BF TIMARU is a 2006 freight ship. The Coast Guard has recorded 13 inspections since 2016, most recently in January 2022, along with 8 deficiencies and 1 operational control.
Records from 2016 to 2022. Most recent: inspection, 13 January 2022.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it11142 - Dead Weight, Ton 15617 - Displacement, Ton 8407 - Convention (Subpart B), Gross Ton 4215 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 January 2022Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed lube oil leak on #2 SSDG and accumulation of oil and rags around engine room. 74SOLAS(20) II-2//4.1.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 January 2022
Resolution: Class surveyor attended vsl and L/O lines were tighted to #2 DG, and DG tested with no leaks present. General cleanliness of engine room was improved and cleaned.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 January 2022Resolved
The construction of doors and doors frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to the fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. PSCO observed self-closing door to escape trunk pinned open and unable to close completely. 74 SOLAS (20) II-2/9.4.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2022
Resolution: Class attended vsl and self-closing mechanism for the escape trunk door was repaired. Door in compliance and resistant to smoke and fire confirmed by class surveyor.
Every ship shall have a garbage management plan that provides procedures for the storage of garbage onboard which the crew shall follow. PSCO's observed approximately 40 full garbage bags stored in a machinery space below the main deck, not in accordance with the plan.
73/78 MARPOL (17) V/10.2
17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 September 2021
Resolved 18 September 2021
Resolution: Received, reviewed and accepted class report from NK (class) stating deficiency was rectified.
Vessel coordinated trash removal through a waste removal service to remove all garbage.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 September 2021Resolved
Testing of fire-fighting systems and appliances shall be carried out based on the guidelines developed by the Organization. PSCO's observed crew member attempt to test a flame detector using an open flame cigarette lighter. Crew was unable to produce procedures authorizing open flame lighters as an approval testing device.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2021
Resolved 17 October 2021
Resolution: Documents received from ship rectifying deficiency. Deficiency issued by Sector Houston Act# 7314314.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 August 2021Resolved
MEANS SHALL BE PROVIDED WHEREBY NORMAL OPERATION OF PROPULSION MACHINERY CAN BE SUSTAINED OR RESTORED EVEN THOUGH ON OF THE ESSENTIAL AUXILIARIES BECOMES INOPERATIVE. SPECIAL CONSIDERATION SHALL BE GIVEN TO THE MALFUNCTION OF THE SOURCES OF WATER PRESSURE. PSCO OBSERVED PORT AND STARBOARD COOLING INTAKE SEA WATER PIPING CORRODED BEYOND REPAIR. THIS PIPING PROVIDES COOLING WATER FOR ALL MACHINERY ONBOARD.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2021
Resolution: Deficiency is cleared. Repairs were conducted and approved by class.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 August 2021Resolved
FIRE-FIGTHING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED 02 CO2 BOTTLES IN THE CO2 ROOM WHERE INSTALLED INCORRECTLY RESULTING IN THE HOSE BEING KINKED AND SHOWED SIGNS OF CRACKING.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2021
Resolution: Hoses were replaced and installed. Deficiency rectified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 December 2020Resolved
Vessel's Master opeerating in the waters of the United States must ensure the removal of fouling organisms from vessel's hull, and dispose substances in accordance with local, state, and federal laws. Port State Control Officer identified excessive marine growth on the entirety of the vessel's hull waterline.
33 CFR 151.2050(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2020
Resolved 24 December 2020
Resolution: Reviewed diving documentation supporting biofouling control performed.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 27 November 2020Resolved
Emergency fire pump for ship shall be maintained ready for use. Emergency fire pump was not ready for immediate use after 60 minutes.
PSCO observed adequate pressure from emergency fire pump.
74 SOLAS Cons. 14 II-2/12.1.1
Action required: 10 - Deficiency Rectified
Due 3 December 2020
Resolved 3 December 2020
Resolution: PSCO observed adequate pressure from emergency fire pump prior to departing vessel inspection.