LV LIZZY is a 2008 tank ship. The Coast Guard has recorded 19 inspections since 2016, most recently in July 2026, along with 3 deficiencies and 2 operational controls.
Records from 2016 to 2026. Most recent: inspection, 21 July 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it43797 - Convention (Subpart B), Gross Ton 21967 - Convention (Subpart B), Net Ton 74998 - Dead Weight, Metric Ton 89773 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
19 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 19
21 July 2026COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8443187
18 June 2026Deficiency Check · PSC B · In-Service Inspection
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 18 June 2026Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
PSCO observed a cracked 10 foot section of bunker line on deck.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2026
Resolved 28 July 2026
Resolution: Class survey submitted, def written to satisfaction of class.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 9 June 2026Resolved
The protection of the cargo tanks shall be achieved by a fixed inert gas system in accordance with the requirements of the Fire Safety Systems Code. At least two inert gas blowers shall be fitted & capable of delivering to the cargo tanks at least the volume of gas required paragraph 2.2.1.2. While testing the IG system, PSCO observed the #1 blower repeatedly shutting down due to an unknown reason. vessel is permitted to discharge remaining cargo not to exceed 3000m3/hr in accordance with 125% of the rated capacity of the #2 blower. Vessel is required to have a fully functional IG system prior to departure from the USCG Sector Corpus Christi COTP zone.
74SOLAS(20) II-2/4.5.5.1.1
FSS Code 15.2.3.1.4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2026
Resolution: Class attended the vessel and attested to the proper repairs of the #1 blower.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 May 2024Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions against such risks shall be taken to the satisfaction of the Administration. In cargo pump room, PSCO observed 07 explosion proof fixtures that had exposed wiring and lacked gas-tight integrity, with 01 casing that was cracked.
74 SOLAS (04) II-1/45.5.4
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2024
Resolution: Vessel submitted class survey report attesting to the completion of the repairs. See report in documents.