SELECAO is a 2008 tank ship. The Coast Guard has recorded 13 inspections since 2017, most recently in April 2026, along with 5 deficiencies and 1 operational control.
Records from 2017 to 2026. Most recent: inspection, 14 April 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it41676 - Convention (Subpart B), Gross Ton 41676 - Simplified, Gross Ton 21792 - Convention (Subpart B), Net Ton 88225 - Displacement, Metric Ton 21792 - Simplified, Net Ton 74296 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 13
14 April 2026PSC B · COC-TVE Annual
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8344828
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 January 2019Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Ship's crew failed to remove the metal blocking piece after testing the H.F.O. SERV. TK TO M/E & G/E F.O. SUPPLY P/P quick closing valve on 03DEC2018. Ship continued to utilize HFO with the metal blocking piece in place until switching over to low sulphur fuel on 25DEC2018. In the event of an engine room fire, the quick closing valve would not be able to fully close as designed and HFO would continue to be supplied potentially supporting the fire in the space. The remote actuator for the valve would be ineffective.
Action required: 30 - Ship detained
Due 22 January 2019
Resolved 23 January 2019
Resolution: Class report submitted attesting to the rectification of noted deficiency.
Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation. The arrangement on board ship for the extraction of samples from the 15 ppm Bilge Separator discharge line to the 15 ppm Bilge Alarm should give a truly representative sample of the effluent with an adequate pressure and flow. Due to the missing seal on the sample line as required by the Company, PSCO had the crew secure the sample line by means of two manual valves preventing oil content meter from processing a true sample of effluent. PSCO observed the oily water separator continually process effluent overboard (overboard simulation valve) for over 5 minutes without adequate pressure and flow to the oil content meter. PSCO observed no alarms or any redirection of effluent.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 January 2019
Resolved 23 January 2019
Resolution: Class report submitted attesting to the rectification of noted deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 22 January 2019Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. An immersion suit shall be constructed with waterproof materials such that: it can be unpacked and donned without assistance within 2 min, taking into account donning of any associated clothing, donning a lifejacket if the immersion suit is to be worn in conjunction with a lifejacket to meet the requirements of paragraph 2.3.1.2, and inflation of orally inflatable chambers. PSCOs observed 04 crewmembers don the immersion suit to include the lifejackets. Only 01 crewmember was able to don the immersion suit within the required timeframe.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2019
Resolved 23 January 2019
Resolution: Class report submitted attesting to the rectification of noted deficiency.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 22 January 2019Resolved
The company and the ship shall comply with the requirements of the ISM Code. The company should clearly define and document the master's responsibility with regard to implementing the safety and environmental-protection policy of the company. The ISM Company's "Standard Operating Procedure on Oily Water Separator" item 2.2.vii requires a seal that would break if the manual sample line valves were closed. PSCO observed no seals in place for the sample line valves as per Company policy. With no alarm arrangements or mechanism in place to ensure the OCM will analyze the actual effluent at all times when operational, securing the sample line valves in the open positions is critical to avoid willful manipulation of the OCM.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2019
Resolved 23 January 2019
Resolution: Class report submitted attesting to the rectification of noted deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 22 January 2019Resolved
A tank vessel with a capacity of 250 or more barrels that is carrying oil or hazardous material as cargo must have on board an emergency means to enable the person in charge of a transfer operation to a facility, to another vessel, or within the vessel to stop the flow of oil or hazardous material. All the cargo pumps were running during the test of the emergency shutdown from the port side manifold. After the ESD was engaged (initial test), the #3 cargo pump continued to run with no alarms or trips.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 January 2019
Resolution: Class report submitted attesting to the rectification of noted deficiency.