawing M1-4331 “Cargo Loading/Unloading & Stripping Sys” indicate working pressure is 10 bar. Provide SMS document outlining MAWP and 1.5x test pressure with cargo piping hydrostatic test certificate. Alternately, provide cargo piping hydrostatic test certificate with test pressures in accordance with parameters on approved drawings.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 January 2023
Resolution: Verified by ClassNK. See Record No. 23PS0028.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 September 2022 Resolved
The machinery shall be adequate for the service for which it is intended. After several hours of running, No. 1 Diesel Generator was reported to shutdown without notice while under load.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2022
Resolved 6 September 2022
Resolution: Accepted by Nippon Kaiji Kyokai Class No. 089711, Record number 22TZ1369.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 7 July 2022 Resolved
The ship and its equipment shall be maintained. The cargo control monitoring system is not operating as designed: 1- Bjorge monitoring and control system console 'X102' is inoperable due to CPU failure. Discharge pressures and bearing temperatures are unavailable in the cargo control room and must be taken manually at manifold or on console 'X101' in engine control room. 2- the independent radar gauging system computer shows unidentified intermittent alarm for cargo tank 3P indicating 98-99% full. Standing alarm dated 07July2022 while the tank was empty and gas-free. 3- ECR Bjorge "Cargo Tank" screen indicates all cargo tanks and 'Deck Tank S' are full while all cargo tanks are empty and gas-free. 4- high and overfill alarms for 'Slop Tank S' were found inhibited due to faulty sensor in need of repair. Engine Control Room and Cargo Control room shall be manned for the duration of transfer operations and adequate communication ensured. 74 SOLAS I/11(a) MARPOL Annex I/6.4.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2022
Resolved 7 August 2022
Resolution: Accepted by ClassNK. Extended due to inability of comopany to get technician into country due to visa requirements.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 24 May 2022 Resolved
The company and the ship shall comply with the requirements of the International Safety Management code, to include establishment of procedures to ensure the ship is maintained with regulations & appropriate corrective action is taken upon non-conformity reports. The following cargo systems non-conformities were reported with no follow up from the company. 1-Cargo pump #3 mechanical seal leak- work order (SR 0515190) open since NOV 2021, with "near miss" report for hazardous condition filed by ship's Captain on 14MAY2022 with no rectification or servicing arrangements by management. Cargo pump #3 is prohibited from use until approved repairs. 2-Pump room bulkhead hyd penetration leaks from fittings reported via 4 open work orders & report from 19APR2022. 3-Alarm intermittent issue with overfill audio alarms on deck & corroded speaker system and supporting bracket failing submitted 01MAY2022. Immediate corrective actions to be completed. External SMC audit required to be completed focused on ISM maintenance and procedures & corrective actions implementation by company. CITE: 74 SOLAS (2020) IX/3.1 ISM Code (2018) 10.1 ISM Code (2018) 10.2.3 Updated 17JUN2022: Company appeal to OCMI regarding external SMC audit requirement was granted in part. Requirement for additional external SMC audit removed. Flag instructions to be provided to ABS regarding maintenance/corrective action implementation by management as focus areas for upcoming intermediate SMC audit. FEACT MIs to attend audit. Secondary appeal for extension of material condition repairs granted, items extended to 24JUL2022 for final repair in Busan, ROK. Update 23JUN2022: Extended to 24AUG2022 for final repair in Busan, ROK. Pump restricted from use until repaired and verified by ClassNK.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2022
Resolved 10 June 2022
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 24 May 2022 Resolved
Conditions of the ship shall be maintained to ensure it remains fit for sea without danger to it or persons onboard. Marine Inspector noted substantial corrosion & wastage to sprinkler piping, electrical conduit piping for control/sensor cabling, and air lines in way of cargo tank 3P hatch. Conduct repairs to suspect & defective piping. CITE-74 SOLAS (2020) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2022
Resolved 10 June 2022
Resolution: Verified by Class NK surveyor
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 May 2022 Resolved
Ventilators passing through superstructures shall have substantially constructed coamings of steel. Marine Inspectors noted corroded deck vent, port side in the changing/laundry room. Conduct satisfactory repairs to ventilator. CITE - ICCL (2005)19(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2022
Resolved 10 June 2022
Resolution: Verified by attending ClassNK surveyor
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 24 May 2022 Resolved
Performance of navigational equipment shall be maintained. Magnetic compass experiencing deviations in excess of 5 degrees at multiple headings. Conduct satisfactory servicing/adjustment of compass. CITE - 74 SOLAS (2020) V/16.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2022
Resolved 10 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 24 May 2022 Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out in a manner with due regard to ensure reliability of such appliances. Rescue boat search and position lights are not wired IAW schematic, fuse is bypassed. Conduct repairs IAW approved drawings. CITE - 74 SOLAS (2004) III/20.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2022
Resolved 10 June 2022
08 - Alarms › N/A - No Subsystem › Boiler alarm
Issued 24 May 2022 Resolved
Each oil-fired boiler shall have safety arrangements which shut-off the fuel supply or flame failure. Composite boiler does not shut-off on flame failure. CITE - 74 SOLAS (2004) II-1 Reg 32.2
Action required: 705 - Other - as specified
Resolved 10 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 April 2022 Resolved
Machinery and associated pipings systems, and fittings shall be of a design and construction adequate for the service which they are intended. The following items were noted by Marine inspectors: 1-Two pipe flanges on the Main Engine Lube Oil cooler system found leaking. 2-Discharge elbow on the Inert Gas System raw water pump is holed from corrosion. 3-Failed Aux Salt Water supply pipe to Evaporator has been replaced with flex hose and hose clamps. CITE - 74 SOLAS (2004) II-1/26.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2022
Resolved 10 June 2022
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 5 April 2021 Resolved
Fire-fighter’s outfits shall comply with the Fire Safety Systems Code - Personal equipment shall consist of the following: axe with a handle provided with high-voltage insulation. All four fire fighter outfits did not have an axe as required. 74 SOLAS (14)II-2/10.1.1 FSS Code 2.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 April 2021
Resolution: See Class Record No. 21SS0088 uploaded to Documents.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 5 April 2021 Resolved
The automatic stopping device is a device used, where applicable, to automatically stop any discharge overboard of oily mixture when the oil content of the effluent exceeds 15 ppm. The automatic stopping device should consist of a valve arrangement installed in the effluent outlet line of the 15 ppm Bilge Separator which automatically diverts the effluent mixture from being discharged overboard back to the ship’s bilges or bilge tank when the oil content of the effluent exceeds 15 ppm. The valve arrangement installed to automatically divert the effluent mixture overboard or back to the ships bilges does not function rendering the oil filtering equipment inoperable. Repair or replace with new, and test to the satisfaction of Class. MARPOL Annex I/14.7 MEPC 107(49)/3.6
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 April 2021
Resolution: See Class Record No. 21SS0088 uploaded to Documents.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 April 2021 Resolved
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. The foam service and general service fire pumps priming system are not installed as manufactured and inoperable. Install in accordance with manufacturer’s procedures and test to the satisfaction of Class. 74 SOLAS (14)I/1.b
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 9 June 2021
Resolution: See Class Survey No. 21PS0451 uploaded to Documents.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 5 April 2021 Resolved
The engine shall be capable of operating when the lifeboat is flooded up to the center line of the crankshaft. During underway operations, the rescue boat experienced excessive smoke in the engine compartment because of engine contact with accumulated water in the bilge that was well below the center line of the crankshaft. 74 SOLAS (14)III/34 LSA Code 4.4.6.4
Action required: 10 - Deficiency Rectified
Resolved 5 April 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 April 2021 Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Wasted wire supports for electrical cables located on the starboard side house exterior directly below and in way of rescue boat deck. Sections of the electrical cables are detached from the exterior bulkhead. Replace wire supports with new to the satisfaction of Class.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 30 May 2021
Resolution: See Class Survey No. 21PS0451 uploaded to Documents.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 5 April 2021 Resolved
Means shall be provided to drain all cargo pumps and all oil lines at the completion of cargo discharge, where necessary by connection to a stripping device. The line and pump draining shall be capable of being discharged both ashore and to a cargo tank or a slop tank. For discharge ashore a special small diameter line shall be provided and shall be connected outboard of the ship's manifold valves. No. 2 cargo pump stripping line in cargo pump room discovered with unapproved soft patch. Prior to use for stripping operations, make permanent repairs to line and test to the satisfaction of Class.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 30 May 2021
Resolution: See Class Survey No. 21PS0451 uploaded to Documents.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 February 2020 Resolved
74 SOLAS (04) Chapter II-1/Part A-1, Reg.3-1, ICLL66 Reg. 12: In addition to the requirements contained elsewhere in the present regulation, ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society. WTD 48 fails to close properly to prevent water from entering space and hosptal space WTD with wastage. Replace with new/repair to the satisfaction of Class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2020
Resolution: See Class NK report CLB of repairs carried out.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 16 February 2020 Resolved
74 SOLAS (04) Chap II-1/43.2: The electrical power available shall be sufficient to supply all those services that are essential for safety and in an emergency, due regard being paid to such services as may have to be operated simultaneously. The emergency generator jacket water was leaking excessively upon start up at the engine pre-heater. Repair jacket water leak and prove proper operation to the satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2020
Resolution: EDG jacket water leak was repaired by crew and tested with no further leaks.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 16 February 2020 Resolved
74 SOLAS(09) Chapter II-2/14.2.1.1: The following fire protection system shall be kept in good order so as to ensure their required performance if a fire occurs. The sprinkler heads in the IGG room was clogged with debris. Remove sprinkler heads and clear debris to the satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2020
Resolution: Crew removed debris from sprinkler heads in IGG room and was reinspected to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 February 2020 Resolved
74 SOLAS(09) Chapter II-2/5.2.1.1: The main inlets and outlets of all ventilation systems shall be capable of being closed from outside of the spaces being ventilated. The means of closing shall be easily accessible as well as prominently and permanently marked. The ventilation closures for emergency diesel generator room, inert gas generator room, crew lounge, and galley vents were seized and corroded. The galley vent screen on aft poop deck was wasted. Repair and demonstrate proper operation of ventilation closures.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2020
Resolution: Witnessed ventilation closures excercised by crew and used chalk test to verify proper seal.
08 - Alarms › N/A - No Subsystem › Inert gas alarm
Issued 16 February 2020 Resolved
74 SOLAS(09) Chapter II-2/4.5.5.1.2, FSS Code Reg 15 Paragraph 2.4.3.1: Tankers operating with a tank cleaning procedure with a tank cleaning procedure shall be fitted with an inert gas systems complying with the Fire Safety Systems Code and with fixed tank washing machines. For inert gas systems of both the flue gas type and inert generator type, audible and visual alarms shall be provided. The IGG alarm panel in Cargo Control Room did not alarm during auto shut down tests. Repair and demonstrate proper operation of IGG alarms.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2020
Resolution: Witnessed satisfactory test of cargo alarms in CCR.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 16 February 2020 Resolved
74 SOLAS (09) Chapter II-2/4.5.5.1.2, FSS Code Reg 15 Paragraph 2.1.2: Tankers operating with a tank cleaning procedure with a tank cleaning procedure shall be fitted with an inert gas systems complying with the Fire Safety Systems Code and with fixed tank washing machines. The inert gas systems refer to Chapter II-2 of the Convention shall be designed, constructed and tested to the satisfaction of the Administration. The IGG flame window glass is cracked. Replace glass to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2020
Resolution: See Class NK report CLB of repairs carried out.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2020 Resolved
74 SOLAS (04) Chapter II-1/40.1.3: Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. Multiple dead end wire runs from the upper engine room to the lower engine room between cargo pumps No. 1 & 2. Remove dead end wire to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2020
Resolution: See Class NK report CLB of repairs carried out.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 16 February 2020 Resolved
74 SOLAS (04) Chapter II-1/3-1: In addition to the requirements contained elsewhere in the present regulation, ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society. The air diaphragm pump discharge gauge in cargo pump room lower flat is broken and unserviceable. Replace with new in-kind gauge to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2020
Resolution: See Class NK report CLB of repairs carried out.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2020 Resolved
74 SOLAS(04) Chapter II-1/40.1.3: Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. Found all electrical motors grounding cables in lower engine room not grounded or missing.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2020
Resolution: See Class NK Form CLB of repair carried out.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 16 February 2020 Resolved
74 SOLAS (04) Chapter II-1/46: Every ship shall be provided with documentary evidence, to the satisfaction of the Administration, of its fitness to operate with periodically unattended machinery spaces. PSTP for 12-B-1 Remoted Fuel oil Valves shutoffs are incorrect. The fuel valves group and number on PSTP are missing. The placard for the remote fuel valves group outside the engine room does not match with the local fuel valves group down in the engine room. Prove proper test procedure to the satisfaction of Class.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 16 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 February 2020 Resolved
74 SOLAS (04) Chapter II-1/3-1: In addition to the requirements contained elsewhere in the present regulation, ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society. The main engine’s oil leak off piping behind the governor was disconnected and rigged with a hose, reclaiming the engine oil back into the main engine sump through the sounding tube. Vessel shall provide procedure to Class for review and determination.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2020
Resolution: See Class NK report CLB of repairs carried out.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 16 February 2020 Resolved
74 SOLAS (04) Chapter II-1/46: Every ship shall be provided with documentary evidence, to the satisfaction of the Administration, of its fitness to operate with periodically unattended machinery spaces. PSTP for 12-A-1 Remote Electrical Shutoffs for Fans and Pumps are incorrect. The electrical breakers listed on the PSTP does not match the actual electrical breakers on the switchboard and electrical breaker reset sheet. Prove proper test procedure to the satisfaction of Class.
Action required: 705 - Other - as specified
Resolved 16 August 2020
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 16 February 2020 Resolved
74 SOLAS(04) Chapter II-1/3-1: In addition to the requirements contained elsewhere in the present regulation, ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society. The deck in way of provision WTD 428 severely wasted with holes. Repair to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2020
Resolution: See Class NK report ATT of repairs carried out.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 February 2020 Resolved
74 SOLAS (04) Chapter II-1/3-1: In addition to the requirements contained elsewhere in the present regulation, ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society. Handrails with wastage and holes behind emergency engine room and aft stairwell in poop deck. Repair to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2020
Resolution: See Class NK report CLB of repairs carried out.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 February 2020 Resolved
74Solas(04) Chapter II-1/3-1 In addition to the requirements contained elsewhere in the present regulation, ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society. Port and starboard cargo manifold stanchion support base is severely wasted. Replace to original and to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2020
Resolution: See Class NK report CLB of repairs carried out.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 16 February 2020 Resolved
74 SOLAS (04) Chapter II-1/3-1: In addition to the requirements contained elsewhere in the present regulation, ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society. Port and starboard side Pilot’s embarkation safety chains are severely wasted and unusable. Replace to original and to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2020
Resolution: See Class NK report CLB of repairs carried out.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 February 2020 Resolved
74 SOLAS (09) Chapter II-2/7.1: The purpose of this regulation is to detect fire in the space of origin and to provide for alarm for safe escape and fire-fighting activity. The optical smoke detector in the hospital space is inoperable. Repair and prove proper operation to the satisfaction of Class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2020
Resolution: See Class NK report CLB of repairs carried out.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 16 February 2020 Resolved
The placard sign for the Cargo Pump Room was missing and could not be found by the crew. The CG-835V, will be revised to OSHA standards for shipboard operations per Title 29, Code of Federal Regulations, Part 1915.16, Subpart B: The Employer shall ensure that each sign or label posted to comply with the requirements of this subpart is presented in a manner that can be perceived and understood by all employees,
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2020
Resolution: See Class NK report CLB of repairs carried out.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 16 February 2020 Resolved
MARPOL Annex 1. Chapter 2 Reg 6.4: An annual survey within three months after each anniversary date of the Certificate including the general inspection of the structure, equipment, systems, fittings, arrangements and material refer to (1.1) of this regulation to ensure that they have been maintained in accordance with paragraphs 4.1 and 4.2 of this regulation and that they remain satisfactory for the service which the ship is intended. Found discrepancy on the IOPP for bilge tank capacity did not match Tank Capacity Plan DWG Number B1-0301. The IOPP indicates 9 m3 and Tank Capacity Plan drawing states 29.7 m3. Required verification from Class Society.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2020
Resolution: See Class NK report CLB of repairs carried out.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 February 2020 Resolved
74 SOLAS (14) Chapter III/20.2: Before ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. The free fall life boat beacon light is inoperable and the engine fuel filter maintenance was not completed. Replace inoperable beacon light with new and complete life boat maintenance to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2020
Resolution: See Class NK report CLB of repairs carried out.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 16 February 2020 Resolved
74 SOLAS (09) Chapter II-2/15.2.4: General arrangement plan shall be permanently exhibited for the guidance of the ships officers clearly for each deck control stations, the various fire sections enclosed by A divisions, the sections enclosed by B divisions together with particulars of the fire detection and fire alarm systems. The fire control symbols in galley for fire dampers are faded and unreadable. Replace with new fire dampers placards in accordance with the approved fire control plan to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2020
Resolution: See Class NK report CLB of repairs carried out.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 16 February 2020 Resolved
74 SOLAS (14) Chapter III/20.7.2: Inspection of lifesaving appliances, including lifeboat equipment, shall be carried out monthly using the checklist required by regulation 36.1 to ensure that they are complete and in good order. The rescue boat’s portable fire extinguisher is severely wasted and unserviceable. Replace with new in-kind portable fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 February 2020
Resolution: New portable fire extinguisher inspected in rescue boat to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 February 2020 Resolved
74 SOLAS(04) Chapter II-1/26.1: The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which it is intended and so installed and protected as to reduce to a minimum and danger to persons onboard due regard being paid to moving parts, hot surfaces and other hazards. The number one generator’s’ jacket water hose was cracked and dry rotted. Replace jacket water hose to the satisfaction of the Coast Guard.
Action required: 10 - Deficiency Rectified
Resolved 17 February 2020
Resolution: Jacket water hose replaced with new to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 February 2020 Resolved
46 CFR 147.60: Cylinders must always be secured when not in use. They must be stored in the upright position with the valve protection cap in place. Lockers and housing must be vented to the open air near the top and bottom for positive circulation of vapors. Cylinders must be protected all sources of heat which may cause the cylinders to be heated to a temperature higher than 130 degree Fahrenheit. Acetylene compressed bottles stowed in the IGG fan room, an unapproved storage for compressed gases. Relocated compressed bottles to a designated locker or housing for proper stowage.
Action required: 10 - Deficiency Rectified
Resolved 17 February 2020
Resolution: Compressed cylinders removed from IGG Room to proper storage or removed off the ship.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 May 2019 Resolved
Replace bridge pyrotechnic flares that are not USCG approved. 46CFR160.036-4
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 May 2019
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 6 May 2019 Resolved
Replace port embarkation adder and replace polypropylene line for stbd poop deck life buoy. SOLAS III/11.7 LSA Code 6.1.6
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 May 2019
Resolution: Corrected.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 6 May 2019 Resolved
Replace wasted butterlfy valve for the port aft No. 4 foam monitor fire station. SOLAS II-2/4.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 May 2019
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 6 May 2019 Resolved
Main water supply valve for the high pressure water mist system was found closed. SOLAS II-2/14.2.1.1.2
Action required: 10 - Deficiency Rectified
Resolved 6 May 2019
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 May 2019 Resolved
Remove oily residue found below the shaft generator. SOLAS II-2/4.2.4
Action required: 10 - Deficiency Rectified
Resolved 6 May 2019
Resolution: Corrected.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Operational procedures for engines or equipment
Issued 6 May 2019 Resolved
Update the foam room procedures for step No. 5 to read, "start the foam monitor pump." SOLAS II-2/4.2
Action required: 10 - Deficiency Rectified
Resolved 6 May 2019
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2019 Resolved
Secure loose high pressure CO2 cylinder in the CO2 room. SOLAS 1/11(a)
Action required: 10 - Deficiency Rectified
Resolved 6 May 2019
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 September 2018 Resolved
Vessel's port box cooler sustained a leak. Make permanent repairs to include gauging to ensure no additional wastage. To the satisfaction of USCG ACTIVITIES FAR EAST
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 September 2018
Resolved 17 October 2018
Resolution: Corrected.
Documentation › Certificates/Documents › Certificate of Fitness (BCH Code)
Issued 3 May 2018 Resolved
Vessel does not meet MARPOL ANNEX I Regulation 28(6) for approved damage computer. Vessel is restricted to F76, JP5, JP8, and MOGAS and must load vessel in accordance with KG/GM values and righting arm curves under approved NK laoding manual dated 31JAN14 and damage stability manual dated 15MAY14. Reference USCG letter dated 03MAY18. DEF CODE 01130
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 July 2018
Resolved 22 July 2018
Resolution: Updated class approved loading manual into MISLE. Also updated new IOPP, COF and class report attesting to witnessing satisfactory review of damage stability computer. All Sat.
Operations/Management › Vessel Activity › Other
Issued 3 May 2018 Resolved
Main Engine, Fire pump, Foam Pump, and start air inoperable. Bring online and test satisfactory with USCG present. Def Code 99102
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2018
Resolved 3 May 2018
Resolution: USCG MI verified all operational. All Sat.
Operations/Management › Vessel Activity › Other
Issued 3 May 2018 Resolved
Prepare vessel to be safe for sea. Replace international shore connection in proper location, remove ties/tarps on life rafts, remove wires across ventilation, replace grating in pump room, and clear waste and clutter from deck and engineering spaces. DEF CODE 99102
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2018
Resolved 3 May 2018
Resolution: USCG MI witnessed vessel ready for sea. All Sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 3 May 2018 Resolved
Cargo pump room strainer is leaking excessively. DEF CODE 14105
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2018
Resolved 3 May 2018
Resolution: USCG MI witnessed pump does not leak anymore. Replaced gasket. All Sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 3 May 2018 Resolved
Remove bags from CO2 nozzles in engine room after servicing. DEF CODE 07110
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 3 May 2018
Resolved 3 May 2018
Resolution: USCG MI witnessed removal of bags from CO2 nozzles. All Sat.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 3 May 2018 Resolved
04 nozzles on main deck spray system were fully or partially clogged. Repair or replace. DEF CODE: 07110
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 3 May 2018
Resolved 3 May 2018
Resolution: USCG MI witness retesting of deck water spray system to include 04 nozzles that were blocked. All Sat.
Fire Fighting › Fire Hoses › Condition
Issued 3 May 2018 Resolved
02 fire hoses failed pressure test. Repair or replace. DEF CODE: 07124
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2018
Resolved 3 May 2018
Resolution: C/M replaced 02 fire hoses w/new hose. All Sat.
Fire Fighting › Fire Hoses › Material
Issued 3 May 2018 Resolved
01 fire nozzle failed. Repair or replace. DEF CODE:07124
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2018
Resolved 3 May 2018
Resolution: C/M replaced nozzle w/ new nozzle. All Sat.
Operations/Management › Vessel Activity › Other
Issued 3 May 2018 Resolved
LIghting missing/inoperable in the following spaces: bow thruster room, engine room, outboard of the house, and pump room. DEF CODE: 09108
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 3 May 2018
Resolved 3 May 2018
Resolution: C/M replaced all missing lights w/ lights.
Operations/Management › Vessel Activity › Other
Issued 3 May 2018 Resolved
Dead-end wires exposed in pump room. Remove wire. DEF CODE: 09109
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 3 May 2018
Resolved 3 May 2018
Resolution: C/E removed dead end wire in Pump room. All Sat.
Lifesaving › Rescue Boat › Markings
Issued 3 May 2018 Resolved
Rescue boat retroreflective tape faded. Repalce w/SOLAS approved tape. DEF CODE: 11135
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2018
Resolved 3 May 2018
Resolution: C/M replaced the retroreflective tape. All Sat.
Operations/Management › Vessel Activity › Other
Issued 3 May 2018 Resolved
Lagging missing throughout engine room, purifier room, stack and A-deck. DEF CODE: 13199
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2018
Resolved 3 May 2018
Resolution: C/E replaced missing lagging throughout engine room, purifier room, stack and A-deck. All Sat.
Operations/Management › Vessel Activity › Other
Issued 3 May 2018 Resolved
Repair damaged lagging throughout engine room. DEF CODE:13199
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2018
Resolved 25 May 2018
Resolution: Recieved updated pictures of the repaired lagging. All Sat.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 3 May 2018 Resolved
03 pressure gauges on pressure vessels are inoperable. Repair or replace. DEF CODE:99101
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2018
Resolved 31 May 2018
Resolution: All three gauges were replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 May 2018 Resolved
Wire penetration throughout engine control room are missing flame/smoke resistant fitting. DEF CODE: 07103
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2018
Resolved 3 May 2018
Resolution: C/E plugged missing cable penetrations w/ CG approved material. All Sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 3 May 2018 Resolved
Portable fire extinguisher in IGG room is not USCG approved. Replace w/ USCG approved or replacement in kind. DEF CODE: 07110
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2018
Resolved 3 May 2018
Resolution: C/M replaced fire extinguisher w/spare one onboard. Replacement in kind approved under GAP Analysis. All Sat.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 15 September 2017 Resolved
Submit to OCMI a repair proposal for permanent repair of Port Slop Tank and boundary with No. 4 WBT prior to conducting repair.
Due 27 April 2018
Resolved 25 April 2018
Resolution: Vessel submitted repair proposal to OCMI and approved repair w/ NK and MI present.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 15 September 2017 Resolved
Conduct repair on Port Slop Tank and boundary with No 4 WBT in accordance with OCMI approved repair proposal.
Due 27 April 2018
Resolved 25 April 2018
Resolution: Reviewed sat repair as per the repair proposal w/ NK and MI present. All Sat.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 30 August 2017 Resolved
Conduct daily soundings of all cargo, slop, and ballast tanks and report any negative changes in ship stability to Sector Guam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 15 September 2017
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 30 August 2017 Resolved
Have a Marine Chemist certify the 4P WBT and 4P Slop Tanks "Safe for Workers" to allow the class society surveyor and CG MI entry while in Guam.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 September 2017
Resolved 15 September 2017
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 30 August 2017 Resolved
Schedule ship's class society to attend vessel while in Guam to assess/identify the source of sea water intrusion into the 4P Slop Tank.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 September 2017
Resolved 15 September 2017
Engineering › Generator (propulsion/auxiliary-electric) › Bus
Issued 22 June 2017 Resolved
Determine cause of No 3 generator which tripped off line and caused a black out.
Action required: 705 - Other - as specified
Due 21 September 2017
Resolved 21 September 2017
Resolution: Vessel replaced parts and had no issues. Two tech reps confirmed.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 22 June 2017 Resolved
Remove boiler shut-down as marked on engine control console.
Due 22 July 2017
Resolved 26 June 2017
Resolution: Old shutdowns removed.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 22 June 2017 Resolved
Renew vapor control drain valves so they are operable.
Due 22 July 2017
Resolved 11 July 2017
Resolution: Valves replaced
Communications › Alarms/Indicators › Fire Alarm
Issued 22 June 2017 Resolved
Inoperable audible horn inside fuel oil purifier room.
Due 22 June 2017
Resolved 22 June 2017
Resolution: Horn works.
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 22 June 2017 Resolved
Replace wasted shackles for liferaft ladder on port side.
Due 22 June 2017
Resolved 22 June 2017
Resolution: Shackles replaced.
Construction/Loadline › Hull › Bottom Plating
Issued 16 May 2017 Resolved
Submit to OCMI a repair proposal for permanent repair of Starboard Slop Tank and boundary with No. 4 WBT prior to conducting repair.
Due 18 May 2018
Resolved 25 April 2018
Resolution: Reviewed repair proposal submitted to OCMI and approved repair based on NK/MI present.
Construction/Loadline › Hull › Bottom Plating
Issued 16 May 2017 Resolved
Conduct repair on Starboard Slop Tank and boundary with No 4 WBT in accordance with OCMI approved repair proposal.
Due 18 May 2018
Resolved 25 April 2018
Resolution: Reviewed repair based on repair proposal w/ NK and MI present. All Sat.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 16 May 2017 Resolved
Approved Periodic Safety Test Procedure (PSTP):Complete review and submit for approval to Marine Safety Center (MSC) automation test procedure that demonstrates proper operation of machinery to include testing procedures & set points. After satisfactory review by MSC PSTP must be verified and approved by OCMI prior to vessel operating either PUMS or MAMS.
Action required: 705 - Other - as specified
Resolved 22 June 2017
Resolution: Completed testing of MSC Reviewed Revision 2. Pen and ink changes made. Approved copy must include changes until MSC reviews Revision 3.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 16 May 2017 Resolved
Several bonding straps broken off in pump room and throughout vessel.
Due 22 July 2017
Resolved 26 June 2017
Resolution: Bonding straps replaced
Construction/Loadline › Hull › Weld
Issued 19 December 2016 Resolved
Submit a permanent repair proposal to this office and the repair proposal must be approved prior to conducting permanent repair on Starboard Slop Tank and boundary with No. 4 WBT.
Condition: Improper/Lack of Maintenance
Due 15 May 2018
Resolved 16 May 2017
Resolution: Deficiency cancelled and reissued as two separate 835's for clarification.
Construction/Loadline › Hull › Bottom Plating
Issued 19 December 2016 Resolved
Identify and submit a monitoring system on the clad welded area as well as other areas noted for heavy pitting in the bottom plating and the lowest portion of the corrugated bulkhead.
Condition: Improper/Lack of Maintenance
Due 28 January 2017
Resolved 13 January 2017
Resolution: Recieved monitoring program from the Port Engineer [name withheld] The vessel made a map of 13 noted pitted areas. Since the heavy pitted areas are inside the slop tank. Continously monitoring the area will be difficult. Uploaded proposal to MISLE.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 3 October 2016 Resolved
"Fire Hazard-Cargo pump room: Upon entry into the cargo pump room, strong benzene odor was observed. Upon closer exam, it was discovered the deck is saturated with product. Observed #3 cargo pump leaking product at approximately 5 drops per second. Asked Chief Mate to test air quality with dragger and Benzene was identified. See Narrative for full deficiency.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2016
Resolution: Resolved to satisfaction of class.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 3 October 2016 Resolved
Routine maintenance items of deck and machinery equipment are overdue as per ships computerized maintenance program (NS5). Over 60 items identified on the Machinery side…deck side estimated to have 40 items. Complete external audit of the vessel SMS and the vessel maintenance program regarding the overdue items. Audit shall be completed to the satisfaction of the OCMI
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 14 December 2016
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 3 October 2016 Resolved
Approved Periodic Safety Test Procedure. Complete review and submit for approval automation test procedure to demonstrate proper operation of machinery to include testing procedures and set points. Multiple systems to include the boiler and steering could not be tested to the current PSTP.
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 17 May 2017
Resolution: Item reissued with clarified verbiage in MISLE Activity 6147120
Documentation › Certificates/Documents › Engine IAPP Certificate
Issued 3 October 2016 Resolved
EIAPP certificate for the SDG is missing and could not be confirm. Provided EIAPP cert of the three generators on board.
Due 15 November 2016
Resolved 13 October 2016
Resolution: EIAPP for generators located.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 22 September 2016 Resolved
PSTP must demonstrate proper operation of the test. Boiler safety on repeater panel could not be demonstrated on the bridge or any other stations. Technician worked on the systems 2 days earlier and system is now inoperative. Complete repair to the boiler safety and provide technician report. Engine room watch shall be fully manned until proper operation of the boiler safeties can be demonstrated.
Action required: 705 - Other - as specified
Resolved 25 October 2016
Resolution: Complete to satisfaction of class report.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 22 September 2016 Resolved
Make repair to the A-60 boundary IWO engine room emergency escape trunk.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 3 November 2016
Resolution: Cleared by Class
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 September 2016 Resolved
Lighting in the E/R escape trunk is inoperable…02 bulbs are blown. Replace light broke light bulbs and complete to the satisfaction of the OCMI.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 3 October 2016
Resolution: Light was fixed and verified by CGMI
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 22 September 2016 Resolved
Fire hazard: Bilges contain extensive amounts of oil from main and auxiliary machinery. Bilge coated with long standing dirt/oil mixture coming from SSDE and MDE; oil soaked rags & debris in bilges well under engines. Clean excess oily bilge in the E/R.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 3 November 2016
Resolution: Cleared by Class
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 22 September 2016 Resolved
Engine space-Purifier Room: Excess oily deck, oily rags and oil soaked lagging presents a fire hazard. Clean purifier room to the satisfaction of the OCMI.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 14 December 2016
Fire Fighting › Combustible Materials › Insulation
Issued 22 September 2016 Resolved
Engine space-Purifier Room-fire hazard: Replace oil soaked lagging/insulation to the satisfaction of the OCMI.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 25 December 2016
Resolution: Recieved class report from NKK. Cleared deficiency from activity and uploaded class report to MISLE.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 22 September 2016 Resolved
Replace oil soaked fire extinguisher in the E/R at station 41. Replacement extinguisher shall be USCG approved.
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 6 October 2016
Resolution: 3RD MATE CLEANED
Fire Fighting › Combustible Materials › Insulation
Issued 22 September 2016 Resolved
Fire hazard: Main Engine is leaking exhaust and damaging lagging/insulation and associated piping. Complete repair to the satisfaction of the OCMI.
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 3 November 2016
Resolution: Cleared by Class
Fire Fighting › Combustible Materials › Insulation
Issued 22 September 2016 Resolved
Fire hazard: NO 2 Generator is leaking exhaust and damaging lagging/insulation of the associated piping. Complete repair to the satisfaction of the OCMI.
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 14 December 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 September 2016 Resolved
Replace missing and damaged steam pipe insulation in the E/R.
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 14 December 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 September 2016 Resolved
Replace missing and damage exhaust lagging on the N01, No2 and No3 Ship service generators.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 25 December 2016
Resolution: Recieved report from Class attending the repairs to the satisfaction of class surveyor [name withheld] and cleared 835.
Electrical › Electrical Distribution System (service) › Switch
Issued 22 September 2016 Resolved
Repair exposed electrical contact relay switch in the purifier room.
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 7 October 2016
Resolution: SWITCH AND WIRING WAS REMOVED FROM SERVICE. SWITCH IS ONLY USED FOR VALVE POSITION INDICATOR INSIDE
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 22 September 2016 Resolved
Complete repair to the fractured exhaust bracket on the No 2 ships generator.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 25 October 2016
Resolution: Satisfaction of Class.
Deck/Cargo › Cargo Heating › General
Issued 22 September 2016 Resolved
Renew cargo steam lines. The lines are rusted beyond serviceability.
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 14 December 2016
Engineering › Steam Boiler (auxiliary/waste heat) › Water Level Indicator
Issued 22 September 2016 Resolved
Make repair to the aux boiler. Boiler is inoperative due to bad water level relay switch. After repair, complete automation test of the aux boiler and ensure automation is with standard with PUMS.
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 3 November 2016
Resolution: Cleared by Class
Deck/Cargo › Inert Gas System › Venting System
Issued 22 September 2016 Resolved
Make repair/adjustment to the ventilation closure louver to the IGG. The louver will not remain in close position after closure.
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 25 October 2016
Resolution: Complete to satisfaction of Class.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 22 September 2016 Resolved
Make repair to the GA2 alarm remote control station. The alarm panel box rusted and no longer weather tight.
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 3 November 2016
Resolution: BOX IS PATCHED., RFQ 1001480 FOR NEW BOX.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 22 September 2016 Resolved
Make repair to the wasted E-Gen exhaust stack.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 14 October 2016
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 22 September 2016 Resolved
E-generator: Remove excess rust behind ventilation screen and ensure the ventilation door able to be close and seal.
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 3 November 2016
Resolution: Cleared by Class
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 22 September 2016 Resolved
Dispose of portable flammable gas outside the poop deck. The bottle had rusted beyond service life.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 6 October 2016
Resolution: DRILLED HOLE IN EMPTY RUSTY OXYGEN BOTTLE 2016-10-06
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 22 September 2016 Resolved
Repair ground out of the No3 cargo pump. During testing of the ESD, the pump ground out on the main panel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2016
Resolved 14 October 2016
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 22 September 2016 Resolved
Repair radio control box near Life Boat to ensure weather tight.
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 25 October 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 22 September 2016 Resolved
Replace light bulbs in inoperable flood-lights throughout vessel deck.
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 3 November 2016
Resolution: Cleared by Class
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 22 September 2016 Resolved
Replace faded rescue boat placard with readable placard.
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 25 October 2016
Stability › Watertight Integrity › Weathertight Enclosure
Issued 22 September 2016 Resolved
Adjust weather tight door on boat deck near chief mate’s stateroom to seal properly.
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 15 October 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 22 September 2016 Resolved
Mount and repair light fixture in the battery room.
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 15 October 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 22 September 2016 Resolved
Repair light fixtures in safety store room.
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 15 October 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 22 September 2016 Resolved
Mount and repair light fixture in the No. 2 and No. 3 diesel generator room.
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 15 October 2016
Fire Fighting › Ventilation Systems › Ducts
Issued 22 September 2016 Resolved
Repair main laundry dryer vent lines to exit the space, clean excessive lint build up.
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 15 October 2016
Fire Fighting › Ventilation Systems › Ducts
Issued 22 September 2016 Resolved
Repair side laundry room dryer vent to allow unobstructed passage of air.
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 15 October 2016
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 9 April 2016 Resolved
The vessel is not sufficiently manned to maintain satisfactory material condition, sufficient maintenance and effective security. Within sixty days the minimum safe manning will be corrected adding an additional AB and an additional Oiler. Or, within thirty days, the company may propose alternative corrective action for OCMI evaluation. Proposal must address maintenance, manning, work hours, carg
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 June 2016
Resolved 26 April 2016
Resolution: PCS provided alternative corrective action. Evaluated and approved. FEACT will verify effectiveness by 10OCT2016.

Casualty record · 24

7 July 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4950759
26 October 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5023626
6 November 2015Routine · role: Involved in a Marine Casualty · activity 5762648
13 November 2015Routine · role: Involved in a Marine Casualty · activity 5763947
17 December 2016Routine · role: Involved in a Marine Casualty · activity 6109373
4 July 2019Routine · role: Involved in a Marine Casualty · activity 6928323
9 December 2020Routine · role: Involved in a Marine Casualty · activity 7111159
26 April 2022Routine · role: Involved in a Marine Casualty · activity 7444317
10 July 2022Routine · role: Involved in a Marine Casualty · activity 7558525
7 August 2022Routine · role: Involved in a Marine Casualty · activity 7591775
11 November 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7609902
10 February 2023Routine · role: Involved in a Marine Casualty · activity 7639975
27 March 2023Routine · role: Involved in a Marine Casualty · activity 7664367
17 May 2023Routine · role: Involved in a Marine Casualty · activity 7719655
21 June 2023Routine · role: Involved in a Marine Casualty · activity 7720517
5 September 2023Routine · role: Involved in a Marine Casualty · activity 7789166
20 August 2024Routine · role: Involved in a Marine Casualty · activity 7995798
19 October 2024Routine · role: Involved in a Marine Casualty · activity 8021650
20 October 2024Routine · role: Involved in a Marine Casualty · activity 8021656
28 November 2024Routine · role: Involved in a Marine Casualty · activity 8041518
23 February 2025Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8084091
20 February 2026Routine · role: Involved in a Marine Casualty · activity 8313678
26 February 2026Routine · role: Involved in a Marine Casualty · activity 8318361
27 July 2026Routine · role: Involved in a Marine Casualty · activity 8448453
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.